Experimental investigation of the effect of phase change material on backup time and equivalent energy consumption of domestic refrigerator

Laxman N. Mane, Pradeep A. Patil
{"title":"Experimental investigation of the effect of phase change material on backup time and equivalent energy consumption of domestic refrigerator","authors":"Laxman N. Mane,&nbsp;Pradeep A. Patil","doi":"10.1016/j.enss.2024.07.001","DOIUrl":null,"url":null,"abstract":"<div><div>Load shedding is a significant problem in rural areas. During a power outage, the cabin temperature of a refrigerator increases owing to the heat gain. In practice, a door should be opened to load and unload refrigerator products, particularly when the power failure period is longer. The use of a phase-change material (PCM) in the refrigerator cabin restricts the increase in temperature and provides a backup time that reduces energy consumption. Door-opening tests are essential during a power cut-off time to investigate the reduction in backup time owing to door openings. This article presents an experimental investigation on the influence of PCM masses of potassium chloride, sodium chloride, and sodium fluoride dissolved in water on the backup time and equivalent energy consumption of a domestic refrigerator for closed and open doors according to the standards IS 1476 and IEC 62552:2015. The backup time of closed-door tests was significantly increased by the PCM for all masses, i.e., between 15 and 200 min in absolute terms and between 14% and 182% in relative terms. The backup time for the closed-door tests was 1.8–1.03 times longer than that for the door-opening tests. The backup time of door-opening tests decreased significantly owing to heat entering the cabin for all masses, i.e., between 50 and 10 min in absolute terms and between 45.45% and 3.23% in relative terms. The equivalent energy consumption of a refrigerator decreased with an increase in PCM mass. In closed-door tests, it varied from 0.55 to 0.41 kWh. 6-1 h for the 0–1.75 kg mass of all tested PCMs. In the door-opening tests, the equivalent energy consumption increased owing to door opening. The equivalent energy consumption for the door-opening tests was 1.12–1.02 times larger than that for the closed-door tests.</div></div>","PeriodicalId":100472,"journal":{"name":"Energy Storage and Saving","volume":"3 4","pages":"Pages 250-258"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Storage and Saving","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772683524000311","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Load shedding is a significant problem in rural areas. During a power outage, the cabin temperature of a refrigerator increases owing to the heat gain. In practice, a door should be opened to load and unload refrigerator products, particularly when the power failure period is longer. The use of a phase-change material (PCM) in the refrigerator cabin restricts the increase in temperature and provides a backup time that reduces energy consumption. Door-opening tests are essential during a power cut-off time to investigate the reduction in backup time owing to door openings. This article presents an experimental investigation on the influence of PCM masses of potassium chloride, sodium chloride, and sodium fluoride dissolved in water on the backup time and equivalent energy consumption of a domestic refrigerator for closed and open doors according to the standards IS 1476 and IEC 62552:2015. The backup time of closed-door tests was significantly increased by the PCM for all masses, i.e., between 15 and 200 min in absolute terms and between 14% and 182% in relative terms. The backup time for the closed-door tests was 1.8–1.03 times longer than that for the door-opening tests. The backup time of door-opening tests decreased significantly owing to heat entering the cabin for all masses, i.e., between 50 and 10 min in absolute terms and between 45.45% and 3.23% in relative terms. The equivalent energy consumption of a refrigerator decreased with an increase in PCM mass. In closed-door tests, it varied from 0.55 to 0.41 kWh. 6-1 h for the 0–1.75 kg mass of all tested PCMs. In the door-opening tests, the equivalent energy consumption increased owing to door opening. The equivalent energy consumption for the door-opening tests was 1.12–1.02 times larger than that for the closed-door tests.
相变材料对家用冰箱备用时间和等效能耗影响的实验研究
减载是农村地区的一个重大问题。在停电期间,由于热量的增加,冰箱的舱内温度升高。在实际操作中,特别是在停电时间较长的情况下,应打开箱门装卸冰箱产品。在冷冻室中使用相变材料(PCM)限制了温度的升高,并提供了减少能耗的备用时间。在断电期间,为了研究由于开门而减少的备用时间,开门试验是必不可少的。根据IS 1476和IEC 62552:2015标准,对溶解在水中的氯化钾、氯化钠和氟化钠的PCM质量对家用闭门和开门冰箱备用时间和等效能耗的影响进行了实验研究。所有质量的闭门试验后备时间均因PCM而显著增加,即绝对时间在15 ~ 200 min之间,相对时间在14% ~ 182%之间。闭门试验的备用时间是开门试验的1.8 ~ 1.03倍。由于热进入舱室,所有质量的开门试验备用时间均显著减少,即绝对时间在50 ~ 10 min之间,相对时间在45.45% ~ 3.23%之间。制冷机的等效能耗随着PCM质量的增加而降低。在闭门测试中,它在0.55到0.41千瓦时之间变化。所有测试的PCMs质量为0-1.75 kg时为6-1 h。在开门试验中,开门会增加等效能耗。开门试验的等效能耗是关门试验的1.12-1.02倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.70
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信