{"title":"Assessment of mumps virus-specific antibodies: Comparison of three different enzyme immunoassays and neutralization test.","authors":"Yuka Mihara, Tetsuo Nakayama, Fumihiko Hattori, Midori Yamada, Tetsushi Yoshikawa","doi":"10.1016/j.jiac.2024.11.021","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>We evaluated the application of a newly improved enzyme immunoassay (EIA) kit, Mumps IgG Seiken®, by comparing antibody responses to different EIA kits, and neutralization tests (NTs), using clinical samples.</p><p><strong>Methods: </strong>Serum samples were collected before and 4-6 weeks after vaccination from 128 children who had no history of mumps or mumps vaccination. Using three different EIA kits, Mumps IgG Seiken®, a commercial kit from Enzygnost®, and an in-house kit, mumps-specific IgG antibodies were measured. Anti-mumps antibody responses between each of the EIA kits and NTs were evaluated.</p><p><strong>Results: </strong>Before vaccination, all samples were seronegative, except for three serum samples measured by Mumps IgG Seiken®, which exhibited equivocal. The antibody-positivity rates and equivocal rates of Mumps IgG Seiken® post-vaccination (71.1 % and 23.4 %, respectively) were comparable to those of Enzygnost® (74.2 % and 19.5 %, respectively). However, antibody-positivity and equivocal rates were significantly higher and lower than those of in-house kit (51.6 % and 40.6 %, respectively) (p < 0.05). The concordance rates of the kit (68.7 %) were comparable to those of Enzygnost® (71.1 %) and higher than those of in-house-developed kit (58.6 %) (p < 0.05). The area under curve of the three EIA kits were 0.801, 0.804, and 0.859; however, the differences did not reach significance. Correlations of the values obtained using three EIA kits with NTs were 0.71, 0.61, and 0.78.</p><p><strong>Conclusion: </strong>The newly approved Mumps IgG Seiken® showed good correlation with NTs and had lower equivocal rates compared to in-house kit, comparable to Enzygnost®. This kit may be clinically acceptable for the evaluation of vaccine immunogenicity.</p>","PeriodicalId":16103,"journal":{"name":"Journal of Infection and Chemotherapy","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Infection and Chemotherapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jiac.2024.11.021","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: We evaluated the application of a newly improved enzyme immunoassay (EIA) kit, Mumps IgG Seiken®, by comparing antibody responses to different EIA kits, and neutralization tests (NTs), using clinical samples.
Methods: Serum samples were collected before and 4-6 weeks after vaccination from 128 children who had no history of mumps or mumps vaccination. Using three different EIA kits, Mumps IgG Seiken®, a commercial kit from Enzygnost®, and an in-house kit, mumps-specific IgG antibodies were measured. Anti-mumps antibody responses between each of the EIA kits and NTs were evaluated.
Results: Before vaccination, all samples were seronegative, except for three serum samples measured by Mumps IgG Seiken®, which exhibited equivocal. The antibody-positivity rates and equivocal rates of Mumps IgG Seiken® post-vaccination (71.1 % and 23.4 %, respectively) were comparable to those of Enzygnost® (74.2 % and 19.5 %, respectively). However, antibody-positivity and equivocal rates were significantly higher and lower than those of in-house kit (51.6 % and 40.6 %, respectively) (p < 0.05). The concordance rates of the kit (68.7 %) were comparable to those of Enzygnost® (71.1 %) and higher than those of in-house-developed kit (58.6 %) (p < 0.05). The area under curve of the three EIA kits were 0.801, 0.804, and 0.859; however, the differences did not reach significance. Correlations of the values obtained using three EIA kits with NTs were 0.71, 0.61, and 0.78.
Conclusion: The newly approved Mumps IgG Seiken® showed good correlation with NTs and had lower equivocal rates compared to in-house kit, comparable to Enzygnost®. This kit may be clinically acceptable for the evaluation of vaccine immunogenicity.
期刊介绍:
The Journal of Infection and Chemotherapy (JIC) — official journal of the Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases — welcomes original papers, laboratory or clinical, as well as case reports, notes, committee reports, surveillance and guidelines from all parts of the world on all aspects of chemotherapy, covering the pathogenesis, diagnosis, treatment, and control of infection, including treatment with anticancer drugs. Experimental studies on animal models and pharmacokinetics, and reports on epidemiology and clinical trials are particularly welcome.