An OPRM1-SNAP-tag/CMC method to directly identify drug components in sewage.

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
Chenjia Li, Qi Liao, Rui Wang, Xinping Zhang, Mengyang Ma, Yonghong Liu, Lei Xiao, Ying Jiao, Nan Wang
{"title":"An OPRM1-SNAP-tag/CMC method to directly identify drug components in sewage.","authors":"Chenjia Li, Qi Liao, Rui Wang, Xinping Zhang, Mengyang Ma, Yonghong Liu, Lei Xiao, Ying Jiao, Nan Wang","doi":"10.1007/s00216-024-05672-4","DOIUrl":null,"url":null,"abstract":"<p><p>The scourge of drug addiction and abuse poses a significant challenge to society. Opioid drugs acting on μ-opioid receptor (OPRM1) make it one of the pivotal targets for drug addiction. In the past decade, sewage analysis has become a prevalent method of drug monitoring. However, traditional methods of detecting drugs in sewage are cumbersome, and rapid detection methods are relatively lacking. To address this, an innovative OPRM1-SNAP-tag/CMC method to directly identify drug components in sewage was established. Cell membrane chromatography (CMC) is an affinity chromatography technique which effectively detects receptor affinity substances. Cells constructed with high expression of specific receptor could be used to screen for compounds acting on the receptor. CMC based on OPRM1 provides a potentially convenient and effective tool for the detection of targeted drug components in sewage. In this study, the selectivity, reproducibility, column lifetime, and carryover of the CMC column had been assessed. Initially, we eluted the collected domestic sewage with methanol and acetonitrile, and the retention peaks were observed on the CMC system. Subsequently, without any preliminary sample preparation, we directly injected filtered samples of suspicious sewage into the OPRM1-SNAP-tag/CMC system, where we observed retention peaks as well. The retained components were further identified as morphine by using UPLC-MS/MS. In conclusion, the OPRM1-SNAP-tag/CMC method stands out as a reliable and robust model for the detection of drug components in sewage. It provides a valuable analytical tool for frontline drug control efforts, enhancing our capacity to monitor and mitigate the impact of drug abuse on society.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05672-4","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The scourge of drug addiction and abuse poses a significant challenge to society. Opioid drugs acting on μ-opioid receptor (OPRM1) make it one of the pivotal targets for drug addiction. In the past decade, sewage analysis has become a prevalent method of drug monitoring. However, traditional methods of detecting drugs in sewage are cumbersome, and rapid detection methods are relatively lacking. To address this, an innovative OPRM1-SNAP-tag/CMC method to directly identify drug components in sewage was established. Cell membrane chromatography (CMC) is an affinity chromatography technique which effectively detects receptor affinity substances. Cells constructed with high expression of specific receptor could be used to screen for compounds acting on the receptor. CMC based on OPRM1 provides a potentially convenient and effective tool for the detection of targeted drug components in sewage. In this study, the selectivity, reproducibility, column lifetime, and carryover of the CMC column had been assessed. Initially, we eluted the collected domestic sewage with methanol and acetonitrile, and the retention peaks were observed on the CMC system. Subsequently, without any preliminary sample preparation, we directly injected filtered samples of suspicious sewage into the OPRM1-SNAP-tag/CMC system, where we observed retention peaks as well. The retained components were further identified as morphine by using UPLC-MS/MS. In conclusion, the OPRM1-SNAP-tag/CMC method stands out as a reliable and robust model for the detection of drug components in sewage. It provides a valuable analytical tool for frontline drug control efforts, enhancing our capacity to monitor and mitigate the impact of drug abuse on society.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
638
审稿时长
2.1 months
期刊介绍: Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信