Daohong Wei , Mengwei He , Jingjing Zhang , Dong Liu , Md. Apel Mahmud
{"title":"Enhancing the economic efficiency of wind-photovoltaic‑hydrogen complementary power systems via optimizing capacity allocation","authors":"Daohong Wei , Mengwei He , Jingjing Zhang , Dong Liu , Md. Apel Mahmud","doi":"10.1016/j.est.2024.114531","DOIUrl":null,"url":null,"abstract":"<div><div>Renewable energy generation has emerged as an important strategy in achieving dual carbon. However, the inherent randomness and uncontrollability of major new energy resources present significant challenges for the safe and stable operation of power system. Advanced energy storage technologies are essential to enhance the stability of grid-connected power system incorporating wind and solar energy resources. Reasonable allocation of wind power, photovoltaic (PV), and energy storage capacity is the key to ensuring the economy and reliability of power system. To achieve this goal, a mathematical model of the wind-photovoltaic‑hydrogen complementary power system (WPHCPS) is established to achieve economical and reliable system operation. A control algorithm based on the composite grey wolf optimization (GWO) and particle swarm optimization (PSO) is proposed for the maximum power point tracking (MPPT) of PV system as well as capacity allocation of WPHCPS. Finally, a case demonstrating the optimal capacity configuration scheme is quantitatively analyzed, where the load shortage rate and abandonment rate of wind and solar power are considered. The quantified results show that the optimal operating scene is 50 wind turbines, 2521 PV arrays, 25 batteries, 30 electrolytic cells, 38 hydrogen storage tanks, and 54 hydrogen fuel cells, with the total revenue 232,895.9 CNY. The wind and solar abandonment rate and load interruption rate are 0.36 % and 0.21 %, respectively. The methods and results obtained provide a reference for improving the consumption and stability of the complementary power system and achieving sustainable utilization of clean energy.</div></div>","PeriodicalId":15942,"journal":{"name":"Journal of energy storage","volume":"104 ","pages":"Article 114531"},"PeriodicalIF":8.9000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of energy storage","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352152X24041173","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
Renewable energy generation has emerged as an important strategy in achieving dual carbon. However, the inherent randomness and uncontrollability of major new energy resources present significant challenges for the safe and stable operation of power system. Advanced energy storage technologies are essential to enhance the stability of grid-connected power system incorporating wind and solar energy resources. Reasonable allocation of wind power, photovoltaic (PV), and energy storage capacity is the key to ensuring the economy and reliability of power system. To achieve this goal, a mathematical model of the wind-photovoltaic‑hydrogen complementary power system (WPHCPS) is established to achieve economical and reliable system operation. A control algorithm based on the composite grey wolf optimization (GWO) and particle swarm optimization (PSO) is proposed for the maximum power point tracking (MPPT) of PV system as well as capacity allocation of WPHCPS. Finally, a case demonstrating the optimal capacity configuration scheme is quantitatively analyzed, where the load shortage rate and abandonment rate of wind and solar power are considered. The quantified results show that the optimal operating scene is 50 wind turbines, 2521 PV arrays, 25 batteries, 30 electrolytic cells, 38 hydrogen storage tanks, and 54 hydrogen fuel cells, with the total revenue 232,895.9 CNY. The wind and solar abandonment rate and load interruption rate are 0.36 % and 0.21 %, respectively. The methods and results obtained provide a reference for improving the consumption and stability of the complementary power system and achieving sustainable utilization of clean energy.
期刊介绍:
Journal of energy storage focusses on all aspects of energy storage, in particular systems integration, electric grid integration, modelling and analysis, novel energy storage technologies, sizing and management strategies, business models for operation of storage systems and energy storage developments worldwide.