A Cu/β-cyclodextrin/reduced graphene oxide nanocomposite for efficient and multi-aflatoxin detection in rice, ginger and bean samples.

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Behnaz Shahryari, Rouhollah Khani, Javad Feizy
{"title":"A Cu/β-cyclodextrin/reduced graphene oxide nanocomposite for efficient and multi-aflatoxin detection in rice, ginger and bean samples.","authors":"Behnaz Shahryari, Rouhollah Khani, Javad Feizy","doi":"10.1039/d4ay01846j","DOIUrl":null,"url":null,"abstract":"<p><p>Aflatoxins (AFs) are some of the most important mycotoxins or fungal toxins that cause contamination of food products and are considered a threat to human and animal health. An efficient Cu/β-cyclodextrin/reduced graphene oxide nanocomposite (Cu/β-CD/rGO) has been prepared and applied as a new solid-phase extraction adsorbent for the separation and preconcentration of four AFs (B<sub>1</sub>, B<sub>2</sub>, G<sub>1</sub>, and G<sub>2</sub>) using high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The successful synthesis of the prepared nanocomposite was confirmed using Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), and transmission electron microscopy (TEM). The impacts of pH, amount of adsorbent, sample volume, desorption solvent volume, and salt concentration on the recovery of AFs were precisely investigated and optimized by central composite design (CCD). Under the optimal conditions, the introduced method demonstrated good linearity in the range of 0.4-5.4, 0.08-1.08, 0.4-5.4, and 0.08-1.08 ng g<sup>-1</sup> for AFs B<sub>1</sub>, B<sub>2</sub>, G<sub>1</sub> and G<sub>2</sub>, respectively. The limits of detection and quantification for the four AFs were obtained in the range of 0.06-0.53 and 0.20-1.62 ng g<sup>-1</sup>, respectively. The accuracy of the method was evaluated using recovery measurements in spiked real samples such as rice, bean, and ginger samples, and satisfactory recoveries were obtained in the range of 83.5-109.0% with good precision (RSDs between 2.4 and 8.6%). The results of this research revealed that our developed method is sensitive, highly effective, and convenient to perform for the trace analysis of AFs in different real samples.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay01846j","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Aflatoxins (AFs) are some of the most important mycotoxins or fungal toxins that cause contamination of food products and are considered a threat to human and animal health. An efficient Cu/β-cyclodextrin/reduced graphene oxide nanocomposite (Cu/β-CD/rGO) has been prepared and applied as a new solid-phase extraction adsorbent for the separation and preconcentration of four AFs (B1, B2, G1, and G2) using high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The successful synthesis of the prepared nanocomposite was confirmed using Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), and transmission electron microscopy (TEM). The impacts of pH, amount of adsorbent, sample volume, desorption solvent volume, and salt concentration on the recovery of AFs were precisely investigated and optimized by central composite design (CCD). Under the optimal conditions, the introduced method demonstrated good linearity in the range of 0.4-5.4, 0.08-1.08, 0.4-5.4, and 0.08-1.08 ng g-1 for AFs B1, B2, G1 and G2, respectively. The limits of detection and quantification for the four AFs were obtained in the range of 0.06-0.53 and 0.20-1.62 ng g-1, respectively. The accuracy of the method was evaluated using recovery measurements in spiked real samples such as rice, bean, and ginger samples, and satisfactory recoveries were obtained in the range of 83.5-109.0% with good precision (RSDs between 2.4 and 8.6%). The results of this research revealed that our developed method is sensitive, highly effective, and convenient to perform for the trace analysis of AFs in different real samples.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信