Study of the temperature-humidity equivalence and the time-temperature superposition principle in the finite-strain response of polyamide-6 and short glass fibre-reinforced polyamide-6
IF 5 2区 材料科学Q1 MATERIALS SCIENCE, CHARACTERIZATION & TESTING
Daniele Finazzi , Guillem Seychal , Jean-Marie Raquez , Gilles Robert , Karen De Clerck , Lode Daelemans , Wim Van Paepegem
{"title":"Study of the temperature-humidity equivalence and the time-temperature superposition principle in the finite-strain response of polyamide-6 and short glass fibre-reinforced polyamide-6","authors":"Daniele Finazzi , Guillem Seychal , Jean-Marie Raquez , Gilles Robert , Karen De Clerck , Lode Daelemans , Wim Van Paepegem","doi":"10.1016/j.polymertesting.2024.108653","DOIUrl":null,"url":null,"abstract":"<div><div>Polyamide-6 (PA6) and short glass fibre-reinforced PA6 (GPA6) are increasingly used in structural automotive parts exposed to harsh conditions, respectively as liner in Type IV hydrogen tanks and under-the-hood components near the engine. Safe design requires understanding of their complex mechanical behaviour under the influence of temperature, moisture, and strain rate. Two models often applied in the literature are the temperature-humidity equivalence and the time-temperature superposition (TTS), however their accuracy to describe the full mechanical response is still unclear. By generating high-quality data, this paper conducts a quantitative study of these models on the mechanical response of injection-moulded PA6 and GPA6 with a very high fibre content (50 wt%). The materials were conditioned either dry or at 50%RH. Dynamic mechanical analysis (DMA) was used to measure the glass transition temperature of dry PA6 and 50%RH PA6, and to construct TTS master curves. Tensile tests were then conducted at different combinations of temperature, moisture, and strain rate. Comparison of the tensile true stress-true strain curves revealed that the proposed models fail to capture the effects of the thermal history, which may cause microstructural modifications as demonstrated with differential scanning calorimetry (DSC). The link between DSC, DMA, and tensile data constitutes a novelty of this work and was possible because all the samples had the same hygro-thermal history. Additionally, self-heating of PA6 causes deviations from the TTS at large strains. The results of this study may help develop more accurate material models, ultimately improving the design of structural automotive parts.</div></div>","PeriodicalId":20628,"journal":{"name":"Polymer Testing","volume":"141 ","pages":"Article 108653"},"PeriodicalIF":5.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polymer Testing","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142941824003301","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0
Abstract
Polyamide-6 (PA6) and short glass fibre-reinforced PA6 (GPA6) are increasingly used in structural automotive parts exposed to harsh conditions, respectively as liner in Type IV hydrogen tanks and under-the-hood components near the engine. Safe design requires understanding of their complex mechanical behaviour under the influence of temperature, moisture, and strain rate. Two models often applied in the literature are the temperature-humidity equivalence and the time-temperature superposition (TTS), however their accuracy to describe the full mechanical response is still unclear. By generating high-quality data, this paper conducts a quantitative study of these models on the mechanical response of injection-moulded PA6 and GPA6 with a very high fibre content (50 wt%). The materials were conditioned either dry or at 50%RH. Dynamic mechanical analysis (DMA) was used to measure the glass transition temperature of dry PA6 and 50%RH PA6, and to construct TTS master curves. Tensile tests were then conducted at different combinations of temperature, moisture, and strain rate. Comparison of the tensile true stress-true strain curves revealed that the proposed models fail to capture the effects of the thermal history, which may cause microstructural modifications as demonstrated with differential scanning calorimetry (DSC). The link between DSC, DMA, and tensile data constitutes a novelty of this work and was possible because all the samples had the same hygro-thermal history. Additionally, self-heating of PA6 causes deviations from the TTS at large strains. The results of this study may help develop more accurate material models, ultimately improving the design of structural automotive parts.
期刊介绍:
Polymer Testing focuses on the testing, analysis and characterization of polymer materials, including both synthetic and natural or biobased polymers. Novel testing methods and the testing of novel polymeric materials in bulk, solution and dispersion is covered. In addition, we welcome the submission of the testing of polymeric materials for a wide range of applications and industrial products as well as nanoscale characterization.
The scope includes but is not limited to the following main topics:
Novel testing methods and Chemical analysis
• mechanical, thermal, electrical, chemical, imaging, spectroscopy, scattering and rheology
Physical properties and behaviour of novel polymer systems
• nanoscale properties, morphology, transport properties
Degradation and recycling of polymeric materials when combined with novel testing or characterization methods
• degradation, biodegradation, ageing and fire retardancy
Modelling and Simulation work will be only considered when it is linked to new or previously published experimental results.