Experimental quantification of the vibrant soundbridge stapes head (SH-) coupler in human cadaveric temporal bones.

IF 1.8 3区 医学 Q2 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Lukas Graf, Jonas Lochner, Hamidreza Mojallal, Andreas Arnold, Flurin Honegger, Christof Stieger
{"title":"Experimental quantification of the vibrant soundbridge stapes head (SH-) coupler in human cadaveric temporal bones.","authors":"Lukas Graf, Jonas Lochner, Hamidreza Mojallal, Andreas Arnold, Flurin Honegger, Christof Stieger","doi":"10.1080/14992027.2024.2434905","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The \"floating mass transducer\" (FMT) of the Vibrant Soundbridge was initially attached to the long process of the incus (LP). In patients missing an incus, coupling to the stapes head using the Vibroplasty CliP-coupler is used. Its main limitation is the height, leading to potential contact with the tympanic membrane. The new stapes head (SH)-coupler reduces the functional height but tilts the stimulation angle by 30°. We investigated the SH-coupler's magnitude and sound transmission quality compared to the LP-coupler.</p><p><strong>Methods: </strong>Laser Doppler vibrometry was used on 10 cadaveric human temporal bones. Measurements of the stapes and round window motion were taken for electrical (FMT-) stimulation during application of both couplers.</p><p><strong>Results: </strong>At the round window, the SH-coupler showed a significantly higher gain magnitude than the LP-coupler (+ 13.4 dB over 1023-3577Hz). At low frequencies (382-500Hz), the SH-coupler gain was significantly lower (-9.9 dB). Total harmonic distortions >10% at 100 dB HLeq were recorded in 3.4% of the SH- and 7.4% of the LP-couplers above 500 Hz.</p><p><strong>Conclusion: </strong>The SH-coupler's performance exceeds the LP-coupler in middle and high frequencies and is comparable to and a good alternative to the CliP-coupler, dependent on the individual anatomy.</p>","PeriodicalId":13759,"journal":{"name":"International Journal of Audiology","volume":" ","pages":"1-7"},"PeriodicalIF":1.8000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Audiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14992027.2024.2434905","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The "floating mass transducer" (FMT) of the Vibrant Soundbridge was initially attached to the long process of the incus (LP). In patients missing an incus, coupling to the stapes head using the Vibroplasty CliP-coupler is used. Its main limitation is the height, leading to potential contact with the tympanic membrane. The new stapes head (SH)-coupler reduces the functional height but tilts the stimulation angle by 30°. We investigated the SH-coupler's magnitude and sound transmission quality compared to the LP-coupler.

Methods: Laser Doppler vibrometry was used on 10 cadaveric human temporal bones. Measurements of the stapes and round window motion were taken for electrical (FMT-) stimulation during application of both couplers.

Results: At the round window, the SH-coupler showed a significantly higher gain magnitude than the LP-coupler (+ 13.4 dB over 1023-3577Hz). At low frequencies (382-500Hz), the SH-coupler gain was significantly lower (-9.9 dB). Total harmonic distortions >10% at 100 dB HLeq were recorded in 3.4% of the SH- and 7.4% of the LP-couplers above 500 Hz.

Conclusion: The SH-coupler's performance exceeds the LP-coupler in middle and high frequencies and is comparable to and a good alternative to the CliP-coupler, dependent on the individual anatomy.

求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Audiology
International Journal of Audiology 医学-耳鼻喉科学
CiteScore
4.90
自引率
14.80%
发文量
133
审稿时长
4-8 weeks
期刊介绍: International Journal of Audiology is committed to furthering development of a scientifically robust evidence base for audiology. The journal is published by the British Society of Audiology, the International Society of Audiology and the Nordic Audiological Society.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信