Muhammad Taha Hagar, Christopher L Schlett, Tim Oechsner, Akos Varga-Szemes, Tilman Emrich, Xiao Yan Chen, Dmitrij Kravchenko, Giuseppe Tremamunno, Milán Vecsey-Nagy, Moises Felipe Molina-Fuentes, Tobias Krauss, Jana Taron, Christopher Schuppert, Fabian Bamberg, Martin Soschynski
{"title":"Photon-Counting Detector CT: Advances and Clinical Applications in Cardiovascular Imaging.","authors":"Muhammad Taha Hagar, Christopher L Schlett, Tim Oechsner, Akos Varga-Szemes, Tilman Emrich, Xiao Yan Chen, Dmitrij Kravchenko, Giuseppe Tremamunno, Milán Vecsey-Nagy, Moises Felipe Molina-Fuentes, Tobias Krauss, Jana Taron, Christopher Schuppert, Fabian Bamberg, Martin Soschynski","doi":"10.1055/a-2452-0288","DOIUrl":null,"url":null,"abstract":"<p><p>Since the approval of the first dual-source photon-counting detector CT (PCD-CT) in the fall of 2021, significant insights have been gained in its application for cardiovascular imaging. This review aims to provide a comprehensive overview of the current state of knowledge and the growing body of research literature, illustrating innovative applications and perspectives through case examples.We conducted a structured literature review, identifying relevant studies via Google Scholar and PubMed, using the keywords \"photon-counting detector\", \"cardiovascular CT\", \"cardiac CT\", and \"ultra-high-resolution CT\". We analyzed studies published since January 2015. Additionally, we integrated our own clinical experiences and case examples.In addition to the well-known benefit of increased temporal resolution offered by dual-source scanners, dual-source PCD-CT provides three key advantages: 1) Optimized geometric dose efficiency with an improved contrast-to-noise ratio, 2) intrinsic spectral sensitivity, and 3) the ability for ultrahigh-resolution CT. This technology enables improved image quality or radiation dose reduction in established cardiovascular protocols. Its use in non-invasive cardiac diagnostics for obese patients, those with a high plaque burden, or after stent implantation appears technically feasible, potentially expanding the scope of CT. The spectral sensitivity also allows tailored image acquisition, reducing metallic artifacts and contrast agent doses in patients with renal impairment. Early studies and clinical experience support these potential applications of PCD-CT in cardiovascular diagnostics, suggesting workflow optimization and improved patient management.However, challenges remain, including high costs, large data volumes, somewhat longer reconstruction times, and technical difficulties in combining spectral sensitivity with ultra-high resolution. Prospective randomized studies with clinical endpoints are lacking to confirm the clear advantage over conventional scanners. Future research should focus on endpoint-based studies and robust cost-benefit analyses to evaluate the potential of this technology and facilitate its evidence-based integration in clinical practice. · Photon-counting detector CT represents a technological advancement in computed tomography.. · Spectral sensitivity enhances iodine signal and minimizes artifacts.. · Ultra-high-resolution CT allows precise imaging, even in stents and advanced sclerosis.. · This technology must be validated through endpoint-based, randomized studies.. · Hagar MT, Schlett CL, Oechsner T et al. Photon-Counting Detector CT: Advances and Clinical Applications in Cardiovascular Imaging. Fortschr Röntgenstr 2024; DOI 10.1055/a-2452-0288.</p>","PeriodicalId":21490,"journal":{"name":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2452-0288","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Since the approval of the first dual-source photon-counting detector CT (PCD-CT) in the fall of 2021, significant insights have been gained in its application for cardiovascular imaging. This review aims to provide a comprehensive overview of the current state of knowledge and the growing body of research literature, illustrating innovative applications and perspectives through case examples.We conducted a structured literature review, identifying relevant studies via Google Scholar and PubMed, using the keywords "photon-counting detector", "cardiovascular CT", "cardiac CT", and "ultra-high-resolution CT". We analyzed studies published since January 2015. Additionally, we integrated our own clinical experiences and case examples.In addition to the well-known benefit of increased temporal resolution offered by dual-source scanners, dual-source PCD-CT provides three key advantages: 1) Optimized geometric dose efficiency with an improved contrast-to-noise ratio, 2) intrinsic spectral sensitivity, and 3) the ability for ultrahigh-resolution CT. This technology enables improved image quality or radiation dose reduction in established cardiovascular protocols. Its use in non-invasive cardiac diagnostics for obese patients, those with a high plaque burden, or after stent implantation appears technically feasible, potentially expanding the scope of CT. The spectral sensitivity also allows tailored image acquisition, reducing metallic artifacts and contrast agent doses in patients with renal impairment. Early studies and clinical experience support these potential applications of PCD-CT in cardiovascular diagnostics, suggesting workflow optimization and improved patient management.However, challenges remain, including high costs, large data volumes, somewhat longer reconstruction times, and technical difficulties in combining spectral sensitivity with ultra-high resolution. Prospective randomized studies with clinical endpoints are lacking to confirm the clear advantage over conventional scanners. Future research should focus on endpoint-based studies and robust cost-benefit analyses to evaluate the potential of this technology and facilitate its evidence-based integration in clinical practice. · Photon-counting detector CT represents a technological advancement in computed tomography.. · Spectral sensitivity enhances iodine signal and minimizes artifacts.. · Ultra-high-resolution CT allows precise imaging, even in stents and advanced sclerosis.. · This technology must be validated through endpoint-based, randomized studies.. · Hagar MT, Schlett CL, Oechsner T et al. Photon-Counting Detector CT: Advances and Clinical Applications in Cardiovascular Imaging. Fortschr Röntgenstr 2024; DOI 10.1055/a-2452-0288.
期刊介绍:
Die RöFo veröffentlicht Originalarbeiten, Übersichtsartikel und Fallberichte aus dem Bereich der Radiologie und den weiteren bildgebenden Verfahren in der Medizin. Es dürfen nur Arbeiten eingereicht werden, die noch nicht veröffentlicht sind und die auch nicht gleichzeitig einer anderen Zeitschrift zur Veröffentlichung angeboten wurden. Alle eingereichten Beiträge unterliegen einer sorgfältigen fachlichen Begutachtung.
Gegründet 1896 – nur knapp 1 Jahr nach der Entdeckung der Röntgenstrahlen durch C.W. Röntgen – blickt die RöFo auf über 100 Jahre Erfahrung als wichtigstes Publikationsmedium in der deutschsprachigen Radiologie zurück. Sie ist damit die älteste radiologische Fachzeitschrift und schafft es erfolgreich, lange Kontinuität mit dem Anspruch an wissenschaftliches Publizieren auf internationalem Niveau zu verbinden. Durch ihren zentralen Platz im Verlagsprogramm stellte die RöFo die Basis für das heute umfassende und erfolgreiche Radiologie-Medienangebot im Georg Thieme Verlag.
Besonders eng verbunden ist die RöFo mit der Geschichte der Röntgengesellschaften in Deutschland und Österreich. Sie ist offizielles Organ von DRG und ÖRG und die Mitglieder der Fachgesellschaften erhalten die Zeitschrift im Rahmen ihrer Mitgliedschaft. Mit ihrem wissenschaftlichen Kernteil und dem eigenen Mitteilungsteil der Fachgesellschaften bietet die RöFo Monat für Monat ein Forum für den Austausch von Inhalten und Botschaften der radiologischen Community im deutschsprachigen Raum.