Effect of Fiber Reinforcement on the Flexural Strength of Long-Span, 3D-Printed, Interim Fixed Dental Prosthesis.

Suphansa Sivakorn, Richard Lin, Cheryl Park
{"title":"Effect of Fiber Reinforcement on the Flexural Strength of Long-Span, 3D-Printed, Interim Fixed Dental Prosthesis.","authors":"Suphansa Sivakorn, Richard Lin, Cheryl Park","doi":"10.11607/ijp.9203","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To inspect the impact of polyethylene fiber (Ribbond) on the long-span, 3D-printed, interim fixed dental prosthesis regarding fracture strength.</p><p><strong>Materials and methods: </strong>A stainless steel platform was fabricated to replicate the partial edentulism for a maxillary four-unit fixed dental prosthesis. The prosthesis was fabricated by a Formlabs SLA 3D printer. The specimens were allocated into four groups of 20 each: experimental reinforced Group A (prosthesis with a slot reinforced with fiber); experimental Group B (prosthesis with a slot filled with 3D-printed material), negative control Group C (prosthesis with a slot); and control Group D (full-contour prosthesis). Fracture strength exams were performed with a universal tester. The fracture patterns were examined. A statistical analysis was conducted using one-way ANOVA and Tukey HSD test.</p><p><strong>Results: </strong>The control group exhibited a significantly higher mean flexural load (D: 306.32 ± 50.76 N) compared to the other groups (A: 194.37 ± 68.02 N; B: 178.25 ± 42.67 N; and C: 156.68 ± 29.73 N; [P < .001]). No differences were identified among Groups A, B, and C. The fracture pattern differed between the nonreinforced Groups B, C, and D and reinforced Group A, with catastrophic failure observed in the nonreinforced group and unseparated failure observed in the reinforced group.</p><p><strong>Conclusions: </strong>The study findings demonstrate that the incorporation of Ribbond in 3D-printed, interim fixed dental prostheses does not significantly enhance their fracture strength. However, it does lead to a noticeable change in the fracture behavior, shifting from a complete failure to an incomplete fracture pattern.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-8"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To inspect the impact of polyethylene fiber (Ribbond) on the long-span, 3D-printed, interim fixed dental prosthesis regarding fracture strength.

Materials and methods: A stainless steel platform was fabricated to replicate the partial edentulism for a maxillary four-unit fixed dental prosthesis. The prosthesis was fabricated by a Formlabs SLA 3D printer. The specimens were allocated into four groups of 20 each: experimental reinforced Group A (prosthesis with a slot reinforced with fiber); experimental Group B (prosthesis with a slot filled with 3D-printed material), negative control Group C (prosthesis with a slot); and control Group D (full-contour prosthesis). Fracture strength exams were performed with a universal tester. The fracture patterns were examined. A statistical analysis was conducted using one-way ANOVA and Tukey HSD test.

Results: The control group exhibited a significantly higher mean flexural load (D: 306.32 ± 50.76 N) compared to the other groups (A: 194.37 ± 68.02 N; B: 178.25 ± 42.67 N; and C: 156.68 ± 29.73 N; [P < .001]). No differences were identified among Groups A, B, and C. The fracture pattern differed between the nonreinforced Groups B, C, and D and reinforced Group A, with catastrophic failure observed in the nonreinforced group and unseparated failure observed in the reinforced group.

Conclusions: The study findings demonstrate that the incorporation of Ribbond in 3D-printed, interim fixed dental prostheses does not significantly enhance their fracture strength. However, it does lead to a noticeable change in the fracture behavior, shifting from a complete failure to an incomplete fracture pattern.

纤维增强对大跨度3d打印临时固定义齿抗弯强度的影响。
目的:观察聚乙烯纤维(带状)对大跨度3d打印临时固定义齿断裂强度的影响。材料与方法:制作不锈钢平台复制上颌四单元固定义齿的局部全牙。该假体由Formlabs SLA 3D打印机制造。将标本分为4组,每组20只:实验加固A组(带纤维加固槽的假体);实验组B组(带槽填充3d打印材料的假体),阴性对照组C组(带槽假体);对照组D组(全轮廓假体)。断裂强度测试用通用测试仪进行。检查了断裂模式。统计学分析采用单因素方差分析和Tukey HSD检验。结果:对照组的平均弯曲负荷(D: 306.32±50.76 N)明显高于其他各组(a: 194.37±68.02 N;B: 178.25±42.67 n;C: 156.68±29.73 N;[p < .001])。在A、B、C组之间没有发现差异。未加筋的B、C、D组与加筋的A组之间的骨折模式不同,未加筋组观察到灾难性的断裂,而加筋组观察到未分离的断裂。结论:本研究结果表明,在3d打印的中期固定义齿中掺入Ribbond并没有显著提高义齿的断裂强度。然而,它确实会导致裂缝行为的明显变化,从完全断裂转变为不完全断裂模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信