In Vivo Acquisition of Human Retinal Double-Pass Images during Simulated Intraocular Lens Implantation.

IF 0.8 4区 医学 Q4 OPHTHALMOLOGY
Klinische Monatsblatter fur Augenheilkunde Pub Date : 2024-12-01 Epub Date: 2024-12-05 DOI:10.1055/a-2453-8253
Karsten Sperlich, Sebastian Bohn, Mario Gerlach, Julia Schubert, Heinrich Stolz, Rudolf Guthoff, Oliver Stachs
{"title":"In Vivo Acquisition of Human Retinal Double-Pass Images during Simulated Intraocular Lens Implantation.","authors":"Karsten Sperlich, Sebastian Bohn, Mario Gerlach, Julia Schubert, Heinrich Stolz, Rudolf Guthoff, Oliver Stachs","doi":"10.1055/a-2453-8253","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of the study was to capture images that form on the human retina after the simulated implantation of an intraocular lens (IOL). White light was used rather than the commonly used near-infrared light, which is unsuitable for the examination of diffractive IOLs. For this purpose, a special optical setup was developed to investigate the influence of the IOL design on two-dimensional retinal images <i>in vivo</i>.</p><p><strong>Materials and methods: </strong>A double-pass ophthalmoscopic setup with a scientific CCD camera system was developed. Imaging the retinal image of a white LED located at infinity provides access to the double-pass point spread function of the natural eye. Subsequently, a see-through device for simulated IOL implantation (VirtIOL, 10Lens S. L. U., Terrassa, Spain) was integrated to investigate the influence of the IOL design on the retinal image quality of complex scenarios.</p><p><strong>Results: </strong>Retinal images were acquired from an incoherent white point light source. Combined with simulated IOL implantation, retinal images were acquired from the point light source, letters, and a United States Airforce target on a 6-m distant monitor. As expected, the double-pass images obtained with a monofocal IOL were sharper than those obtained with a multifocal IOL.</p><p><strong>Conclusion: </strong>The method opens up access to double-pass point spread function for white light, thus solving the problem of infrared light-based methods providing incorrect results when examining diffractive IOLs. This approach may be helpful for the investigation of perception in the future.</p>","PeriodicalId":17904,"journal":{"name":"Klinische Monatsblatter fur Augenheilkunde","volume":"241 12","pages":"1302-1308"},"PeriodicalIF":0.8000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Klinische Monatsblatter fur Augenheilkunde","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2453-8253","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The aim of the study was to capture images that form on the human retina after the simulated implantation of an intraocular lens (IOL). White light was used rather than the commonly used near-infrared light, which is unsuitable for the examination of diffractive IOLs. For this purpose, a special optical setup was developed to investigate the influence of the IOL design on two-dimensional retinal images in vivo.

Materials and methods: A double-pass ophthalmoscopic setup with a scientific CCD camera system was developed. Imaging the retinal image of a white LED located at infinity provides access to the double-pass point spread function of the natural eye. Subsequently, a see-through device for simulated IOL implantation (VirtIOL, 10Lens S. L. U., Terrassa, Spain) was integrated to investigate the influence of the IOL design on the retinal image quality of complex scenarios.

Results: Retinal images were acquired from an incoherent white point light source. Combined with simulated IOL implantation, retinal images were acquired from the point light source, letters, and a United States Airforce target on a 6-m distant monitor. As expected, the double-pass images obtained with a monofocal IOL were sharper than those obtained with a multifocal IOL.

Conclusion: The method opens up access to double-pass point spread function for white light, thus solving the problem of infrared light-based methods providing incorrect results when examining diffractive IOLs. This approach may be helpful for the investigation of perception in the future.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
235
审稿时长
4-8 weeks
期刊介绍: -Konzentriertes Fachwissen aus Klinik und Praxis: Die entscheidenden Ergebnisse der internationalen Forschung - für Sie auf den Punkt gebracht und kritisch kommentiert, Übersichtsarbeiten zu den maßgeblichen Themen der täglichen Praxis, Top informiert - breite klinische Berichterstattung. -CME-Punkte sammeln mit dem Refresher: Effiziente, CME-zertifizierte Fortbildung, mit dem Refresher, 3 CME-Punkte pro Ausgabe - bis zu 36 CME-Punkte im Jahr!. -Aktuelle Rubriken mit echtem Nutzwert: Kurzreferate zu den wichtigsten Artikeln internationaler Zeitschriften, Schwerpunktthema in jedem Heft: Ausführliche Übersichtsarbeiten zu den wichtigsten Themen der Ophthalmologie – so behalten Sie das gesamte Fach im Blick!, Originalien mit den neuesten Entwicklungen, Übersichten zu den relevanten Themen.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信