Bacterial Cellulose/Polyelectrolyte Complex Hydrogel Separator with Thermal and Dimensional Stabilities for Dendrite Suppression in Zinc Ion Battery.

IF 3.7 3区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
ACS Omega Pub Date : 2024-11-15 eCollection Date: 2024-11-26 DOI:10.1021/acsomega.4c07403
Thichakorn Sungoradee, Kawee Srikulkit
{"title":"Bacterial Cellulose/Polyelectrolyte Complex Hydrogel Separator with Thermal and Dimensional Stabilities for Dendrite Suppression in Zinc Ion Battery.","authors":"Thichakorn Sungoradee, Kawee Srikulkit","doi":"10.1021/acsomega.4c07403","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, bacterial cellulose-polyelectrolyte complex (BC/PEC) composite hydrogels were prepared for an electrode separator. First, the poly(sodium 4-styrenesulfonate)/poly(dimethyl diallyl ammonium chloride) hydrogel was prepared using NaCl as a shielding agent and a dialysis tube to control the formation of the PEC hydrogel. BC was incorporated into the supporting skeleton. The 3D BC sponge was prepared by using an alkali swollen BC gel, followed by freeze-thaw cycles to develop the porous framework. The BC backbone was then cross-linked with glutaraldehyde (GA) under acidic conditions to obtain cross-linked BC (BC-GA), resulting in the improved dimensional stability of the BC skeleton in an alkali medium. Subsequently, the PEC was introduced into the BC-GA pores, resulting in the BC-GA/PEC composite hydrogel with improved mechanical and dimensional properties and thermal stability. Electrolyte permeability tests with 6 M KOH showed that BC/PEC had lower permeability (approximately 2 × 10<sup>-2</sup> cm<sup>2</sup>/min) compared to BC and BC-GA (1.0-1.5 × 10<sup>-1</sup> cm<sup>2</sup>/min) compared to the ionic conductivity of BC-GA/PEC with values of 30.9-55.9 mS/cm. The charge-discharge cycling performance of BC-GA/PEC hydrogels as a zinc battery separator was evaluated using plating/stripping tests, revealing that the zinc anode surface exhibited less corrosion and slower dendrite growth. This phenomenon was due to the decrease in Zn<sup>2+</sup> crossover by either repulsion or attraction forces between Zn<sup>2+</sup> and BC-GA/PEC hydrogels, making them an alternative for electrode separators in place of liquid electrolyte separators.</p>","PeriodicalId":22,"journal":{"name":"ACS Omega","volume":"9 47","pages":"47088-47096"},"PeriodicalIF":3.7000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11603217/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Omega","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acsomega.4c07403","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/26 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, bacterial cellulose-polyelectrolyte complex (BC/PEC) composite hydrogels were prepared for an electrode separator. First, the poly(sodium 4-styrenesulfonate)/poly(dimethyl diallyl ammonium chloride) hydrogel was prepared using NaCl as a shielding agent and a dialysis tube to control the formation of the PEC hydrogel. BC was incorporated into the supporting skeleton. The 3D BC sponge was prepared by using an alkali swollen BC gel, followed by freeze-thaw cycles to develop the porous framework. The BC backbone was then cross-linked with glutaraldehyde (GA) under acidic conditions to obtain cross-linked BC (BC-GA), resulting in the improved dimensional stability of the BC skeleton in an alkali medium. Subsequently, the PEC was introduced into the BC-GA pores, resulting in the BC-GA/PEC composite hydrogel with improved mechanical and dimensional properties and thermal stability. Electrolyte permeability tests with 6 M KOH showed that BC/PEC had lower permeability (approximately 2 × 10-2 cm2/min) compared to BC and BC-GA (1.0-1.5 × 10-1 cm2/min) compared to the ionic conductivity of BC-GA/PEC with values of 30.9-55.9 mS/cm. The charge-discharge cycling performance of BC-GA/PEC hydrogels as a zinc battery separator was evaluated using plating/stripping tests, revealing that the zinc anode surface exhibited less corrosion and slower dendrite growth. This phenomenon was due to the decrease in Zn2+ crossover by either repulsion or attraction forces between Zn2+ and BC-GA/PEC hydrogels, making them an alternative for electrode separators in place of liquid electrolyte separators.

求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Omega
ACS Omega Chemical Engineering-General Chemical Engineering
CiteScore
6.60
自引率
4.90%
发文量
3945
审稿时长
2.4 months
期刊介绍: ACS Omega is an open-access global publication for scientific articles that describe new findings in chemistry and interfacing areas of science, without any perceived evaluation of immediate impact.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信