Effectiveness of intrabronchial local anesthesia with a spray catheter and continuous oral suction in reducing cough during bronchoscopy: A prospective study

IF 2.4 Q2 RESPIRATORY SYSTEM
Kazuo Tsuchiya, Tomotsugu Nuki, Tomo Tsunoda, Taisuke Ito, Rie Mori, Takuro Akashi, Yoshiyuki Oyama, Masaki Ikeda
{"title":"Effectiveness of intrabronchial local anesthesia with a spray catheter and continuous oral suction in reducing cough during bronchoscopy: A prospective study","authors":"Kazuo Tsuchiya,&nbsp;Tomotsugu Nuki,&nbsp;Tomo Tsunoda,&nbsp;Taisuke Ito,&nbsp;Rie Mori,&nbsp;Takuro Akashi,&nbsp;Yoshiyuki Oyama,&nbsp;Masaki Ikeda","doi":"10.1016/j.resinv.2024.12.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Coughing and other distress during bronchoscopy are undesirable for both patients and bronchoscopists. The efficacy of local anesthetics administered via aerosol sprays in the airways has been documented; however, the optimal administration method remains unclear. Furthermore, the efficacy of continuous salivary aspiration in reducing cough and other distress has not yet been evaluated.</div></div><div><h3>Methods</h3><div>Patients scheduled for bronchoscopy were assigned to 1 of 4 groups—group A (intrabronchial local anesthesia using a syringe without continuous oral suction); group B (intrabronchial local anesthesia using a spray catheter without continuous oral suction); group C (intrabronchial local anesthesia using a syringe with continuous oral suction using a saliva ejector); group D (intrabronchial local anesthesia using a spray catheter with continuous oral suction using a saliva ejector). The distress levels of the patients were evaluated using a questionnaire with a visual analog scale, and cough counts were quantified during bronchoscopy. Additionally, we assessed the total amount of lidocaine consumed and changes in vital signs.</div></div><div><h3>Results</h3><div>Local anesthesia in the airway using a spray catheter did not reduce patient distress; however, it reduced cough frequency (<em>P</em> = 0.03) and lidocaine dosage (<em>P</em> = 0.0004). Continuous suctioning of saliva did not reduce the patients’ distress or cough frequency.</div></div><div><h3>Conclusion</h3><div>The use of a spray catheter rather than a syringe is recommended for administering local anesthesia with lidocaine during bronchoscopy. Conversely, continuous suctioning of saliva is not routinely recommended for all patients.</div></div>","PeriodicalId":20934,"journal":{"name":"Respiratory investigation","volume":"63 1","pages":"Pages 67-73"},"PeriodicalIF":2.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiratory investigation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212534524001898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Coughing and other distress during bronchoscopy are undesirable for both patients and bronchoscopists. The efficacy of local anesthetics administered via aerosol sprays in the airways has been documented; however, the optimal administration method remains unclear. Furthermore, the efficacy of continuous salivary aspiration in reducing cough and other distress has not yet been evaluated.

Methods

Patients scheduled for bronchoscopy were assigned to 1 of 4 groups—group A (intrabronchial local anesthesia using a syringe without continuous oral suction); group B (intrabronchial local anesthesia using a spray catheter without continuous oral suction); group C (intrabronchial local anesthesia using a syringe with continuous oral suction using a saliva ejector); group D (intrabronchial local anesthesia using a spray catheter with continuous oral suction using a saliva ejector). The distress levels of the patients were evaluated using a questionnaire with a visual analog scale, and cough counts were quantified during bronchoscopy. Additionally, we assessed the total amount of lidocaine consumed and changes in vital signs.

Results

Local anesthesia in the airway using a spray catheter did not reduce patient distress; however, it reduced cough frequency (P = 0.03) and lidocaine dosage (P = 0.0004). Continuous suctioning of saliva did not reduce the patients’ distress or cough frequency.

Conclusion

The use of a spray catheter rather than a syringe is recommended for administering local anesthesia with lidocaine during bronchoscopy. Conversely, continuous suctioning of saliva is not routinely recommended for all patients.
支气管局部麻醉雾化导管和持续口腔吸痰在支气管镜检查中减少咳嗽的有效性:一项前瞻性研究。
背景:支气管镜检查时咳嗽和其他不适对患者和支气管镜医师都是不可取的。局部麻醉药通过气雾喷雾在气道中施用的有效性已被记录;然而,最佳给药方法尚不清楚。此外,持续唾液吸吸在减少咳嗽和其他痛苦方面的疗效尚未得到评估。方法:将拟行支气管镜检查的患者分为1组,共4组:A组(支气管局部麻醉,使用注射器,不进行连续口腔吸痰);B组(支气管局部麻醉,使用喷雾导管,不持续口腔吸痰);C组(支气管局部麻醉,使用注射器持续口腔吸痰);D组(支气管局部麻醉,使用喷雾导管,使用唾液喷射器持续口腔吸引)。采用带有视觉模拟量表的问卷评估患者的痛苦程度,并对支气管镜检查期间的咳嗽计数进行量化。此外,我们评估了利多卡因消耗总量和生命体征的变化。结果:气道局部麻醉使用喷雾导管不能减轻患者的痛苦;而咳嗽频次(P = 0.03)和利多卡因用量(P = 0.0004)明显降低。持续吸痰并不能减轻患者的痛苦和咳嗽频率。结论:在支气管镜检查过程中,利多卡因局部麻醉推荐使用喷雾导管而不是注射器。相反,并非所有患者都常规推荐持续吸痰。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Respiratory investigation
Respiratory investigation RESPIRATORY SYSTEM-
CiteScore
4.90
自引率
6.50%
发文量
114
审稿时长
64 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信