Thermal-mechanical behavior of deeply buried pipe energy pile group in sand obtained from model test

IF 6.1 2区 工程技术 Q2 ENERGY & FUELS
Jianghuai Yuan , Zhi Chen , Henglin Xiao , Lifei Zheng , Wentao Li , Xugen Song
{"title":"Thermal-mechanical behavior of deeply buried pipe energy pile group in sand obtained from model test","authors":"Jianghuai Yuan ,&nbsp;Zhi Chen ,&nbsp;Henglin Xiao ,&nbsp;Lifei Zheng ,&nbsp;Wentao Li ,&nbsp;Xugen Song","doi":"10.1016/j.applthermaleng.2024.125078","DOIUrl":null,"url":null,"abstract":"<div><div>One practical and effective method for shallow geothermal development is energy piling. This research presents the deeply buried pipe energy pile (DBP-EP), which has a wide range of potential applications and can collect deeper geothermal heat from the pile toe. This work conducts a model test investigation of the thermal–mechanical behavior of the DBP-EP group in sandy soil because the construction of the former differs from that of the common inside buried pipe energy piles (IBP-EP). The findings indicate that the heat exchanger tube at the pile toe of DBP-EP will be extended outward for heat exchange with the soil, in contrast to IBP-EP, and that the temperature change at the pile toe is greater than that of the whole. The pile cross-section strain decreases gradually from inside to outside along the radial direction. The axial earth pressure change rule around the pile is larger at both ends and small in the middle. For every 1℃ that the inlet temperature raises, the pile top’s final displacement increases by roughly 0.11‰<span><math><mrow><mi>D</mi></mrow></math></span>. At various inlet temperatures, the DBP-EP group heat transfer rate per meter drops by 8% − 23% when compared to the single pile’s. The average axial earth pressure difference surrounding the pile gradually rises when the pile top is not loaded, while the pile side friction difference of the pile group reduces in comparison to that of the single pile. The variations in pile side friction, axial earth pressure surrounding the pile, and pile top displacement of the pile group are reduced when the pile top is loaded because of the dense effect between the pile and the soil. This study contributes to the theoretical understanding of the design and practical implementation of DBP-EP structures.</div></div>","PeriodicalId":8201,"journal":{"name":"Applied Thermal Engineering","volume":"261 ","pages":"Article 125078"},"PeriodicalIF":6.1000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Thermal Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1359431124027467","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

One practical and effective method for shallow geothermal development is energy piling. This research presents the deeply buried pipe energy pile (DBP-EP), which has a wide range of potential applications and can collect deeper geothermal heat from the pile toe. This work conducts a model test investigation of the thermal–mechanical behavior of the DBP-EP group in sandy soil because the construction of the former differs from that of the common inside buried pipe energy piles (IBP-EP). The findings indicate that the heat exchanger tube at the pile toe of DBP-EP will be extended outward for heat exchange with the soil, in contrast to IBP-EP, and that the temperature change at the pile toe is greater than that of the whole. The pile cross-section strain decreases gradually from inside to outside along the radial direction. The axial earth pressure change rule around the pile is larger at both ends and small in the middle. For every 1℃ that the inlet temperature raises, the pile top’s final displacement increases by roughly 0.11‰D. At various inlet temperatures, the DBP-EP group heat transfer rate per meter drops by 8% − 23% when compared to the single pile’s. The average axial earth pressure difference surrounding the pile gradually rises when the pile top is not loaded, while the pile side friction difference of the pile group reduces in comparison to that of the single pile. The variations in pile side friction, axial earth pressure surrounding the pile, and pile top displacement of the pile group are reduced when the pile top is loaded because of the dense effect between the pile and the soil. This study contributes to the theoretical understanding of the design and practical implementation of DBP-EP structures.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Thermal Engineering
Applied Thermal Engineering 工程技术-工程:机械
CiteScore
11.30
自引率
15.60%
发文量
1474
审稿时长
57 days
期刊介绍: Applied Thermal Engineering disseminates novel research related to the design, development and demonstration of components, devices, equipment, technologies and systems involving thermal processes for the production, storage, utilization and conservation of energy, with a focus on engineering application. The journal publishes high-quality and high-impact Original Research Articles, Review Articles, Short Communications and Letters to the Editor on cutting-edge innovations in research, and recent advances or issues of interest to the thermal engineering community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信