{"title":"Compact multiplex PCR device for HIV-1 and HIV-2 viral load determination from finger-prick whole blood in resource-limited settings.","authors":"Tianyi Liu, Anthony J Politza, Md Ahasan Ahamed, Aneesh Kshirsagar, Yusheng Zhu, Weihua Guan","doi":"10.1016/j.bios.2024.116997","DOIUrl":null,"url":null,"abstract":"<p><p>The human immunodeficiency virus (HIV) remains a major global health concern for which accurate viral load monitoring is essential for the management of HIV infection. The advent of antiretroviral therapy (ART) has transformed once-fatal HIV disease into a manageable chronic condition that now makes the need for VL testing which aims to satisfy international suppression targets 95-95-95 al l the more essential. Therefore, considering the complexity and diversity of HIV infection, it is essential to develop rapid diagnostic technologies suitable for different clinical situations. Here, we report on a multiplexed PCR device developed for simple and efficient quantification of HIV-1 or HIV-2 viral loads using finger-pricked whole blood from rural decentralized settings. This device is comprised of a previously developed RNA extraction module combined with an optimized real-time PCR amplification system. Together, these combine to simultaneously detect and differentiate HIV-1 & 2; as well are adopting a testing control of RNase P allowing for full diagnostic analysis from one sample. Our device also includes an intuitive user interface and is completely autonomous so it can serve individuals in remote areas who are unfamiliar with the field of medical testing. They get the results in a very short time of around 70 min and hence save on testing times without leaving accuracy behind. The efficiency and effectiveness of the device were validated through the analysis of 30 clinical samples, yielding a sensitivity of 100% for both HIV-1 and HIV-2. The specificity was found to be 100% for HIV-1 and 90.91% for HIV-2, demonstrating high diagnostic accuracy. One of the most attractive things about this device is that it comes in comparison to all other counterparts. Given that you can run the assay for less than $10, it could be an economically viable way to use this as a broadscale test in regions where healthcare budgets don't allow others. Hence it is quite a useful device to aid HIV management in resource-limited settings, where conventional laboratory facilities are out of reach due its simplicity and affordability with rapid output. The point-of-care test is an effective, low-cost, high quality diagnostic tool-promoting rapid testing for HIV-inexpensively overcoming the barriers to efficient control of and care in resource-limited settings.</p>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"271 ","pages":"116997"},"PeriodicalIF":10.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://doi.org/10.1016/j.bios.2024.116997","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
The human immunodeficiency virus (HIV) remains a major global health concern for which accurate viral load monitoring is essential for the management of HIV infection. The advent of antiretroviral therapy (ART) has transformed once-fatal HIV disease into a manageable chronic condition that now makes the need for VL testing which aims to satisfy international suppression targets 95-95-95 al l the more essential. Therefore, considering the complexity and diversity of HIV infection, it is essential to develop rapid diagnostic technologies suitable for different clinical situations. Here, we report on a multiplexed PCR device developed for simple and efficient quantification of HIV-1 or HIV-2 viral loads using finger-pricked whole blood from rural decentralized settings. This device is comprised of a previously developed RNA extraction module combined with an optimized real-time PCR amplification system. Together, these combine to simultaneously detect and differentiate HIV-1 & 2; as well are adopting a testing control of RNase P allowing for full diagnostic analysis from one sample. Our device also includes an intuitive user interface and is completely autonomous so it can serve individuals in remote areas who are unfamiliar with the field of medical testing. They get the results in a very short time of around 70 min and hence save on testing times without leaving accuracy behind. The efficiency and effectiveness of the device were validated through the analysis of 30 clinical samples, yielding a sensitivity of 100% for both HIV-1 and HIV-2. The specificity was found to be 100% for HIV-1 and 90.91% for HIV-2, demonstrating high diagnostic accuracy. One of the most attractive things about this device is that it comes in comparison to all other counterparts. Given that you can run the assay for less than $10, it could be an economically viable way to use this as a broadscale test in regions where healthcare budgets don't allow others. Hence it is quite a useful device to aid HIV management in resource-limited settings, where conventional laboratory facilities are out of reach due its simplicity and affordability with rapid output. The point-of-care test is an effective, low-cost, high quality diagnostic tool-promoting rapid testing for HIV-inexpensively overcoming the barriers to efficient control of and care in resource-limited settings.
期刊介绍:
Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.