Chunfei Zhong , Xinyan Li , Fan Zhang , Ning Liu , Jiewei Deng , Yunyun Yang , Tiangang Luan
{"title":"Rapid and sensitive determination of bongkrekic acid with molecularly imprinted polymer-coated wooden-tip electrospray ionization mass spectrometry","authors":"Chunfei Zhong , Xinyan Li , Fan Zhang , Ning Liu , Jiewei Deng , Yunyun Yang , Tiangang Luan","doi":"10.1016/j.sampre.2024.100137","DOIUrl":null,"url":null,"abstract":"<div><div>In this study, a novel methodology has been developed for the rapid and sensitive analysis of bongkrekic acid (BA), a highly toxic bacterial metabolite, using a molecularly imprinted polymer-coated wooden-tip coupled with electrospray ionization mass spectrometry (MIPWT-ESI-MS). A MIPWT solid phase microextraction (SPME) probe specifically tailored for BA was fabricated, by employing dummy template molecules/functional monomers in the imprinting coating modification. This approach exhibits an enrichment factor (EF) of 683 ± 53 for efficient extraction of BA from aqueous matrices, demonstrating the utility of dummy templates in enhancing the selectivity and sensitivity of the MIPWT-ESI-MS method. The analytical performance of the MIPWT-ESI-MS method was evaluated, demonstrating a desirable linear correlation (<em>r</em> = 0.9988), along with remarkable sensitivity by a limit of detection (LOD) and limit of quantitation (LOQ) at 0.05 μg/L and 0.16 μg/L in pure water, respectively. Additionally, the method demonstrated high repeatability with a relative standard deviation (RSD) < 3.9 % (<em>n</em> = 6) and reproducibility with an RSD < 13.4 %. The practical application of the method was confirmed through the successful analysis of real-world samples, including tap water, wastewater from a food processing factory, and the aqueous extracts of food samples, with BA detected at 0.296 µg/L in <em>Tremella</em>. Spiking experiments further validated the accuracy of the method, with recoveries ranging from 81 % to 97 %. This study integrates MIP with ambient mass spectrometry, offering a robust, selective, and sensitive tool for the monitoring of trace BA levels in complex food and environmental samples, contributing significantly to public health safety and food quality control.</div></div>","PeriodicalId":100052,"journal":{"name":"Advances in Sample Preparation","volume":"12 ","pages":"Article 100137"},"PeriodicalIF":5.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Sample Preparation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772582024000354","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
In this study, a novel methodology has been developed for the rapid and sensitive analysis of bongkrekic acid (BA), a highly toxic bacterial metabolite, using a molecularly imprinted polymer-coated wooden-tip coupled with electrospray ionization mass spectrometry (MIPWT-ESI-MS). A MIPWT solid phase microextraction (SPME) probe specifically tailored for BA was fabricated, by employing dummy template molecules/functional monomers in the imprinting coating modification. This approach exhibits an enrichment factor (EF) of 683 ± 53 for efficient extraction of BA from aqueous matrices, demonstrating the utility of dummy templates in enhancing the selectivity and sensitivity of the MIPWT-ESI-MS method. The analytical performance of the MIPWT-ESI-MS method was evaluated, demonstrating a desirable linear correlation (r = 0.9988), along with remarkable sensitivity by a limit of detection (LOD) and limit of quantitation (LOQ) at 0.05 μg/L and 0.16 μg/L in pure water, respectively. Additionally, the method demonstrated high repeatability with a relative standard deviation (RSD) < 3.9 % (n = 6) and reproducibility with an RSD < 13.4 %. The practical application of the method was confirmed through the successful analysis of real-world samples, including tap water, wastewater from a food processing factory, and the aqueous extracts of food samples, with BA detected at 0.296 µg/L in Tremella. Spiking experiments further validated the accuracy of the method, with recoveries ranging from 81 % to 97 %. This study integrates MIP with ambient mass spectrometry, offering a robust, selective, and sensitive tool for the monitoring of trace BA levels in complex food and environmental samples, contributing significantly to public health safety and food quality control.