Chengxin Su , Xiaoling Liu , Ke Zhang , Bing Jiang , Jiashuai Hu , Mei Li , Lin Cheng , Hongbing Luo , Wanchen Xie , Cheng Liu , Liangqian Fan , Wei Chen , Xiaohong Zhang
{"title":"A molecularly imprinted electrochemical sensor based on in-situ polymerization for rapid and selective detection of tonalide in aqueous environment","authors":"Chengxin Su , Xiaoling Liu , Ke Zhang , Bing Jiang , Jiashuai Hu , Mei Li , Lin Cheng , Hongbing Luo , Wanchen Xie , Cheng Liu , Liangqian Fan , Wei Chen , Xiaohong Zhang","doi":"10.1016/j.ab.2024.115730","DOIUrl":null,"url":null,"abstract":"<div><div>Given the adverse effects of tonalide (AHTN) on aquatic organisms and humans, coupled with the limitations of current detection methods, which are time-consuming, require expensive equipment and complicated sample preparation procedures, there is a clear need to develop a new technique for detecting AHTN that is highly sensitive, rapid, cost-effective and efficient. In this study, a new simple electrochemical sensor for the determination of AHTN in aqueous environments was developed for the first time through the in-situ polymerization of an AHTN-imprinted polymer on the surface of a graphene (G)-modified carbon electrode (GCE). Following a series of comparative tests, including cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM), the novel AHTN molecularly imprinted sensor (AHTN-MIP/G/GCE) has been demonstrated to be an effective tool for monitoring AHTN. The results demonstrate that the linear detection range of the current response of the AHTN-MIP/G/GCE <sup>1</sup>electrode to AHTN was 0.01 μM–4 μM (i.e., 2.584 μg/L-1033.6 μg/L), with a detection limit of 2.3 × 10⁻⁹ M (i.e., 594.32 ng/L), following the optimization of the experimental conditions. Furthermore, the new sensor was successfully employed for the detection of AHTN in water samples, with recoveries of 97.1%–108.2 % with the added standards. Consequently, the new electrochemical sensor demonstrated good stability and acceptable reproducibility. This study provides a new method for the future detection of AHTN in the aqueous environment.</div></div>","PeriodicalId":7830,"journal":{"name":"Analytical biochemistry","volume":"698 ","pages":"Article 115730"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical biochemistry","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003269724002744","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Given the adverse effects of tonalide (AHTN) on aquatic organisms and humans, coupled with the limitations of current detection methods, which are time-consuming, require expensive equipment and complicated sample preparation procedures, there is a clear need to develop a new technique for detecting AHTN that is highly sensitive, rapid, cost-effective and efficient. In this study, a new simple electrochemical sensor for the determination of AHTN in aqueous environments was developed for the first time through the in-situ polymerization of an AHTN-imprinted polymer on the surface of a graphene (G)-modified carbon electrode (GCE). Following a series of comparative tests, including cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM), the novel AHTN molecularly imprinted sensor (AHTN-MIP/G/GCE) has been demonstrated to be an effective tool for monitoring AHTN. The results demonstrate that the linear detection range of the current response of the AHTN-MIP/G/GCE 1electrode to AHTN was 0.01 μM–4 μM (i.e., 2.584 μg/L-1033.6 μg/L), with a detection limit of 2.3 × 10⁻⁹ M (i.e., 594.32 ng/L), following the optimization of the experimental conditions. Furthermore, the new sensor was successfully employed for the detection of AHTN in water samples, with recoveries of 97.1%–108.2 % with the added standards. Consequently, the new electrochemical sensor demonstrated good stability and acceptable reproducibility. This study provides a new method for the future detection of AHTN in the aqueous environment.
期刊介绍:
The journal''s title Analytical Biochemistry: Methods in the Biological Sciences declares its broad scope: methods for the basic biological sciences that include biochemistry, molecular genetics, cell biology, proteomics, immunology, bioinformatics and wherever the frontiers of research take the field.
The emphasis is on methods from the strictly analytical to the more preparative that would include novel approaches to protein purification as well as improvements in cell and organ culture. The actual techniques are equally inclusive ranging from aptamers to zymology.
The journal has been particularly active in:
-Analytical techniques for biological molecules-
Aptamer selection and utilization-
Biosensors-
Chromatography-
Cloning, sequencing and mutagenesis-
Electrochemical methods-
Electrophoresis-
Enzyme characterization methods-
Immunological approaches-
Mass spectrometry of proteins and nucleic acids-
Metabolomics-
Nano level techniques-
Optical spectroscopy in all its forms.
The journal is reluctant to include most drug and strictly clinical studies as there are more suitable publication platforms for these types of papers.