Evaluation of the microbial contamination of the audiological diagnostic equipment and their current disinfection techniques.

IF 3.8 3区 医学 Q2 INFECTIOUS DISEASES
Bahtiyar Çelikgün, Furkan Büyükkal, M Esra Koçoğlu, M Tayyar Kalcioğlu, A Mehmet Akşit
{"title":"Evaluation of the microbial contamination of the audiological diagnostic equipment and their current disinfection techniques.","authors":"Bahtiyar Çelikgün, Furkan Büyükkal, M Esra Koçoğlu, M Tayyar Kalcioğlu, A Mehmet Akşit","doi":"10.1016/j.ajic.2024.11.014","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The study aims to investigate the microbial contamination of commonly used audiological diagnostic equipment and to evaluate the effectiveness of existing disinfection methods in audiological clinics.</p><p><strong>Methods: </strong>Hospitals with fully equipped audiology clinics in Istanbul were included in the study. Various audiological diagnostic devices and disinfection practices in hospitals were examined. A total of 60 swab samples were collected from the stimulus button on the audiometer, patient response switch, supra-aural headphone cushion, bone conduction headphone, and disinfected probe tips used in the Tympanometer and Auditory Brainstem Response.</p><p><strong>Results: </strong>Bacterial growth was observed on 40% of the analyzed plates, with 11.66% showing 2 different types of bacterial growth. Staphylococcaceae family were the most common bacteria identified. Other bacteria included Pseudomonas putida, Pantoea spp., Micrococcus luteus, Corynebacterium spp., and Bacillus spp. The highest bacterial growth occurred on the supra-aural headphone cushion and bone vibrator.</p><p><strong>Conclusions: </strong>The study highlights the presence of various bacteria on audiological diagnostic equipment, emphasizing Staphylococcus species as predominant. Current disinfection practices, particularly for supra-aural headphones and bone vibrators, were found to be inadequate, potentially posing risks for infections. The study suggests the need for disinfection protocols, particularly for frequently touched devices, to ensure patient safety in clinics.</p>","PeriodicalId":7621,"journal":{"name":"American journal of infection control","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of infection control","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.ajic.2024.11.014","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The study aims to investigate the microbial contamination of commonly used audiological diagnostic equipment and to evaluate the effectiveness of existing disinfection methods in audiological clinics.

Methods: Hospitals with fully equipped audiology clinics in Istanbul were included in the study. Various audiological diagnostic devices and disinfection practices in hospitals were examined. A total of 60 swab samples were collected from the stimulus button on the audiometer, patient response switch, supra-aural headphone cushion, bone conduction headphone, and disinfected probe tips used in the Tympanometer and Auditory Brainstem Response.

Results: Bacterial growth was observed on 40% of the analyzed plates, with 11.66% showing 2 different types of bacterial growth. Staphylococcaceae family were the most common bacteria identified. Other bacteria included Pseudomonas putida, Pantoea spp., Micrococcus luteus, Corynebacterium spp., and Bacillus spp. The highest bacterial growth occurred on the supra-aural headphone cushion and bone vibrator.

Conclusions: The study highlights the presence of various bacteria on audiological diagnostic equipment, emphasizing Staphylococcus species as predominant. Current disinfection practices, particularly for supra-aural headphones and bone vibrators, were found to be inadequate, potentially posing risks for infections. The study suggests the need for disinfection protocols, particularly for frequently touched devices, to ensure patient safety in clinics.

评估听力诊断设备的微生物污染及其当前的消毒技术。
背景:本研究旨在调查常用听力诊断设备的微生物污染情况,并评估听力诊所现有消毒方法的有效性。研究人员检查了各种听力诊断设备,如纯音听力计、鼓膜测听器和听性脑干反应(ABR)。研究还调查了医院的消毒方法。研究人员从听力计上的刺激按钮、患者反应开关、耳上耳机垫、骨传导耳机(骨振动器)以及鼓室听力计和听性脑干反应(ABR)中使用的消毒探头尖端共采集了 60 个棉签样本:在 40% 的分析平板上观察到细菌生长,其中 11.66% 的平板上有两种不同类型的细菌生长。葡萄球菌科细菌是最常见的细菌。其他细菌包括假单胞菌属(Pseudomonas putida)、假单胞菌属(Panteoa spp)、黄体微球菌属(Micrococcus luteus)、棒状杆菌属(Corynebacterium spp)和芽孢杆菌属(Bacillus spp):本研究强调听力诊断设备上存在各种细菌,其中以葡萄球菌为主。研究发现,目前的消毒方法,尤其是耳上耳机和骨振动器的消毒方法不够充分,可能会带来感染风险。研究表明,有必要制定消毒规程,尤其是针对经常接触的设备,以确保诊所中患者的安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.40
自引率
4.10%
发文量
479
审稿时长
24 days
期刊介绍: AJIC covers key topics and issues in infection control and epidemiology. Infection control professionals, including physicians, nurses, and epidemiologists, rely on AJIC for peer-reviewed articles covering clinical topics as well as original research. As the official publication of the Association for Professionals in Infection Control and Epidemiology (APIC)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信