Hydromagnetic blood flow through a channel of varying width bounded by porous media of finite thickness

Q1 Mathematics
K. Ramakrishnan , Furqan Ahmad , M. Waqas , Barno Abdullaeva
{"title":"Hydromagnetic blood flow through a channel of varying width bounded by porous media of finite thickness","authors":"K. Ramakrishnan ,&nbsp;Furqan Ahmad ,&nbsp;M. Waqas ,&nbsp;Barno Abdullaeva","doi":"10.1016/j.padiff.2024.101000","DOIUrl":null,"url":null,"abstract":"<div><div>This study examines hydromagnetic blood flow through a channel with a varying width, bounded by porous media of finite thickness, using the Beavers–Joseph–Rudraiah slip conditions. In this context, the channel models blood flow, while the surrounding porous wall represents the tissue space. By utilizing power series approximations related to the wall slope, analytical expressions for flow characteristics including axial velocity in the x and y directions, wall momentum flux, resistance force, and shear stress are derived. These results are subsequently used to analyze blood flow through a smooth constriction surrounded by porous walls. The discussion centers on the effects of the magnetic field, slip parameter, and the width of the porous wall on flow resistance and the distribution of wall shear stress, while comparing these results with the Beavers–Joseph slip conditions. It is observed that flow resistance decreases with an increasing Hartmann number across different values of the porous parameter, which is consistent with the expectation that stronger magnetic fields reduce fluid motion and resistance. Moreover, shear stress decreases with a higher Hartmann number but increases with a larger porous parameter. Both the resistance force and shear stress are also influenced by the width of the porous walls. These findings have practical implications, particularly for evaluating the performance of prosthetic devices within the human body.</div></div>","PeriodicalId":34531,"journal":{"name":"Partial Differential Equations in Applied Mathematics","volume":"12 ","pages":"Article 101000"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Partial Differential Equations in Applied Mathematics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666818124003863","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0

Abstract

This study examines hydromagnetic blood flow through a channel with a varying width, bounded by porous media of finite thickness, using the Beavers–Joseph–Rudraiah slip conditions. In this context, the channel models blood flow, while the surrounding porous wall represents the tissue space. By utilizing power series approximations related to the wall slope, analytical expressions for flow characteristics including axial velocity in the x and y directions, wall momentum flux, resistance force, and shear stress are derived. These results are subsequently used to analyze blood flow through a smooth constriction surrounded by porous walls. The discussion centers on the effects of the magnetic field, slip parameter, and the width of the porous wall on flow resistance and the distribution of wall shear stress, while comparing these results with the Beavers–Joseph slip conditions. It is observed that flow resistance decreases with an increasing Hartmann number across different values of the porous parameter, which is consistent with the expectation that stronger magnetic fields reduce fluid motion and resistance. Moreover, shear stress decreases with a higher Hartmann number but increases with a larger porous parameter. Both the resistance force and shear stress are also influenced by the width of the porous walls. These findings have practical implications, particularly for evaluating the performance of prosthetic devices within the human body.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
0.00%
发文量
138
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信