Clinical Comparison of Decentration and Tilt Effects in Iris-Claw and Trans-scleral Plug Lenses: Wavefront Analysis With a Pyramidal Sensor Aberrometer.

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Lorenzo de Angelis, Vito Romano, Giuseppe Ruben Barbera, Mario Galasso, Jorge L Aliò, Fabrizio Giansanti, Francesco Barca
{"title":"Clinical Comparison of Decentration and Tilt Effects in Iris-Claw and Trans-scleral Plug Lenses: Wavefront Analysis With a Pyramidal Sensor Aberrometer.","authors":"Lorenzo de Angelis, Vito Romano, Giuseppe Ruben Barbera, Mario Galasso, Jorge L Aliò, Fabrizio Giansanti, Francesco Barca","doi":"10.3928/1081597X-20241009-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the aberrometric profile of the Artisan Aphakia lens (Opthec BV) and transscleral plug FIL-SSF lens (Soleko) and to assess the impact of tilt and decentration on their optical performance.</p><p><strong>Methods: </strong>This retrospective observational study was conducted at Azienda Ospedaliera Universitaria Careggi, Florence, Italy, with a consecutive cohort of aphakic eyes undergoing secondary lens implantation with an Artisan or FIL-SSF lens. Wavefront analysis was performed using a pyramidal wavefront-based aberrometer (Osiris-T; CSO). Tilt and decentration were calculated using anterior segment optical coherence tomography (MS-39; CSO).</p><p><strong>Results: </strong>The study included 47 eyes from 45 patients: 24 eyes in the FIL-SSF group and 23 eyes in the Artisan group. Decentration was 0.39 ± 0.14 mm in the FIL-SSF group and 0.51 ± 0.16 mm in the Artisan group (<i>P</i> = .02). The mean tilt value was 6.6 ± 2.35 degrees in the FIL-SSF group and 5.9 ± 1.86 degrees in the Artisan group (<i>P</i> = .13). Internal higher order aberrations (HOAs) were 0.23 ± 0.07 μm in the FIL-SSF group and 0.29 ± 0.13 μm in the Artisan group (<i>P</i> = .02). The point spread function (PSF) Strehl ratio was 0.12 ± 0.05 in the FIL-SSF group and 0.10 ± 0.04 (<i>P</i> = .11) in the Artisan group. The PSF Strehl ratio without lower order aberration (PSFw2) was 0.28 ± 0.12 in the FIL-SSF group and 0.23 ± 0.09 in the Artisan group (<i>P</i> = .01).</p><p><strong>Conclusions: </strong>The Artisan and FIL-SSF lenses provide comparable optical performance in terms of the PSF Strehl ratio. However, the Artisan lens appears to be more susceptible to decentration, which may result in increased higher order aberrations and a consequently lower PSFw2 Strehl ratio. <b>[<i>J Refract Surg</i>. 2024;40(12):e926-e933.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 12","pages":"e926-e933"},"PeriodicalIF":2.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20241009-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the aberrometric profile of the Artisan Aphakia lens (Opthec BV) and transscleral plug FIL-SSF lens (Soleko) and to assess the impact of tilt and decentration on their optical performance.

Methods: This retrospective observational study was conducted at Azienda Ospedaliera Universitaria Careggi, Florence, Italy, with a consecutive cohort of aphakic eyes undergoing secondary lens implantation with an Artisan or FIL-SSF lens. Wavefront analysis was performed using a pyramidal wavefront-based aberrometer (Osiris-T; CSO). Tilt and decentration were calculated using anterior segment optical coherence tomography (MS-39; CSO).

Results: The study included 47 eyes from 45 patients: 24 eyes in the FIL-SSF group and 23 eyes in the Artisan group. Decentration was 0.39 ± 0.14 mm in the FIL-SSF group and 0.51 ± 0.16 mm in the Artisan group (P = .02). The mean tilt value was 6.6 ± 2.35 degrees in the FIL-SSF group and 5.9 ± 1.86 degrees in the Artisan group (P = .13). Internal higher order aberrations (HOAs) were 0.23 ± 0.07 μm in the FIL-SSF group and 0.29 ± 0.13 μm in the Artisan group (P = .02). The point spread function (PSF) Strehl ratio was 0.12 ± 0.05 in the FIL-SSF group and 0.10 ± 0.04 (P = .11) in the Artisan group. The PSF Strehl ratio without lower order aberration (PSFw2) was 0.28 ± 0.12 in the FIL-SSF group and 0.23 ± 0.09 in the Artisan group (P = .01).

Conclusions: The Artisan and FIL-SSF lenses provide comparable optical performance in terms of the PSF Strehl ratio. However, the Artisan lens appears to be more susceptible to decentration, which may result in increased higher order aberrations and a consequently lower PSFw2 Strehl ratio. [J Refract Surg. 2024;40(12):e926-e933.].

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信