Real-time diagnosis of sampled lesions in targeted biopsy of prostate Cancer using a novel tracer [64Cu] Cu-DOTA-PSMA-3Q: a pilot preclinical study

IF 8.6 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Jingfeng Zhang, Shaoxi Niu, Yachao Liu, Xiaojun Zhang, Xiaohui Luan, Huanhuan Liu, Yue Pan, Xiaodan Xu, Shina Wu, Yuan Wang, Zhiqiang Chen, Baojun Wang, Xu Zhang, Ruimin Wang, Jinming Zhang, Baixuan Xu
{"title":"Real-time diagnosis of sampled lesions in targeted biopsy of prostate Cancer using a novel tracer [64Cu] Cu-DOTA-PSMA-3Q: a pilot preclinical study","authors":"Jingfeng Zhang, Shaoxi Niu, Yachao Liu, Xiaojun Zhang, Xiaohui Luan, Huanhuan Liu, Yue Pan, Xiaodan Xu, Shina Wu, Yuan Wang, Zhiqiang Chen, Baojun Wang, Xu Zhang, Ruimin Wang, Jinming Zhang, Baixuan Xu","doi":"10.1007/s00259-024-07000-5","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>Prostate-specific membrane antigen positron emission tomography (PSMA-PET) guided targeted biopsy has shown potential for detecting more prostate cancer (PCa) cases. However, relying exclusively on imaging may risk missing lesions, an issue that could be addressed by incorporating radiation-guided technology. Accordingly, we aimed to develop a novel PSMA radiotracer with a long half-life, <b>[</b><sup><b>64</b></sup><b>Cu]</b>Cu-DOTA-PSMA-3Q, and evaluate its targeting accuracy. Additionally, this research explored the practicability of real-time lesion verification during surgical interventions.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>In this study, we synthesized the radiotracer <b>[</b><sup><b>64</b></sup><b>Cu]</b>Cu-DOTA-PSMA-3Q and verified its PSMA specificity and safety. We prospectively enrolled 18 patients with suspected PCa for PET/CT imaging to assess the efficacy of PCa detection; 10 patients underwent targeted biopsy combined with standard template biopsy at an interval of 24 h after injection. The radioactivity of the biopsy tissue was quantified in counts per minute (CPM) using a gamma spectrometer intraoperatively.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>The efficacy and specificity of <b>[</b><sup><b>64</b></sup><b>Cu]</b>Cu-DOTA-PSMA-3Q were confirmed through preclinical cell and animal studies. In clinical settings, PET/CT imaging performed 2 h after injection visualized all of the PSMA-positive lesions both within and outside the prostate. The assessment of human organ radiation exposure indicated that the kidneys received the highest absorbed dose, followed by the bladder wall, salivary glands, and liver. In 10 patients, a total of 132 biopsy cores were extracted, with 53 cores histologically confirmed as PCa. The median CPM for PCa tissues was significantly greater at 134,148 CPM compared to 18,39 CPM for normal prostate tissues (<i>P</i> &lt; 0.001). Receiver operating characteristic (ROC) curve analysis yielded an AUC of 0.8837, suggesting high diagnostic accuracy. The optimal diagnostic cut-off was established at 66 CPM, achieving a sensitivity of 77.36%.</p><h3 data-test=\"abstract-sub-heading\">Conclusions</h3><p>Radiation-guided technology using <b>[</b><sup><b>64</b></sup><b>Cu]</b>Cu-DOTA-PSMA-3Q improves the reliability of PSMA-PET image-guided biopsy, enables instant confirmation of sample lesions during surgical procedures, and holds potential for achieving optimized puncture outcomes.</p><h3 data-test=\"abstract-sub-heading\">Trial registration</h3><p>Chinese Clinical Trial Registry ChiCTR2300072655, Registered 20 June 2023.</p>","PeriodicalId":11909,"journal":{"name":"European Journal of Nuclear Medicine and Molecular Imaging","volume":"37 1","pages":""},"PeriodicalIF":8.6000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Nuclear Medicine and Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00259-024-07000-5","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Prostate-specific membrane antigen positron emission tomography (PSMA-PET) guided targeted biopsy has shown potential for detecting more prostate cancer (PCa) cases. However, relying exclusively on imaging may risk missing lesions, an issue that could be addressed by incorporating radiation-guided technology. Accordingly, we aimed to develop a novel PSMA radiotracer with a long half-life, [64Cu]Cu-DOTA-PSMA-3Q, and evaluate its targeting accuracy. Additionally, this research explored the practicability of real-time lesion verification during surgical interventions.

Methods

In this study, we synthesized the radiotracer [64Cu]Cu-DOTA-PSMA-3Q and verified its PSMA specificity and safety. We prospectively enrolled 18 patients with suspected PCa for PET/CT imaging to assess the efficacy of PCa detection; 10 patients underwent targeted biopsy combined with standard template biopsy at an interval of 24 h after injection. The radioactivity of the biopsy tissue was quantified in counts per minute (CPM) using a gamma spectrometer intraoperatively.

Results

The efficacy and specificity of [64Cu]Cu-DOTA-PSMA-3Q were confirmed through preclinical cell and animal studies. In clinical settings, PET/CT imaging performed 2 h after injection visualized all of the PSMA-positive lesions both within and outside the prostate. The assessment of human organ radiation exposure indicated that the kidneys received the highest absorbed dose, followed by the bladder wall, salivary glands, and liver. In 10 patients, a total of 132 biopsy cores were extracted, with 53 cores histologically confirmed as PCa. The median CPM for PCa tissues was significantly greater at 134,148 CPM compared to 18,39 CPM for normal prostate tissues (P < 0.001). Receiver operating characteristic (ROC) curve analysis yielded an AUC of 0.8837, suggesting high diagnostic accuracy. The optimal diagnostic cut-off was established at 66 CPM, achieving a sensitivity of 77.36%.

Conclusions

Radiation-guided technology using [64Cu]Cu-DOTA-PSMA-3Q improves the reliability of PSMA-PET image-guided biopsy, enables instant confirmation of sample lesions during surgical procedures, and holds potential for achieving optimized puncture outcomes.

Trial registration

Chinese Clinical Trial Registry ChiCTR2300072655, Registered 20 June 2023.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
15.60
自引率
9.90%
发文量
392
审稿时长
3 months
期刊介绍: The European Journal of Nuclear Medicine and Molecular Imaging serves as a platform for the exchange of clinical and scientific information within nuclear medicine and related professions. It welcomes international submissions from professionals involved in the functional, metabolic, and molecular investigation of diseases. The journal's coverage spans physics, dosimetry, radiation biology, radiochemistry, and pharmacy, providing high-quality peer review by experts in the field. Known for highly cited and downloaded articles, it ensures global visibility for research work and is part of the EJNMMI journal family.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信