Fanny-May Santy , Anthony Pernoud , Simon Barrué-Belou , François Fourchet , Hugo Bothorel , Pierre Samozino
{"title":"Reliability of isokinetic dynamometer for isometric assessment of ankle plantar flexor strength","authors":"Fanny-May Santy , Anthony Pernoud , Simon Barrué-Belou , François Fourchet , Hugo Bothorel , Pierre Samozino","doi":"10.1016/j.ptsp.2024.11.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluate isokinetic dynamometer reliability for isometric assessment of plantar flexor (PF) strength.</div></div><div><h3>Design</h3><div>Cross-sectional.</div></div><div><h3>Setting</h3><div>Testing by the same physiotherapist twice during a first session (repeatability) and once during a second session (reproducibility).</div></div><div><h3>Participants</h3><div>Twenty-two healthy subjects (44 ankles, 11 men/11 women).</div></div><div><h3>Main outcome measures</h3><div>Isometric PF peak torque, with and without body mass normalization, at 0° and +20° of plantar flexion. Measurement reliability was evaluated using intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC).</div></div><div><h3>Results</h3><div>Without normalization, measurement repeatability was excellent at 0° of plantar flexion (ICC, 0.94; SEM, 6.6%; MDC, 18.4%) compared with good repeatability at +20° (ICC, 0.85; SEM, 11.1%; MDC 30.6%). Measurement repeatability following normalization was good at 0° (ICC, 0.88; SEM, 5.2%; MDC, 14.4%) and +20° (ICC, 0.79; SEM, 10.2%; MDC, 28.1%). While reproducibility was good at 0° with normalization (ICC, 0.84; SEM, 5.9%; MDC, 16.3%) or excellent without (ICC 0.92; SEM 7.5%; MDC, 20.8%), it was moderate at +20° with normalization (ICC 0.71; SEM 11.3%; MDC, 31.3%) or good without (ICC 0.78; SEM 13.0%; MDC, 36.1%).</div></div><div><h3>Conclusion</h3><div>The reliability of PF maximal isometric strength is good/excellent at 0° of plantar flexion but moderate/good at +20°.</div></div>","PeriodicalId":49698,"journal":{"name":"Physical Therapy in Sport","volume":"71 ","pages":"Pages 36-42"},"PeriodicalIF":2.2000,"publicationDate":"2024-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical Therapy in Sport","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1466853X24001147","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
To evaluate isokinetic dynamometer reliability for isometric assessment of plantar flexor (PF) strength.
Design
Cross-sectional.
Setting
Testing by the same physiotherapist twice during a first session (repeatability) and once during a second session (reproducibility).
Isometric PF peak torque, with and without body mass normalization, at 0° and +20° of plantar flexion. Measurement reliability was evaluated using intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC).
Results
Without normalization, measurement repeatability was excellent at 0° of plantar flexion (ICC, 0.94; SEM, 6.6%; MDC, 18.4%) compared with good repeatability at +20° (ICC, 0.85; SEM, 11.1%; MDC 30.6%). Measurement repeatability following normalization was good at 0° (ICC, 0.88; SEM, 5.2%; MDC, 14.4%) and +20° (ICC, 0.79; SEM, 10.2%; MDC, 28.1%). While reproducibility was good at 0° with normalization (ICC, 0.84; SEM, 5.9%; MDC, 16.3%) or excellent without (ICC 0.92; SEM 7.5%; MDC, 20.8%), it was moderate at +20° with normalization (ICC 0.71; SEM 11.3%; MDC, 31.3%) or good without (ICC 0.78; SEM 13.0%; MDC, 36.1%).
Conclusion
The reliability of PF maximal isometric strength is good/excellent at 0° of plantar flexion but moderate/good at +20°.
期刊介绍:
Physical Therapy in Sport is an international peer-reviewed journal that provides a forum for the publication of research and clinical practice material relevant to the healthcare professions involved in sports and exercise medicine, and rehabilitation. The journal publishes material that is indispensable for day-to-day practice and continuing professional development. Physical Therapy in Sport covers topics dealing with the diagnosis, treatment, and prevention of injuries, as well as more general areas of sports and exercise medicine and related sports science.
The journal publishes original research, case studies, reviews, masterclasses, papers on clinical approaches, and book reviews, as well as occasional reports from conferences. Papers are double-blind peer-reviewed by our international advisory board and other international experts, and submissions from a broad range of disciplines are actively encouraged.