Peak V̇O2 during handcycling in spinal cord injured athletes: incremental versus verification testing.

Caio de Araújo Rosa, Diego Antunes, Thiago Pereira Ventura, Gabriela Fischer, Gary Brickley, Ricardo Dantas de Lucas, Tiago Turnes
{"title":"Peak V̇O<sub>2</sub> during handcycling in spinal cord injured athletes: incremental versus verification testing.","authors":"Caio de Araújo Rosa, Diego Antunes, Thiago Pereira Ventura, Gabriela Fischer, Gary Brickley, Ricardo Dantas de Lucas, Tiago Turnes","doi":"10.1139/apnm-2024-0193","DOIUrl":null,"url":null,"abstract":"<p><p>The present study aimed to compare peak oxygen uptake (V̇O<sub>2</sub>peak), peak heart rate (HRpeak), and peak O<sub>2</sub>pulse during an incremental and a verification test performed on the same day in hand-cyclists with spinal cord injury (SCI). Eight competitive SCI hand-cyclists (age: 23 ± 2.7 years; V̇O<sub>2</sub>peak: 36.3 ± 14.0 mL.kg<sup>-1</sup>.min<sup>-1</sup>) performed a maximal incremental handcycling test and a verification test to exhaustion at 100% of the peak speed on an oversized treadmill. The V̇O<sub>2</sub>peak, HRpeak, and peak O<sub>2</sub>pulse (i.e., VO<sub>2</sub>/HR) were compared between incremental and verification tests. Absolute and relative V̇O<sub>2</sub>peak obtained in the verification test (2.51 ± 0.96 L.min<sup>-1</sup>; 36.3 ± 14.0 mL.kg.min<sup>-1</sup>) were significantly higher than values obtained in the incremental test (2.24 ± 0.79 L.min<sup>-1</sup>; 33.5 ± 12.9 mL.kg.min<sup>-1</sup>; <i>P</i> < 0.05). The mean differences (95% CL) of absolute and relative V̇O<sub>2</sub>peak between tests were 8.2% (3.3%-13.2%) and 10.9% (4.3%-18.1%), respectively. There was no difference in HR peak (incremental: 169 ± 24 bpm; verification 167 ± 25 bpm; <i>P</i> = 0.130). Peak O<sub>2</sub>pulse from the verification test (14.6 ± 4.7 mL.beat<sup>-1</sup>) was higher than incremental test (13.0 ± 3.8 mL.beat<sup>-1</sup>; <i>P</i> = 0.007). In conclusion, the verification test elicited greater V̇O<sub>2</sub>peak and O<sub>2</sub>pulse than a two-phase incremental test despite the similar HRpeak. This indicates that for this progressive protocol lasting ≥25 min, the verification phase adds value to determining V̇O<sub>2</sub>peak in SCI athletes.</p>","PeriodicalId":93878,"journal":{"name":"Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme","volume":" ","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1139/apnm-2024-0193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The present study aimed to compare peak oxygen uptake (V̇O2peak), peak heart rate (HRpeak), and peak O2pulse during an incremental and a verification test performed on the same day in hand-cyclists with spinal cord injury (SCI). Eight competitive SCI hand-cyclists (age: 23 ± 2.7 years; V̇O2peak: 36.3 ± 14.0 mL.kg-1.min-1) performed a maximal incremental handcycling test and a verification test to exhaustion at 100% of the peak speed on an oversized treadmill. The V̇O2peak, HRpeak, and peak O2pulse (i.e., VO2/HR) were compared between incremental and verification tests. Absolute and relative V̇O2peak obtained in the verification test (2.51 ± 0.96 L.min-1; 36.3 ± 14.0 mL.kg.min-1) were significantly higher than values obtained in the incremental test (2.24 ± 0.79 L.min-1; 33.5 ± 12.9 mL.kg.min-1; P < 0.05). The mean differences (95% CL) of absolute and relative V̇O2peak between tests were 8.2% (3.3%-13.2%) and 10.9% (4.3%-18.1%), respectively. There was no difference in HR peak (incremental: 169 ± 24 bpm; verification 167 ± 25 bpm; P = 0.130). Peak O2pulse from the verification test (14.6 ± 4.7 mL.beat-1) was higher than incremental test (13.0 ± 3.8 mL.beat-1; P = 0.007). In conclusion, the verification test elicited greater V̇O2peak and O2pulse than a two-phase incremental test despite the similar HRpeak. This indicates that for this progressive protocol lasting ≥25 min, the verification phase adds value to determining V̇O2peak in SCI athletes.

脊髓损伤运动员手骑时的峰值V / O2:增量试验与验证试验。
本研究旨在比较脊髓损伤(SCI)手骑自行车者在同一天进行的增量试验和验证试验中的峰值摄氧量(V O2峰值)、峰值心率(HRpeak)和峰值氧脉冲。8名SCI手单车选手(年龄:23±2.7岁;V / o峰值:2.24±0.79 l.min-1或36.3±14.0 ml.kg-1 min-1)在超大型跑步机上进行最大增量手扶试验和100% V / o峰值速度下的疲劳验证试验。比较增量试验和验证试验的V / o2峰、hr峰和峰值o2脉冲(即VO2/HR)。验证试验获得的V (o2)峰值(2.51±0.96 l.min-1)显著高于增量试验获得的值(2.24±0.79 l.min-1);P = 0.018)。两组心率峰值无差异(增量:169±24 bpm;验证167±25 bpm;P = 0.130)。验证试验的峰值o2脉冲(14.6±4.7 ml.beat-1)高于增量试验(13.0±3.8 ml.beat-1);P = 0.007)。与增量练习相比,验证测试中有6名受试者的变异性大于±4%。综上所述,在HR相似的情况下,验证试验获得的V o 2峰值高于增量试验,提示验证阶段与脊髓损伤手骑者的V o 2峰值确定有相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信