Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation-Initial validation in relation to invasive blood sampling.

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Jiahao Li, Pablo Villar-Calle, Caitlin Chiu, Mahniz Reza, Nupoor Narula, Chao Li, Jinwei Zhang, Thanh D Nguyen, Yi Wang, Robert S Zhang, Jiwon Kim, Jonathan W Weinsaft, Pascal Spincemaille
{"title":"Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation-Initial validation in relation to invasive blood sampling.","authors":"Jiahao Li, Pablo Villar-Calle, Caitlin Chiu, Mahniz Reza, Nupoor Narula, Chao Li, Jinwei Zhang, Thanh D Nguyen, Yi Wang, Robert S Zhang, Jiwon Kim, Jonathan W Weinsaft, Pascal Spincemaille","doi":"10.1002/mrm.30393","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop a breath-hold cardiac quantitative susceptibility mapping (QSM) sequence for noninvasive measurement of differential cardiac chamber blood oxygen saturation (ΔSO<sub>2</sub>).</p><p><strong>Methods: </strong>A non-gated three-dimensional stack-of-spirals QSM sequence was implemented to continuously sample the data throughout the cardiac cycle. Measurements of ΔSO<sub>2</sub> between the right and left heart chamber obtained by the proposed sequence and a previously validated navigator Cartesian QSM sequence were compared in three cohorts consisting of healthy volunteers, coronavirus disease 2019 survivors, and patients with pulmonary hypertension. In the pulmonary-hypertension cohort, Bland-Altman plots were used to assess the agreement of ΔSO<sub>2</sub> values obtained by QSM and those obtained by invasive right heart catheterization (RHC).</p><p><strong>Results: </strong>Compared with navigator QSM (average acquisition time 419 ± 158 s), spiral QSM reduced the scan time on average by over 20-fold to a 20-s breath-hold. In all three cohorts, spiral QSM and navigator QSM yielded similar ΔSO<sub>2</sub>. Among healthy volunteers and coronavirus disease 2019 survivors, ΔSO<sub>2</sub> was 17.41 ± 4.35% versus 17.67 ± 4.09% for spiral and navigator QSM, respectively. In pulmonary-hypertension patients, spiral QSM showed a slightly smaller ΔSO<sub>2</sub> bias and narrower 95% limits of agreement than that obtained by navigator QSM (1.09% ± 6.47% vs. 2.79% ± 6.99%) when compared with right heart catheterization.</p><p><strong>Conclusion: </strong>Breath-hold three-dimensional spiral cardiac QSM for measuring differential cardiac chamber blood oxygenation is feasible and provides values in good agreement with navigator cardiac QSM and with reference right heart catheterization.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30393","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To develop a breath-hold cardiac quantitative susceptibility mapping (QSM) sequence for noninvasive measurement of differential cardiac chamber blood oxygen saturation (ΔSO2).

Methods: A non-gated three-dimensional stack-of-spirals QSM sequence was implemented to continuously sample the data throughout the cardiac cycle. Measurements of ΔSO2 between the right and left heart chamber obtained by the proposed sequence and a previously validated navigator Cartesian QSM sequence were compared in three cohorts consisting of healthy volunteers, coronavirus disease 2019 survivors, and patients with pulmonary hypertension. In the pulmonary-hypertension cohort, Bland-Altman plots were used to assess the agreement of ΔSO2 values obtained by QSM and those obtained by invasive right heart catheterization (RHC).

Results: Compared with navigator QSM (average acquisition time 419 ± 158 s), spiral QSM reduced the scan time on average by over 20-fold to a 20-s breath-hold. In all three cohorts, spiral QSM and navigator QSM yielded similar ΔSO2. Among healthy volunteers and coronavirus disease 2019 survivors, ΔSO2 was 17.41 ± 4.35% versus 17.67 ± 4.09% for spiral and navigator QSM, respectively. In pulmonary-hypertension patients, spiral QSM showed a slightly smaller ΔSO2 bias and narrower 95% limits of agreement than that obtained by navigator QSM (1.09% ± 6.47% vs. 2.79% ± 6.99%) when compared with right heart catheterization.

Conclusion: Breath-hold three-dimensional spiral cardiac QSM for measuring differential cardiac chamber blood oxygenation is feasible and provides values in good agreement with navigator cardiac QSM and with reference right heart catheterization.

不同心腔氧合的螺旋心脏定量敏感性制图-与侵入性血液取样相关的初步验证。
目的:开发一种憋气心脏定量易感性图谱(QSM)序列,用于无创测量差分心室血氧饱和度(ΔSO2)。方法:采用非门控的三维叠螺旋QSM序列,在整个心脏周期内连续采样数据。在由健康志愿者、2019冠状病毒病幸存者和肺动脉高压患者组成的三个队列中,比较了由拟议序列和先前验证的导航笛卡尔QSM序列获得的左右心室之间ΔSO2的测量值。在肺动脉高压队列中,Bland-Altman图用于评估QSM获得的ΔSO2值与有创右心导管(RHC)获得的值的一致性。结果:与导航仪QSM(平均采集时间419±158 s)相比,螺旋QSM的扫描时间平均缩短20倍以上,屏气时间为20 s。在所有三个队列中,螺旋QSM和导航QSM的结果相似ΔSO2。在健康志愿者和2019冠状病毒病幸存者中,螺旋QSM和导航QSM的ΔSO2分别为17.41±4.35%和17.67±4.09%。在肺动脉高压患者中,螺旋QSM与导航QSM相比(1.09%±6.47% vs. 2.79%±6.99%)的偏差ΔSO2略小,95%的一致性限窄。结论:屏气三维螺旋心脏QSM测量心室血氧差异是可行的,与导航仪心脏QSM及参考右心导管测量值吻合良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信