{"title":"Virtual Reality Portable Perimetry and Home Monitoring of Glaucoma: Retention and Compliance over a 2-year Period","authors":"Runjie B. Shi MD, PhD ,&nbsp;Leo Y. Li-Han PhD ,&nbsp;Irfan N. Kherani MD, FRCSC ,&nbsp;Graham E. Trope PhD, FRCSC ,&nbsp;Yvonne M. Buys MD, FRCSC ,&nbsp;Willy Wong PhD ,&nbsp;Moshe Eizenman PhD","doi":"10.1016/j.xops.2024.100639","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To evaluate long-term retention, compliance, and performance of glaucoma patients using a virtual reality portable perimeter to monitor visual fields (VFs) at home.</div></div><div><h3>Design</h3><div>Prospective, longitudinal, cohort study.</div></div><div><h3>Subjects</h3><div>Twenty-five glaucoma patients with stable and reliable VFs (average age 67.4 years) were recruited at Toronto Western Hospital, Ontario, Canada.</div></div><div><h3>Methods</h3><div>Participants were instructed to perform bilateral home VF tests fortnightly for 2 years using the Toronto Portable Perimeter (TPP). Based on empirical home monitoring data, simulation analyses were conducted to evaluate the progression detection performance of high-frequency TPP testing.</div></div><div><h3>Main Outcome Measures</h3><div>Retention rates were calculated as the percentage of participants who performed ≥1 home VF test. Compliance rates measured the percentage of participants adhering to the recommended test frequency of every 2-month period. Visual field indices, test reliability, intertest variability, and the precision of estimating progression rate with TPP were compared to those with the Humphrey Field Analyzer (HFA). After 6 months, participants completed a questionnaire to evaluate their experiences and preferences. The years required to detect progression were also compared between HFA and TPP tests.</div></div><div><h3>Results</h3><div>Eighteen of the 25 participants (72%) completed ≥1 unsupervised VF test at home, with an average test frequency of 1.6 tests/month. Compliance decreased as the monitoring duration progressed, dropping from 83% (initial 2 months) to 11% (final 2 months). Unfamiliarity with technology and time constraints were identified as the main barriers to regular testing. Visual field indices of TPP home tests were strongly correlated with clinical results (<em>r</em> &gt; 0.900). Home testing significantly reduced intertest variability (<em>P</em> &lt; 0.001) and improved the precision of progression rate estimates (<em>P</em> &lt; 0.010). Participants overwhelmingly preferred home testing over clinic VF follow-ups (<em>P</em> &lt; 0.001). Simulations showed that TPP tests can significantly shorten the time to detect progression for different progression rates compared with clinical VF follow-up, even with compromised compliance.</div></div><div><h3>Conclusions</h3><div>Despite the small sample size, our study demonstrated that glaucoma patients could reliably perform VF tests at home over a 2-year period. However, issues with retention rate and compliance with long-term VF monitoring were observed in some participants. Nevertheless, high-quality VF data from home tests can provide supplementary information to improve the timely detection of VF progression.</div></div><div><h3>Financial Disclosure(s)</h3><div>The author(s) have no proprietary or commercial interest in any materials discussed in this article.</div></div>","PeriodicalId":74363,"journal":{"name":"Ophthalmology science","volume":"5 2","pages":"Article 100639"},"PeriodicalIF":3.2000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666914524001751","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To evaluate long-term retention, compliance, and performance of glaucoma patients using a virtual reality portable perimeter to monitor visual fields (VFs) at home.

Design

Prospective, longitudinal, cohort study.

Subjects

Twenty-five glaucoma patients with stable and reliable VFs (average age 67.4 years) were recruited at Toronto Western Hospital, Ontario, Canada.

Methods

Participants were instructed to perform bilateral home VF tests fortnightly for 2 years using the Toronto Portable Perimeter (TPP). Based on empirical home monitoring data, simulation analyses were conducted to evaluate the progression detection performance of high-frequency TPP testing.

Main Outcome Measures

Retention rates were calculated as the percentage of participants who performed ≥1 home VF test. Compliance rates measured the percentage of participants adhering to the recommended test frequency of every 2-month period. Visual field indices, test reliability, intertest variability, and the precision of estimating progression rate with TPP were compared to those with the Humphrey Field Analyzer (HFA). After 6 months, participants completed a questionnaire to evaluate their experiences and preferences. The years required to detect progression were also compared between HFA and TPP tests.

Results

Eighteen of the 25 participants (72%) completed ≥1 unsupervised VF test at home, with an average test frequency of 1.6 tests/month. Compliance decreased as the monitoring duration progressed, dropping from 83% (initial 2 months) to 11% (final 2 months). Unfamiliarity with technology and time constraints were identified as the main barriers to regular testing. Visual field indices of TPP home tests were strongly correlated with clinical results (r > 0.900). Home testing significantly reduced intertest variability (P < 0.001) and improved the precision of progression rate estimates (P < 0.010). Participants overwhelmingly preferred home testing over clinic VF follow-ups (P < 0.001). Simulations showed that TPP tests can significantly shorten the time to detect progression for different progression rates compared with clinical VF follow-up, even with compromised compliance.

Conclusions

Despite the small sample size, our study demonstrated that glaucoma patients could reliably perform VF tests at home over a 2-year period. However, issues with retention rate and compliance with long-term VF monitoring were observed in some participants. Nevertheless, high-quality VF data from home tests can provide supplementary information to improve the timely detection of VF progression.

Financial Disclosure(s)

The author(s) have no proprietary or commercial interest in any materials discussed in this article.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ophthalmology science
Ophthalmology science Ophthalmology
CiteScore
3.40
自引率
0.00%
发文量
0
审稿时长
89 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信