Assessment of Efficacy of Implant Screwdrivers' During Multiple Tightening/ Untightening Cycles. An in vitro Study.

IF 1.1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
R Batista, A Moreira, N Alves, M H Figueiral, J C Sampaio-Fernandes
{"title":"Assessment of Efficacy of Implant Screwdrivers' During Multiple Tightening/ Untightening Cycles. An in vitro Study.","authors":"R Batista, A Moreira, N Alves, M H Figueiral, J C Sampaio-Fernandes","doi":"10.1922/EJPRD_2743Batista09","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>It is unclear the number of times a screwdriver may be reused without loosening its efficacy or inducing damage to implant screws while keeping appropriate torque values.</p><p><strong>Objective: </strong>Evaluate the effect of the screwdriver and internal threads on the tightening efficacy by assessing the reverse torque value (RTV).</p><p><strong>Methods: </strong>The efficacy was tested with four groups of screws: two titanium groups and two gold-platted (n=5). Each screw was tightened 10 times at 20 Ncm using the screwdriver attached to ISD900 (NSK®). In the first protocol one implant was used for the five screws. In the second protocol for each screw a new implant was used. At each untightening, the RTV was measured and recorded.</p><p><strong>Results: </strong>RTVs for Gold were statistically lower compared to the Titanium. The RTVs differed among the tested screws. In the first protocol, the first serie tightening/untightening differed statistically from the last three series.</p><p><strong>Conclusion: </strong>Titanium screws from Zimmer Biomet achieve better RTV than gold-platted. By increasing the number cycles it is expected to have a decrease in the RTV. The extensive use of screwdrivers and the internal threads of the dental implants might be factors influencing the loss of RTV.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2743Batista09","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: It is unclear the number of times a screwdriver may be reused without loosening its efficacy or inducing damage to implant screws while keeping appropriate torque values.

Objective: Evaluate the effect of the screwdriver and internal threads on the tightening efficacy by assessing the reverse torque value (RTV).

Methods: The efficacy was tested with four groups of screws: two titanium groups and two gold-platted (n=5). Each screw was tightened 10 times at 20 Ncm using the screwdriver attached to ISD900 (NSK®). In the first protocol one implant was used for the five screws. In the second protocol for each screw a new implant was used. At each untightening, the RTV was measured and recorded.

Results: RTVs for Gold were statistically lower compared to the Titanium. The RTVs differed among the tested screws. In the first protocol, the first serie tightening/untightening differed statistically from the last three series.

Conclusion: Titanium screws from Zimmer Biomet achieve better RTV than gold-platted. By increasing the number cycles it is expected to have a decrease in the RTV. The extensive use of screwdrivers and the internal threads of the dental implants might be factors influencing the loss of RTV.

种植体螺丝刀在多次拧紧/松开周期中的有效性评估。体外研究。
简介:在保持适当的扭矩值的情况下,螺丝刀可以重复使用多少次,而不会松动其功效或导致植入螺钉损坏,目前尚不清楚。目的:通过评估反向扭矩值(RTV),评价螺丝刀和内螺纹对螺钉拧紧效果的影响。方法:采用4组螺钉:2组钛螺钉和2组镀金螺钉(n=5)进行疗效观察。使用ISD900 (NSK®)上的螺丝刀在20ncm处拧紧每颗螺钉10次。在第一个方案中,五个螺钉使用一个植入物。在第二个方案中,每个螺钉使用一个新的植入物。每次放松时,测量并记录RTV。结果:金的rtv低于钛的rtv。被测螺钉的rtv不同。在第一个方案中,第一个系列的拧紧/松开与后三个系列有统计学差异。结论:Zimmer Biomet公司钛合金螺钉的RTV优于镀金螺钉。通过增加循环次数,预计RTV会下降。螺丝刀的广泛使用和种植体的内螺纹可能是影响RTV丧失的因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信