ECG Features in Orthotopic Cardiac Xenotransplantation: Comparisons With Published Literature.

IF 3.3 4区 医学 Q2 MEDICINE, RESEARCH & EXPERIMENTAL
Chace B Mitchell, Joe Simmons, Sarah J Neal, David C Cleveland, Yaniv Bar-Cohen, John D Cleveland
{"title":"ECG Features in Orthotopic Cardiac Xenotransplantation: Comparisons With Published Literature.","authors":"Chace B Mitchell, Joe Simmons, Sarah J Neal, David C Cleveland, Yaniv Bar-Cohen, John D Cleveland","doi":"10.1111/xen.70005","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Although there is a plethora of literature on electrocardiographic changes following cardiac allotransplantation, there is little in the field of cardiac xenotransplantation. The only published literature to date is that of the first pig-to-human cardiac xenotransplantation. Here we take a close look at the electrocardiographic parameters in four non-human primate recipients of orthotopic cardiac xenotransplantation to develop baseline metrics for comparison.</p><p><strong>Methods: </strong>Orthotopic cardiac xenotransplantion was carried out in four non-human primate recipients. Electrocardiographic parameters were followed at various intervals using an internal hemodynamic monitoring system (DSI) as well as a standard 12-lead electrocardiogram (ECG). ECG intervals were then compared to published literature on porcine ECG intervals and pig-to-human cardiac xenotransplantation.</p><p><strong>Results: </strong>There were no significant differences observed between timepoints for HR, PR, QRS, QT, or QTc after cardiac xenotransplantation for each animal subject. ECG parameters were statistically similar to those of in situ mini-pig hearts in the literature. ECG parameters from the DSI on average were shorter than those from a traditional ECG, however, DSI parameters were consistent over time.</p><p><strong>Conclusion: </strong>These results demonstrate the possibility of conduction health for genetically engineered porcine donor hearts following cardiac xenotransplantation. Ongoing work to compare the results of an ECG in a porcine donor heart before and after implantation into a NHP is necessary to better characterize variables that may be at play in the function of the conduction system.</p>","PeriodicalId":23866,"journal":{"name":"Xenotransplantation","volume":"31 6","pages":"e70005"},"PeriodicalIF":3.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Xenotransplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/xen.70005","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Although there is a plethora of literature on electrocardiographic changes following cardiac allotransplantation, there is little in the field of cardiac xenotransplantation. The only published literature to date is that of the first pig-to-human cardiac xenotransplantation. Here we take a close look at the electrocardiographic parameters in four non-human primate recipients of orthotopic cardiac xenotransplantation to develop baseline metrics for comparison.

Methods: Orthotopic cardiac xenotransplantion was carried out in four non-human primate recipients. Electrocardiographic parameters were followed at various intervals using an internal hemodynamic monitoring system (DSI) as well as a standard 12-lead electrocardiogram (ECG). ECG intervals were then compared to published literature on porcine ECG intervals and pig-to-human cardiac xenotransplantation.

Results: There were no significant differences observed between timepoints for HR, PR, QRS, QT, or QTc after cardiac xenotransplantation for each animal subject. ECG parameters were statistically similar to those of in situ mini-pig hearts in the literature. ECG parameters from the DSI on average were shorter than those from a traditional ECG, however, DSI parameters were consistent over time.

Conclusion: These results demonstrate the possibility of conduction health for genetically engineered porcine donor hearts following cardiac xenotransplantation. Ongoing work to compare the results of an ECG in a porcine donor heart before and after implantation into a NHP is necessary to better characterize variables that may be at play in the function of the conduction system.

异位心脏移植中的心电图特征:与已发表文献的比较。
导言:尽管有关心脏同种异体移植后心电图变化的文献很多,但在心脏异种移植领域的文献却很少。迄今为止,唯一发表的文献是第一例猪-人心脏异种移植。在此,我们仔细研究了四种非人灵长类动物心脏异种移植受体的心电图参数,以制定用于比较的基线指标:方法:对四名非人灵长类受体进行心脏异种移植。使用内部血液动力学监测系统(DSI)和标准 12 导联心电图(ECG)在不同时间间隔跟踪心电图参数。然后将心电图间隔与已发表的猪心电图间隔和猪对人心脏异种移植文献进行比较:结果:每个动物实验对象在心脏异种移植后的HR、PR、QRS、QT或QTc时点之间均无明显差异。心电图参数在统计学上与文献中原位微型猪心的参数相似。DSI的心电图参数平均比传统心电图参数短,但DSI参数随时间变化保持一致:这些结果表明,在心脏异种移植后,基因工程猪供体心脏的传导健康是可能的。为了更好地描述可能影响传导系统功能的变量,有必要对猪供体心脏植入NHP前后的心电图结果进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Xenotransplantation
Xenotransplantation 医学-医学:研究与实验
CiteScore
6.80
自引率
15.40%
发文量
58
审稿时长
>12 weeks
期刊介绍: Xenotransplantation provides its readership with rapid communication of new findings in the field of organ and tissue transplantation across species barriers.The journal is not only of interest to those whose primary area is xenotransplantation, but also to veterinarians, microbiologists and geneticists. It also investigates and reports on the controversial theological, ethical, legal and psychological implications of xenotransplantation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信