{"title":"The role of hybrid hydrogen-battery storage in a grid-connected renewable energy microgrid considering time-of-use electricity tariffs","authors":"Babangida Modu ,&nbsp;Md Pauzi Abdullah ,&nbsp;Abdulrahman AlKassem ,&nbsp;Mukhtar Fatihu Hamza ,&nbsp;Abba Lawan Bukar","doi":"10.1016/j.est.2024.114729","DOIUrl":null,"url":null,"abstract":"<div><div>Hybrid hydrogen (<span><math><msub><mi>H</mi><mn>2</mn></msub></math></span>)-battery <span><math><mfenced><mi>BT</mi></mfenced></math></span> integrated microgrid has gained significant interest lately as a key element for achieving a zero-emission future, thanks to its wide range of applications. The energy management strategy (EMS) of the <span><math><msub><mi>H</mi><mn>2</mn></msub></math></span>- <span><math><mi>BT</mi></math></span> storage-based microgrid is critical for ensuring efficient and cost-effective electricity generation by controlling the operating point of the storage systems to achieve economic and operational benefits. This paper presents an optimal energy management and sizing strategy for a hybrid <span><math><msub><mi>H</mi><mn>2</mn></msub></math></span>-<span><math><mi>BT</mi></math></span> storage-based grid-connected microgrid, considering two scenarios of Time-of-Use (ToU) electricity tariffs. The uniqueness of this study lies in its improvement of microgrid effectiveness through the optimization of component size and EMS. Among the two scenarios, the “Time of Use-Flat” scenario is more cost-effective and the best option. This conclusion is based on the results which indicate that LSC-SSA method achieved the lowest Annual System Cost (ASC) of $544,818 and the lowest Levelized Cost of Energy (LCOE) of $0.273 in this scenario. These metrics are better compared to the “Flat-Time of Use” scenario, where the LSC-SSA method achieved an ASC of $552,773 and an LCOE of $0.277. Therefore, the “Time of Use-Flat” scenario provides greater cost-effectiveness for the hybrid <span><math><msub><mi>H</mi><mn>2</mn></msub></math></span>-<span><math><mi>BT</mi></math></span> integrated microgrid.</div></div>","PeriodicalId":15942,"journal":{"name":"Journal of energy storage","volume":"105 ","pages":"Article 114729"},"PeriodicalIF":8.9000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of energy storage","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352152X24043159","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Hybrid hydrogen (H2)-battery BT integrated microgrid has gained significant interest lately as a key element for achieving a zero-emission future, thanks to its wide range of applications. The energy management strategy (EMS) of the H2- BT storage-based microgrid is critical for ensuring efficient and cost-effective electricity generation by controlling the operating point of the storage systems to achieve economic and operational benefits. This paper presents an optimal energy management and sizing strategy for a hybrid H2-BT storage-based grid-connected microgrid, considering two scenarios of Time-of-Use (ToU) electricity tariffs. The uniqueness of this study lies in its improvement of microgrid effectiveness through the optimization of component size and EMS. Among the two scenarios, the “Time of Use-Flat” scenario is more cost-effective and the best option. This conclusion is based on the results which indicate that LSC-SSA method achieved the lowest Annual System Cost (ASC) of $544,818 and the lowest Levelized Cost of Energy (LCOE) of $0.273 in this scenario. These metrics are better compared to the “Flat-Time of Use” scenario, where the LSC-SSA method achieved an ASC of $552,773 and an LCOE of $0.277. Therefore, the “Time of Use-Flat” scenario provides greater cost-effectiveness for the hybrid H2-BT integrated microgrid.
考虑到分时电价,氢电池混合储能在并网可再生能源微电网中的作用
氢气(H2)-电池 BT 混合集成微电网作为实现零排放未来的关键因素,因其广泛的应用范围而受到广泛关注。氢电池混合微电网的能源管理策略(EMS)对于通过控制储能系统的工作点来实现经济和运营效益,从而确保高效、经济地发电至关重要。本文提出了基于 H2-BT 储能技术的混合并网微电网的最佳能源管理和规模策略,并考虑了两种使用时间(ToU)电价方案。本研究的独特之处在于通过优化组件尺寸和 EMS 提高了微电网的效率。在两种方案中,"使用时间-平价 "方案更具成本效益,是最佳选择。这一结论基于以下结果:LSC-SSA 方法在该方案中实现了最低的年系统成本(ASC)544,818 美元和最低的平准化能源成本(LCOE)0.273 美元。这些指标均优于 "统一使用时间 "方案,在 "统一使用时间 "方案中,LSC-SSA 方法的 ASC 为 552,773 美元,LCOE 为 0.277 美元。因此,"使用时间-持平 "方案为 H2-BT 混合集成微电网提供了更高的成本效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of energy storage
Journal of energy storage Energy-Renewable Energy, Sustainability and the Environment
CiteScore
11.80
自引率
24.50%
发文量
2262
审稿时长
69 days
期刊介绍: Journal of energy storage focusses on all aspects of energy storage, in particular systems integration, electric grid integration, modelling and analysis, novel energy storage technologies, sizing and management strategies, business models for operation of storage systems and energy storage developments worldwide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信