{"title":"Radiographic Changes and Clinical Outcomes Associated with Two Different Press-Fit Humeral Stems in Primary Reverse Shoulder Arthroplasty.","authors":"M F Catma, İ F Adıgüzel, S Y Yildiz","doi":"10.4103/njcp.njcp_179_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Reverse shoulder arthroplasty (RSA) is used commonly for a wide range of indications. The complications after the total shoulder replacements have been reported to be related with the prosthesis design. The type of the humeral stem is a consideration to reduce complication. Radiographic changes are seen at a high rate with new-generation press-fit stems.</p><p><strong>Aim: </strong>This study aims to reduce proximal humeral bone loss after RSA could have been achieved with adjustable humeral stem when compared with monoblock stem.</p><p><strong>Methods: </strong>A retrospective analysis was made of 52 patients treated with RSA using a press-fit humeral stem prosthesis. The patients were separated into two groups according to the type of humeral stem. The first group included 26 patients (18 females, 8 males) who underwent RSA using adjustable humeral stem. The second group included of 26 patients (17 females, 9 males) for whom monoblock humeral stem was used. Clinical and radiological evaluations were made based on the information obtained at 1, 3, 6, 12, and 18 months postoperatively. The follow-up duration was at least 18 months.</p><p><strong>Results: </strong>There was no statistical difference between the adjustable and monoblock groups in respect to gender, age, height, and weight. According to the functional measurements at the final follow-up, no statistically significant difference was determined between the groups with respect to the Constant, UCLA, Oxford, DASH, and VAS values. In terms of radiographic changes, both groups were seen to have been similarly affected. It was found that, irrespective of the stem type used, the humeral side radiographic adaptation was found to be high, which negatively affected the functional results (P < 0.05).</p><p><strong>Conclusion: </strong>The increased radiographic stress shielding adaptation leading to humeral osteolysis was found to have a negative effect on the functional results with the press-fit technique irrespective of stem design.</p>","PeriodicalId":19431,"journal":{"name":"Nigerian Journal of Clinical Practice","volume":"27 11","pages":"1252-1259"},"PeriodicalIF":0.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nigerian Journal of Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/njcp.njcp_179_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Reverse shoulder arthroplasty (RSA) is used commonly for a wide range of indications. The complications after the total shoulder replacements have been reported to be related with the prosthesis design. The type of the humeral stem is a consideration to reduce complication. Radiographic changes are seen at a high rate with new-generation press-fit stems.

Aim: This study aims to reduce proximal humeral bone loss after RSA could have been achieved with adjustable humeral stem when compared with monoblock stem.

Methods: A retrospective analysis was made of 52 patients treated with RSA using a press-fit humeral stem prosthesis. The patients were separated into two groups according to the type of humeral stem. The first group included 26 patients (18 females, 8 males) who underwent RSA using adjustable humeral stem. The second group included of 26 patients (17 females, 9 males) for whom monoblock humeral stem was used. Clinical and radiological evaluations were made based on the information obtained at 1, 3, 6, 12, and 18 months postoperatively. The follow-up duration was at least 18 months.

Results: There was no statistical difference between the adjustable and monoblock groups in respect to gender, age, height, and weight. According to the functional measurements at the final follow-up, no statistically significant difference was determined between the groups with respect to the Constant, UCLA, Oxford, DASH, and VAS values. In terms of radiographic changes, both groups were seen to have been similarly affected. It was found that, irrespective of the stem type used, the humeral side radiographic adaptation was found to be high, which negatively affected the functional results (P < 0.05).

Conclusion: The increased radiographic stress shielding adaptation leading to humeral osteolysis was found to have a negative effect on the functional results with the press-fit technique irrespective of stem design.

初次肩关节置换术中两种不同肱骨柄压合的影像学改变和临床结果。
背景:反向肩关节置换术(RSA)通常用于广泛的适应症。据报道,全肩关节置换术后的并发症与假体设计有关。肱骨干的类型是减少并发症的一个考虑因素。新一代压合式导管的x线片改变率很高。目的:本研究旨在减少肱骨近端骨丢失,与单块肱骨干相比,可调节肱骨干可以实现RSA术后肱骨近端骨丢失。方法:回顾性分析52例采用加压式肱骨干假体治疗RSA的患者。根据肱骨干类型将患者分为两组。第一组包括26名患者(18名女性,8名男性),他们使用可调节的肱骨干进行RSA。第二组包括26例患者(17例女性,9例男性),采用单块肱骨干。根据术后1、3、6、12和18个月获得的信息进行临床和放射学评估。随访时间至少18个月。结果:可调节组与单块组在性别、年龄、身高、体重方面无统计学差异。根据最终随访时的功能测量,各组之间在Constant、UCLA、Oxford、DASH和VAS值方面无统计学差异。在影像学改变方面,两组患者的影响相似。我们发现,无论使用何种柄型,肱骨侧的x线适应度都很高,这对功能结果有负面影响(P < 0.05)。结论:无论椎体设计如何,增加的放射学应力屏蔽适应导致肱骨溶解对加压配合技术的功能结果有负面影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Nigerian Journal of Clinical Practice
Nigerian Journal of Clinical Practice MEDICINE, GENERAL & INTERNAL-
CiteScore
1.40
自引率
0.00%
发文量
275
审稿时长
4-8 weeks
期刊介绍: The Nigerian Journal of Clinical Practice is a Monthly peer-reviewed international journal published by the Medical and Dental Consultants’ Association of Nigeria. The journal’s full text is available online at www.njcponline.com. The journal allows free access (Open Access) to its contents and permits authors to self-archive final accepted version of the articles on any OAI-compliant institutional / subject-based repository. The journal makes a token charge for submission, processing and publication of manuscripts including color reproduction of photographs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信