Copper-enriched hydroxyapatite coatings obtained by high-velocity suspension flame spraying. Effect of various gas parameters on biocompatibility

IF 4.2 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Long-Quan R. V. Le, M. Carolina Lanzino, Matthias Blum, Anika Höppel, Ali Al-Ahmad, Andreas Killinger, Rainer Gadow, Wolfgang Rheinheimer, Michael Seidenstuecker
{"title":"Copper-enriched hydroxyapatite coatings obtained by high-velocity suspension flame spraying. Effect of various gas parameters on biocompatibility","authors":"Long-Quan R. V. Le,&nbsp;M. Carolina Lanzino,&nbsp;Matthias Blum,&nbsp;Anika Höppel,&nbsp;Ali Al-Ahmad,&nbsp;Andreas Killinger,&nbsp;Rainer Gadow,&nbsp;Wolfgang Rheinheimer,&nbsp;Michael Seidenstuecker","doi":"10.1007/s10856-024-06846-3","DOIUrl":null,"url":null,"abstract":"<div><p>Hydroxyapatite (HAp)-coated bone implants are frequently used for orthopaedic or dental implants since they offer high biocompatibility and osteoconductivity. Yet, problems such as infections, e.g. periprosthetic joint infections, occur when implanting foreign material into the body. In this study, HAp coatings were produced via high-velocity suspension flame spraying (HVSFS). This method allows for the production of thin coatings. We investigated the effects of different gas parameters on the coating properties and on the biocompatibility, which was tested on the human osteosarcoma cell line MG63. Furthermore, Copper (Cu) was added to achieve antibacterial properties which were evaluated against standard microorganisms using the airborne assay. Three gas parameter groups (low, medium, and high) with different Cu additions (0 wt.%, 1 wt.% and 1.5 wt.%) were evaluated. Our findings show that porosity as well as hardness can be controlled through gas parameters. Furthermore, we showed that it is possible to add Cu through external injection. The Cu content in the coating as well as the release varies with different gas parameters. Both antibacterial efficacy as well as biocompatibility are affected by the Cu content. We could significantly reduce the amount of colony-forming units (CFU) in all coatings for <i>E. coli</i>, CFU for <i>S. aureus</i> was reduced by adding 1.5 wt.% of Cu to the coating. The biocompatibility testing showed a cytotoxicity threshold at a Cu-release of 14.3 mg/L in 120 hours. Based on our findings, we suggest medium gas parameters for HVSFS and the addition of 1 wt.% Cu to the coating. With these parameters, a reasonable antibacterial effect can be achieved while maintaining sufficient biocompatibility.</p><h3>Graphical Abstract</h3><div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":647,"journal":{"name":"Journal of Materials Science: Materials in Medicine","volume":"35 1","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10856-024-06846-3.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Science: Materials in Medicine","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10856-024-06846-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Hydroxyapatite (HAp)-coated bone implants are frequently used for orthopaedic or dental implants since they offer high biocompatibility and osteoconductivity. Yet, problems such as infections, e.g. periprosthetic joint infections, occur when implanting foreign material into the body. In this study, HAp coatings were produced via high-velocity suspension flame spraying (HVSFS). This method allows for the production of thin coatings. We investigated the effects of different gas parameters on the coating properties and on the biocompatibility, which was tested on the human osteosarcoma cell line MG63. Furthermore, Copper (Cu) was added to achieve antibacterial properties which were evaluated against standard microorganisms using the airborne assay. Three gas parameter groups (low, medium, and high) with different Cu additions (0 wt.%, 1 wt.% and 1.5 wt.%) were evaluated. Our findings show that porosity as well as hardness can be controlled through gas parameters. Furthermore, we showed that it is possible to add Cu through external injection. The Cu content in the coating as well as the release varies with different gas parameters. Both antibacterial efficacy as well as biocompatibility are affected by the Cu content. We could significantly reduce the amount of colony-forming units (CFU) in all coatings for E. coli, CFU for S. aureus was reduced by adding 1.5 wt.% of Cu to the coating. The biocompatibility testing showed a cytotoxicity threshold at a Cu-release of 14.3 mg/L in 120 hours. Based on our findings, we suggest medium gas parameters for HVSFS and the addition of 1 wt.% Cu to the coating. With these parameters, a reasonable antibacterial effect can be achieved while maintaining sufficient biocompatibility.

Graphical Abstract

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Materials Science: Materials in Medicine
Journal of Materials Science: Materials in Medicine 工程技术-材料科学:生物材料
CiteScore
8.00
自引率
0.00%
发文量
73
审稿时长
3.5 months
期刊介绍: The Journal of Materials Science: Materials in Medicine publishes refereed papers providing significant progress in the application of biomaterials and tissue engineering constructs as medical or dental implants, prostheses and devices. Coverage spans a wide range of topics from basic science to clinical applications, around the theme of materials in medicine and dentistry. The central element is the development of synthetic and natural materials used in orthopaedic, maxillofacial, cardiovascular, neurological, ophthalmic and dental applications. Special biomedical topics include biomaterial synthesis and characterisation, biocompatibility studies, nanomedicine, tissue engineering constructs and cell substrates, regenerative medicine, computer modelling and other advanced experimental methodologies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信