Investigation of artificial intelligence-based clinical decision support system's performance in reducing the fine needle aspiration rate of thyroid nodules: A pilot study.

IF 0.8 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Amy Barnes, Rebecca White, Heather Venables, Vincent Lam, Ram Vaidhyanath
{"title":"Investigation of artificial intelligence-based clinical decision support system's performance in reducing the fine needle aspiration rate of thyroid nodules: A pilot study.","authors":"Amy Barnes, Rebecca White, Heather Venables, Vincent Lam, Ram Vaidhyanath","doi":"10.1177/1742271X241299220","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This pilot study aims to evaluate the clinical impact of artificial intelligence-based decision support, Koios Decision Support™, on the diagnostic performance of ultrasound assessment of thyroid nodules, and as a result to avoid fine needle aspiration.</p><p><strong>Methods: </strong>This retrospective pilot study was conducted on ultrasound images of thyroid nodules investigated with fine needle aspiration from January 2022 to December 2022. Orthogonal ultrasound images of thyroid nodules, previously investigated with fine needle aspiration, were compared with the Koios Decision Support™ suggestion to perform fine needle aspiration. Surgical histology was used as ground truth.</p><p><strong>Results: </strong>A total of 29 patients (76% women) with a mean age of 48 ± 16.5 years were evaluated, <i>n</i> = 15 (52%) were histologically proven benign and <i>n</i> = 14 (48%) were malignant. In the benign group, Koios Decision Support™ suggested avoidable fine needle aspiration in <i>n</i> = 8 (53%). In the malignant group, Koios Decision Support™ suggested follow-up or no fine needle aspiration in <i>n</i> = 2 (14%). Sensitivity is 85.7% (<i>n</i> = 12) (<i>p</i> = 0.027), whereas specificity is 53.3% (<i>n</i> = 8) (<i>p</i> = 0.027). The positive predictive value is 63.2% (<i>n</i> = 12), negative predictive value is 80% (<i>n</i> = 8), false-negative value is 20% (<i>n</i> = 2) and false-positive value is 36.8% (<i>n</i> = 7). Based on artificial intelligence decision, one cancer would have been missed.</p><p><strong>Conclusion: </strong>Artificial intelligence can improve specificity without significantly compromising sensitivity. There was a suggested reduction in the fine needle aspiration rate, in the histologically proven benign nodules, by 53%. This had no statistical significance, likely due to the small population, however, it is thought to be the largest study to date. Further investigation with wider-ranging studies is suggested.</p>","PeriodicalId":23440,"journal":{"name":"Ultrasound","volume":" ","pages":"1742271X241299220"},"PeriodicalIF":0.8000,"publicationDate":"2024-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11625399/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1742271X241299220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: This pilot study aims to evaluate the clinical impact of artificial intelligence-based decision support, Koios Decision Support™, on the diagnostic performance of ultrasound assessment of thyroid nodules, and as a result to avoid fine needle aspiration.

Methods: This retrospective pilot study was conducted on ultrasound images of thyroid nodules investigated with fine needle aspiration from January 2022 to December 2022. Orthogonal ultrasound images of thyroid nodules, previously investigated with fine needle aspiration, were compared with the Koios Decision Support™ suggestion to perform fine needle aspiration. Surgical histology was used as ground truth.

Results: A total of 29 patients (76% women) with a mean age of 48 ± 16.5 years were evaluated, n = 15 (52%) were histologically proven benign and n = 14 (48%) were malignant. In the benign group, Koios Decision Support™ suggested avoidable fine needle aspiration in n = 8 (53%). In the malignant group, Koios Decision Support™ suggested follow-up or no fine needle aspiration in n = 2 (14%). Sensitivity is 85.7% (n = 12) (p = 0.027), whereas specificity is 53.3% (n = 8) (p = 0.027). The positive predictive value is 63.2% (n = 12), negative predictive value is 80% (n = 8), false-negative value is 20% (n = 2) and false-positive value is 36.8% (n = 7). Based on artificial intelligence decision, one cancer would have been missed.

Conclusion: Artificial intelligence can improve specificity without significantly compromising sensitivity. There was a suggested reduction in the fine needle aspiration rate, in the histologically proven benign nodules, by 53%. This had no statistical significance, likely due to the small population, however, it is thought to be the largest study to date. Further investigation with wider-ranging studies is suggested.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound
Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.70
自引率
0.00%
发文量
55
期刊介绍: Ultrasound is the official journal of the British Medical Ultrasound Society (BMUS), a multidisciplinary, charitable society comprising radiologists, obstetricians, sonographers, physicists and veterinarians amongst others.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信