Replication of clinical prosthetic sockets for research purposes.

IF 0.8 4区 医学 Q4 ORTHOPEDICS
Alix Chadwell, Laurence Kenney, Michael Prince, Jennifer Olsen, Matthew Dyson
{"title":"Replication of clinical prosthetic sockets for research purposes.","authors":"Alix Chadwell, Laurence Kenney, Michael Prince, Jennifer Olsen, Matthew Dyson","doi":"10.1097/PXR.0000000000000386","DOIUrl":null,"url":null,"abstract":"<p><p>For research in the field of prosthetics to be representative of clinical realities, studies require inclusion of clinical standard prosthetic sockets. This necessitates involvement of a prosthetist (clinical professional) in any study, which is to truly explore the effectiveness of existing or novel prosthetic technologies. Unfortunately, there is a global shortage of prosthetists. With many technological advances in upper-limb prosthetics coming from engineering focused labs, it is unsurprising that studies are frequently conducted with anatomically intact individuals. In this paper, we present a method to clone the shape of a clinical standard prosthetic socket for research purposes. The technique uses silicone to capture the socket shape; this is then converted into a plaster mold, which can be used to manufacture an identically shaped socket using standard clinical manufacturing techniques. The whole process can be achieved without the involvement of a prosthetist. To validate the proposed technique, molds from an original socket and socket clone were 3D scanned. The distance between the aligned meshes were measured using CloudCompare software. The mean distance between the points on the 2 meshes was 0.16 mm (standard deviation 0.38 mm). This proof-of-concept study demonstrates that the proposed new approach to cloning a clinical standard prosthetic socket is feasible and accurate. This technique will facilitate improvements in the assessment of prosthetic technologies. The process is nondestructive, thus also opening opportunities for socket design and electrode placement research with the removal of confounding factors relating to socket shape.</p>","PeriodicalId":49657,"journal":{"name":"Prosthetics and Orthotics International","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prosthetics and Orthotics International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PXR.0000000000000386","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

For research in the field of prosthetics to be representative of clinical realities, studies require inclusion of clinical standard prosthetic sockets. This necessitates involvement of a prosthetist (clinical professional) in any study, which is to truly explore the effectiveness of existing or novel prosthetic technologies. Unfortunately, there is a global shortage of prosthetists. With many technological advances in upper-limb prosthetics coming from engineering focused labs, it is unsurprising that studies are frequently conducted with anatomically intact individuals. In this paper, we present a method to clone the shape of a clinical standard prosthetic socket for research purposes. The technique uses silicone to capture the socket shape; this is then converted into a plaster mold, which can be used to manufacture an identically shaped socket using standard clinical manufacturing techniques. The whole process can be achieved without the involvement of a prosthetist. To validate the proposed technique, molds from an original socket and socket clone were 3D scanned. The distance between the aligned meshes were measured using CloudCompare software. The mean distance between the points on the 2 meshes was 0.16 mm (standard deviation 0.38 mm). This proof-of-concept study demonstrates that the proposed new approach to cloning a clinical standard prosthetic socket is feasible and accurate. This technique will facilitate improvements in the assessment of prosthetic technologies. The process is nondestructive, thus also opening opportunities for socket design and electrode placement research with the removal of confounding factors relating to socket shape.

为研究目的复制临床假体套筒。
为了使假肢领域的研究能够代表临床实际情况,研究需要纳入临床标准假肢套筒。这就需要义肢修复师(临床专业人员)参与任何研究,以真正探索现有或新型义肢技术的有效性。遗憾的是,全球都存在假肢修复师短缺的问题。由于上肢假肢的许多技术进步都来自以工程学为重点的实验室,因此研究通常都是在解剖结构完整的个体身上进行,这一点不足为奇。在本文中,我们介绍了一种克隆临床标准义肢插座形状的方法,用于研究目的。该技术使用硅胶捕捉义齿槽的形状,然后将其转化为石膏模具,再利用标准临床制造技术制造出形状相同的义齿槽。整个过程无需修复师参与。为了验证所提出的技术,我们对原始义齿槽和义齿槽克隆体的模具进行了三维扫描。使用 CloudCompare 软件测量了对齐网格之间的距离。两个网格上的点之间的平均距离为 0.16 毫米(标准偏差为 0.38 毫米)。这项概念验证研究表明,所提出的克隆临床标准义齿插座的新方法是可行和准确的。这项技术将促进修复技术评估的改进。该过程是无损的,因此也为义齿槽设计和电极放置研究提供了机会,并消除了与义齿槽形状有关的干扰因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.30
自引率
13.30%
发文量
208
审稿时长
6-12 weeks
期刊介绍: Prosthetics and Orthotics International is an international, multidisciplinary journal for all professionals who have an interest in the medical, clinical, rehabilitation, technical, educational and research aspects of prosthetics, orthotics and rehabilitation engineering, as well as their related topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信