Ultrasound visualization and blood flow velocity measurements of the adrenal arteries in the fetus.

IF 3.5 2区 医学 Q1 OBSTETRICS & GYNECOLOGY
Øystein Bergøy, Torvid Kiserud, Jørg Kessler, Ingvild Dalen, Kristine Moi Økland, Ragnar Kvie Sande
{"title":"Ultrasound visualization and blood flow velocity measurements of the adrenal arteries in the fetus.","authors":"Øystein Bergøy, Torvid Kiserud, Jørg Kessler, Ingvild Dalen, Kristine Moi Økland, Ragnar Kvie Sande","doi":"10.1111/aogs.15011","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Detection and surveillance of fetal growth restriction (FGR) is well established, but there is still room for improvement. Animal studies indicate that compromised fetuses increase adrenal blood flow. Modern ultrasound equipment allows us to measure vascular impedance in the fetal adrenal arteries despite their modest size. However, extensive anatomical variance is a challenge to standardizing measurements. We set out to improve this.</p><p><strong>Material and methods: </strong>We included 75 low-risk pregnant women in a prospective cross-sectional study aiming to develop a reliable technique to visualize and measure flow velocity in human fetal adrenal arteries. We used commercially available ultrasound equipment: a GE Voluson 10 2019 with a C2-9 probe (GE Healthcare, Zipf, Austria), and a Philips Epiq Elite with a V9-2 probe (Philips Medical Systems International B.V., Best, The Netherlands), exploiting the modern sensitive power Doppler modes in both scanners to visualize small vessels.</p><p><strong>Results: </strong>Among 72 fetuses, the inferior adrenal artery was the most consistently visualized and measured artery to the gland. Doppler velocimetry was achieved in 66 (92%) participants. We found the anatomical variation described previously but were able to develop visualization strategies to identify the common arteries and use a consistent Doppler technique for the second half of pregnancy.</p><p><strong>Conclusions: </strong>It is possible to visualize and measure flow velocity in the adrenal arteries of human fetuses. The success rate was highest for the inferior adrenal artery making this vessel a candidate for clinical studies.</p>","PeriodicalId":6990,"journal":{"name":"Acta Obstetricia et Gynecologica Scandinavica","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Obstetricia et Gynecologica Scandinavica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/aogs.15011","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Detection and surveillance of fetal growth restriction (FGR) is well established, but there is still room for improvement. Animal studies indicate that compromised fetuses increase adrenal blood flow. Modern ultrasound equipment allows us to measure vascular impedance in the fetal adrenal arteries despite their modest size. However, extensive anatomical variance is a challenge to standardizing measurements. We set out to improve this.

Material and methods: We included 75 low-risk pregnant women in a prospective cross-sectional study aiming to develop a reliable technique to visualize and measure flow velocity in human fetal adrenal arteries. We used commercially available ultrasound equipment: a GE Voluson 10 2019 with a C2-9 probe (GE Healthcare, Zipf, Austria), and a Philips Epiq Elite with a V9-2 probe (Philips Medical Systems International B.V., Best, The Netherlands), exploiting the modern sensitive power Doppler modes in both scanners to visualize small vessels.

Results: Among 72 fetuses, the inferior adrenal artery was the most consistently visualized and measured artery to the gland. Doppler velocimetry was achieved in 66 (92%) participants. We found the anatomical variation described previously but were able to develop visualization strategies to identify the common arteries and use a consistent Doppler technique for the second half of pregnancy.

Conclusions: It is possible to visualize and measure flow velocity in the adrenal arteries of human fetuses. The success rate was highest for the inferior adrenal artery making this vessel a candidate for clinical studies.

胎儿肾上腺动脉的超声可视化和血流速度测量。
导言:胎儿生长受限(FGR)的检测和监控已得到广泛认可,但仍有改进的余地。动物实验表明,胎儿发育受限会增加肾上腺血流量。尽管胎儿肾上腺动脉的体积不大,但现代超声设备可让我们测量其血管阻抗。然而,解剖学上的广泛差异是标准化测量的一个挑战。材料和方法:我们在一项前瞻性横断面研究中纳入了 75 名低风险孕妇,旨在开发一种可靠的技术来观察和测量胎儿肾上腺动脉的流速。我们使用了市售的超声设备:配有 C2-9 探头的 GE Voluson 10 2019(GE Healthcare,奥地利齐普夫)和配有 V9-2 探头的 Philips Epiq Elite(Philips Medical Systems International B.V.,荷兰贝斯特),利用这两种扫描仪的现代灵敏功率多普勒模式来观察小血管:结果:在 72 个胎儿中,肾上腺下动脉是最常被观察和测量到的通往腺体的动脉。有 66 名(92%)胎儿进行了多普勒测速。我们发现了之前描述过的解剖变异,但能够制定可视化策略来识别总动脉,并在妊娠后半期使用一致的多普勒技术:结论:观察和测量人类胎儿肾上腺动脉的流速是可能的。肾上腺下动脉的成功率最高,因此该血管可用于临床研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.00
自引率
4.70%
发文量
180
审稿时长
3-6 weeks
期刊介绍: Published monthly, Acta Obstetricia et Gynecologica Scandinavica is an international journal dedicated to providing the very latest information on the results of both clinical, basic and translational research work related to all aspects of women’s health from around the globe. The journal regularly publishes commentaries, reviews, and original articles on a wide variety of topics including: gynecology, pregnancy, birth, female urology, gynecologic oncology, fertility and reproductive biology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信