Experimental study on flow boiling and circumferential non-uniform heat transfer characteristics in helically-coiled tube under coupled heat transfer conditions

IF 6.1 2区 工程技术 Q2 ENERGY & FUELS
Hengyuan Wang, Qiyu Xuan, Hailin Lei, Xi Li, Zhibin Li, Huixiong Li
{"title":"Experimental study on flow boiling and circumferential non-uniform heat transfer characteristics in helically-coiled tube under coupled heat transfer conditions","authors":"Hengyuan Wang,&nbsp;Qiyu Xuan,&nbsp;Hailin Lei,&nbsp;Xi Li,&nbsp;Zhibin Li,&nbsp;Huixiong Li","doi":"10.1016/j.applthermaleng.2024.124844","DOIUrl":null,"url":null,"abstract":"<div><div>Helically-coiled tube steam generator has been widely used in nuclear reactor, energy power, petrochemical and other systems. In the liquid metal reactor, the liquid metal on the primary side of the helically-coiled tube steam generator exchanges heat with the water on the secondary side. Due to the coupled heat transfer between liquid metal and water, the distribution of the wall temperature or heat transfer coefficient of helically-coiled tube are significant different in the circumferential direction of the tube cross-section. An experimental system of helically-coiled tube steam generator was set up in this paper. The non-uniform heat transfer characteristics of secondary side fluid of helically-coiled tube steam generator were studied under the coupled heat transfer conditions between the heat transfer of primary side and secondary sides fluid. It was found that the wall temperature or heat transfer coefficient in the circumferential direction of tube cross-section were significantly different, the maximum and minimum wall temperature appeared on the inside and bottom of the tube cross-section, respectively, the maximum and minimum heat transfer coefficient appeared on the outside and top of the tube cross-section, respectively. The effect of secondary side refrigerant pressure, secondary side refrigerant supercooling degree, mass flux of secondary side refrigerant, primary side heating water temperature and mass flux of primary side heating water on the maximum wall temperature, minimum wall temperature, maximum heat transfer coefficient, minimum heat transfer coefficient were obtained. Beside, The local and overall non-uniformity of the wall temperature and heat transfer coefficient in the circumferential direction of tube cross-section were obtained and the influence of each parameter on the local and overall non-uniformity were revealed, respectively. Finally, it was concluded that the non-uniformity of heat transfer coefficient in the circumferential direction of tube cross-section under coupled heat transfer conditions was more obvious than that under constant heat flux conditions. And the the overall non-uniformity of heat transfer coefficient (δ<sub>h</sub>) obtained in our experimental were larger than the δ<sub>h</sub> of Chang et al. <span><span>[33]</span></span>, Zheng et al. <span><span>[38]</span></span>, Kong et al. <span><span>[34]</span></span>, Yao et al. <span><span>[36]</span></span> and Niu et al. <span><span>[37]</span></span> by 130.67%, 48.10%, 289.48%, 151.28% and 271.67%, respectively.</div></div>","PeriodicalId":8201,"journal":{"name":"Applied Thermal Engineering","volume":"258 ","pages":"Article 124844"},"PeriodicalIF":6.1000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Thermal Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1359431124025122","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Helically-coiled tube steam generator has been widely used in nuclear reactor, energy power, petrochemical and other systems. In the liquid metal reactor, the liquid metal on the primary side of the helically-coiled tube steam generator exchanges heat with the water on the secondary side. Due to the coupled heat transfer between liquid metal and water, the distribution of the wall temperature or heat transfer coefficient of helically-coiled tube are significant different in the circumferential direction of the tube cross-section. An experimental system of helically-coiled tube steam generator was set up in this paper. The non-uniform heat transfer characteristics of secondary side fluid of helically-coiled tube steam generator were studied under the coupled heat transfer conditions between the heat transfer of primary side and secondary sides fluid. It was found that the wall temperature or heat transfer coefficient in the circumferential direction of tube cross-section were significantly different, the maximum and minimum wall temperature appeared on the inside and bottom of the tube cross-section, respectively, the maximum and minimum heat transfer coefficient appeared on the outside and top of the tube cross-section, respectively. The effect of secondary side refrigerant pressure, secondary side refrigerant supercooling degree, mass flux of secondary side refrigerant, primary side heating water temperature and mass flux of primary side heating water on the maximum wall temperature, minimum wall temperature, maximum heat transfer coefficient, minimum heat transfer coefficient were obtained. Beside, The local and overall non-uniformity of the wall temperature and heat transfer coefficient in the circumferential direction of tube cross-section were obtained and the influence of each parameter on the local and overall non-uniformity were revealed, respectively. Finally, it was concluded that the non-uniformity of heat transfer coefficient in the circumferential direction of tube cross-section under coupled heat transfer conditions was more obvious than that under constant heat flux conditions. And the the overall non-uniformity of heat transfer coefficient (δh) obtained in our experimental were larger than the δh of Chang et al. [33], Zheng et al. [38], Kong et al. [34], Yao et al. [36] and Niu et al. [37] by 130.67%, 48.10%, 289.48%, 151.28% and 271.67%, respectively.
耦合传热条件下螺旋线圈管内流动沸腾和圆周非均匀传热特性的实验研究
螺旋卷管蒸汽发生器已广泛应用于核反应堆、能源动力、石油化工等系统。在液态金属反应堆中,螺旋卷管蒸汽发生器一次侧的液态金属与二次侧的水进行热交换。由于液态金属和水之间的耦合传热,螺旋卷管壁温或传热系数的分布在管横截面的圆周方向上存在显著差异。本文建立了一个螺旋卷管蒸汽发生器实验系统。在一次侧和二次侧流体传热耦合条件下,研究了螺旋盘管蒸汽发生器二次侧流体的非均匀传热特性。研究发现,管横截面圆周方向的壁温或传热系数存在显著差异,最大和最小壁温分别出现在管横截面的内侧和底部,最大和最小传热系数分别出现在管横截面的外侧和顶部。得出了二次侧制冷剂压力、二次侧制冷剂过冷度、二次侧制冷剂质量通量、一次侧加热水温度和一次侧加热水质量通量对最高壁温、最低壁温、最大传热系数和最小传热系数的影响。此外,还得到了管壁温度和传热系数在管横截面圆周方向上的局部不均匀性和整体不均匀性,并分别揭示了各参数对局部不均匀性和整体不均匀性的影响。最后得出结论:在耦合传热条件下,管横截面圆周方向传热系数的不均匀性比恒定热通量条件下更为明显。而我们实验得到的传热系数总体不均匀度(δh)分别比 Chang 等[33]、Zheng 等[38]、Kong 等[34]、Yao 等[36]和 Niu 等[37]的δh 大 130.67%、48.10%、289.48%、151.28% 和 271.67%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Thermal Engineering
Applied Thermal Engineering 工程技术-工程:机械
CiteScore
11.30
自引率
15.60%
发文量
1474
审稿时长
57 days
期刊介绍: Applied Thermal Engineering disseminates novel research related to the design, development and demonstration of components, devices, equipment, technologies and systems involving thermal processes for the production, storage, utilization and conservation of energy, with a focus on engineering application. The journal publishes high-quality and high-impact Original Research Articles, Review Articles, Short Communications and Letters to the Editor on cutting-edge innovations in research, and recent advances or issues of interest to the thermal engineering community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信