Spatiotemporal Variance Image Reconstruction for Thermographic Inspections

Logan M. Wilcox;Emily M. Johnson;Emma T. Bohannon;Catherine E. Johnson;Kristen M. Donnell
{"title":"Spatiotemporal Variance Image Reconstruction for Thermographic Inspections","authors":"Logan M. Wilcox;Emily M. Johnson;Emma T. Bohannon;Catherine E. Johnson;Kristen M. Donnell","doi":"10.1109/OJIM.2024.3493891","DOIUrl":null,"url":null,"abstract":"Active microwave thermography (AMT) is a nondestructive testing and evaluation (NDT&E) technique that utilizes a radiating antenna to induce a thermal increase on or within a specimen under test (SUT). The radiated power density is spatially nonuniform and therefore results in a spatially nonuniform thermal excitation, which may result in missed or false indications of defects. To this end, this work proposes a novel image reconstruction technique for nonuniform excitation/heating and is referred to as spatiotemporal variance reconstruction (STVR). STVR utilizes the spatial and temporal variance of the surface thermal profile. STVR is advantageous in that it does not require a reference measurement nor manipulation of the interrogating signal to mitigate the effect of the nonuniform thermal excitation. To illustrate the improvements offered by STVR, AMT measurements were completed on a set of carbon fiber-reinforced polymer (CFRP) structures with an absorbing topcoat. Additional thermographic measurements were completed utilizing a halogen lamp source on a pressed high explosive (HE) SUT. In all cases, the STVR-processed results provide an indication of the defect, within 5% spatial error, without the need for a reference measurement or signal manipulation, which was not previously possible.","PeriodicalId":100630,"journal":{"name":"IEEE Open Journal of Instrumentation and Measurement","volume":"3 ","pages":"1-11"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10747210","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Instrumentation and Measurement","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10747210/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Active microwave thermography (AMT) is a nondestructive testing and evaluation (NDT&E) technique that utilizes a radiating antenna to induce a thermal increase on or within a specimen under test (SUT). The radiated power density is spatially nonuniform and therefore results in a spatially nonuniform thermal excitation, which may result in missed or false indications of defects. To this end, this work proposes a novel image reconstruction technique for nonuniform excitation/heating and is referred to as spatiotemporal variance reconstruction (STVR). STVR utilizes the spatial and temporal variance of the surface thermal profile. STVR is advantageous in that it does not require a reference measurement nor manipulation of the interrogating signal to mitigate the effect of the nonuniform thermal excitation. To illustrate the improvements offered by STVR, AMT measurements were completed on a set of carbon fiber-reinforced polymer (CFRP) structures with an absorbing topcoat. Additional thermographic measurements were completed utilizing a halogen lamp source on a pressed high explosive (HE) SUT. In all cases, the STVR-processed results provide an indication of the defect, within 5% spatial error, without the need for a reference measurement or signal manipulation, which was not previously possible.
用于热成像检测的时空方差图像重构
有源微波热成像仪(AMT)是一种无损检测和评估(NDT&E)技术,它利用辐射天线在被测样品(SUT)上或被测样品内部引起热量增加。辐射功率密度在空间上是不均匀的,因此会产生空间上不均匀的热激励,这可能会导致漏报或误报缺陷。为此,本研究提出了一种针对非均匀激励/加热的新型图像重建技术,即时空方差重建(STVR)。STVR 利用表面热剖面的时空方差。STVR 的优势在于,它不需要参考测量,也不需要对询问信号进行处理来减轻非均匀热激励的影响。为了说明 STVR 所带来的改进,我们在一组带有吸收表层的碳纤维增强聚合物 (CFRP) 结构上完成了 AMT 测量。此外,还利用卤素灯源对压制的高爆 (HE) SUT 进行了热成像测量。在所有情况下,经过 STVR 处理的结果都能显示缺陷,空间误差不超过 5%,而且无需参考测量或信号处理,这在以前是不可能实现的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信