Assessment of multi-factor influences on elderly usage patterns and heat-stress exposure in neighbourhood public outdoor spaces

IF 7.1 1区 工程技术 Q1 CONSTRUCTION & BUILDING TECHNOLOGY
Jiawei Wang, Jianong Li, Jianlei Niu
{"title":"Assessment of multi-factor influences on elderly usage patterns and heat-stress exposure in neighbourhood public outdoor spaces","authors":"Jiawei Wang,&nbsp;Jianong Li,&nbsp;Jianlei Niu","doi":"10.1016/j.buildenv.2024.112340","DOIUrl":null,"url":null,"abstract":"<div><div>Given the hotter weather in summer, quantifying the impacts of thermal and non-thermal factors on the usage of public outdoor spaces (POS) and exposure to heat stress among older people are essential to evaluate heat-related risks in POS and guide POS designs to guarantee the safety of outdoor activities. In this study, field tests were conducted from June to August in four POS of two public housing estates in Hong Kong, to investigate the elderly's POS usage and thermal response in relation to microclimate parameters, POS exercise function, and companionship. A method for evaluating the intensity of health-warning-heat-stress exposure in POS is proposed, aiming to guide risk reducing measures in POS. The results indicate that, at air temperatures within the 29.0 °C and 35.0 °C range, one-degree increase in mean radiant temperature is associated with around 0.05 decrease in POS effective usage rate (<em>eff<sub>UR</sub></em>). The <em>eff<sub>UR</sub></em> is found less sensitive to wind conditions, while 67% of the interviewees prefer stronger wind speed. An average thermal sensation vote of 1 (slightly warm) and a fairly high <em>eff<sub>UR</sub></em> are found under a wide mPET range spanning from 30.0 °C to 39.0 °C, while moderate-to-strong heat stress may occur when mPET exceeds 35.0 °C. Elderly users’ thermal sensitivities reduce in POS providing exercise functions, and when in the company of and chatting with others. The intensity of health-warning-heat-stress exposure varies over time and differs across POS, which will be exacerbated due to global warming unless climate-adapted cooling strategies are implemented.</div></div>","PeriodicalId":9273,"journal":{"name":"Building and Environment","volume":"268 ","pages":"Article 112340"},"PeriodicalIF":7.1000,"publicationDate":"2024-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building and Environment","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S036013232401182X","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Given the hotter weather in summer, quantifying the impacts of thermal and non-thermal factors on the usage of public outdoor spaces (POS) and exposure to heat stress among older people are essential to evaluate heat-related risks in POS and guide POS designs to guarantee the safety of outdoor activities. In this study, field tests were conducted from June to August in four POS of two public housing estates in Hong Kong, to investigate the elderly's POS usage and thermal response in relation to microclimate parameters, POS exercise function, and companionship. A method for evaluating the intensity of health-warning-heat-stress exposure in POS is proposed, aiming to guide risk reducing measures in POS. The results indicate that, at air temperatures within the 29.0 °C and 35.0 °C range, one-degree increase in mean radiant temperature is associated with around 0.05 decrease in POS effective usage rate (effUR). The effUR is found less sensitive to wind conditions, while 67% of the interviewees prefer stronger wind speed. An average thermal sensation vote of 1 (slightly warm) and a fairly high effUR are found under a wide mPET range spanning from 30.0 °C to 39.0 °C, while moderate-to-strong heat stress may occur when mPET exceeds 35.0 °C. Elderly users’ thermal sensitivities reduce in POS providing exercise functions, and when in the company of and chatting with others. The intensity of health-warning-heat-stress exposure varies over time and differs across POS, which will be exacerbated due to global warming unless climate-adapted cooling strategies are implemented.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Building and Environment
Building and Environment 工程技术-工程:环境
CiteScore
12.50
自引率
23.00%
发文量
1130
审稿时长
27 days
期刊介绍: Building and Environment, an international journal, is dedicated to publishing original research papers, comprehensive review articles, editorials, and short communications in the fields of building science, urban physics, and human interaction with the indoor and outdoor built environment. The journal emphasizes innovative technologies and knowledge verified through measurement and analysis. It covers environmental performance across various spatial scales, from cities and communities to buildings and systems, fostering collaborative, multi-disciplinary research with broader significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信