“Best” Iterative Coupled-Cluster Triples Model? More Evidence for 3CC

IF 2.7 2区 化学 Q3 CHEMISTRY, PHYSICAL
Nakul K. Teke, Ajay Melekamburath, Bimal Gaudel and Edward F. Valeev*, 
{"title":"“Best” Iterative Coupled-Cluster Triples Model? More Evidence for 3CC","authors":"Nakul K. Teke,&nbsp;Ajay Melekamburath,&nbsp;Bimal Gaudel and Edward F. Valeev*,&nbsp;","doi":"10.1021/acs.jpca.4c0466710.1021/acs.jpca.4c04667","DOIUrl":null,"url":null,"abstract":"<p >To follow up on the unexpectedly good performance of several coupled-cluster models with approximate inclusion of 3-body clusters [<contrib-group><span>Rishi, V.</span>; <span>Valeev, E. F.</span></contrib-group> <cite><i>J. Chem. Phys.</i></cite> <span>2019</span>, <em>151</em>, <elocation-id>064102</elocation-id>.] we performed a more complete assessment of the 3CC method [<contrib-group><span>Feller, D.</span></contrib-group> . <cite><i>J. Chem. Phys.</i></cite> <span>2008</span>, <em>129</em>, <elocation-id>204105</elocation-id>.] for accurate computational thermochemistry in the standard HEAT framework. New spin-integrated implementation of the 3CC method applicable to closed- and open-shell systems utilizes a new automated toolchain for derivation, optimization, and evaluation of operator algebra in many-body electronic structure. We found that with a double-ζ basis set the 3CC correlation energies and their atomization energy contributions are almost always more accurate (with respect to the CCSDTQ reference) than the CCSDT model as well as the standard CCSD(T) model. The mean absolute errors in cc-pVDZ {3CC, CCSDT, and CCSD(T)} electronic (per valence electron) and atomization energies relative to the CCSDTQ reference for the HEAT data set [<contrib-group><span>Tajti, A.</span></contrib-group> . <cite><i>J. Chem. Phys.</i></cite> <span>2004</span>, <em>121</em>, 11599–11613.], were {24, 70, 122} μ<i>E</i><sub>h</sub>/<i>e</i> and {0.46, 2.00, 2.58} kJ/mol, respectively. The mean absolute errors in the complete-basis-set limit {3CC, CCSDT, and CCSD(T)} atomization energies relative to the HEAT model reference, were {0.52, 2.00, and 1.07} kJ/mol, The significant and systematic reduction of the error by the 3CC method and its lower cost than CCSDT suggests it as a viable candidate for post-CCSD(T) thermochemistry applications, as well as the preferred alternative to CCSDT in general.</p>","PeriodicalId":59,"journal":{"name":"The Journal of Physical Chemistry A","volume":"128 45","pages":"9819–9828 9819–9828"},"PeriodicalIF":2.7000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acs.jpca.4c04667","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Physical Chemistry A","FirstCategoryId":"1","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acs.jpca.4c04667","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

To follow up on the unexpectedly good performance of several coupled-cluster models with approximate inclusion of 3-body clusters [Rishi, V.; Valeev, E. F. J. Chem. Phys. 2019, 151, 064102.] we performed a more complete assessment of the 3CC method [Feller, D. . J. Chem. Phys. 2008, 129, 204105.] for accurate computational thermochemistry in the standard HEAT framework. New spin-integrated implementation of the 3CC method applicable to closed- and open-shell systems utilizes a new automated toolchain for derivation, optimization, and evaluation of operator algebra in many-body electronic structure. We found that with a double-ζ basis set the 3CC correlation energies and their atomization energy contributions are almost always more accurate (with respect to the CCSDTQ reference) than the CCSDT model as well as the standard CCSD(T) model. The mean absolute errors in cc-pVDZ {3CC, CCSDT, and CCSD(T)} electronic (per valence electron) and atomization energies relative to the CCSDTQ reference for the HEAT data set [Tajti, A. . J. Chem. Phys. 2004, 121, 11599–11613.], were {24, 70, 122} μEh/e and {0.46, 2.00, 2.58} kJ/mol, respectively. The mean absolute errors in the complete-basis-set limit {3CC, CCSDT, and CCSD(T)} atomization energies relative to the HEAT model reference, were {0.52, 2.00, and 1.07} kJ/mol, The significant and systematic reduction of the error by the 3CC method and its lower cost than CCSDT suggests it as a viable candidate for post-CCSD(T) thermochemistry applications, as well as the preferred alternative to CCSDT in general.

"最佳 "迭代耦合-集群三重模型?3CC 的更多证据
为了跟进几个近似包含三体簇的耦合簇模型[Rishi, V.; Valeev, E. F. J. Chem. Phys. 2019, 151, 064102.] 出人意料的良好性能,我们对 3CC 方法[Feller, D. . J. Chem. Phys. 2008, 129, 204105.] 进行了更全面的评估,以便在标准 HEAT 框架内精确计算热化学。适用于闭壳和开壳系统的 3CC 方法的新自旋集成实施,利用新的自动化工具链来推导、优化和评估多体电子结构中的算子代数。我们发现,与 CCSDT 模型和标准 CCSD(T) 模型相比,使用双ζ基集的 3CC 相关能及其雾化能贡献几乎总是更精确(相对于 CCSDTQ 参考)。对于 HEAT 数据集[Tajti, A. . J. Chem. Phys. 2004, 121, 11599-11613.],cc-pVDZ{3CC、CCSDT 和 CCSD(T)} 电子(每个价电子)和雾化能相对于 CCSDTQ 参考的平均绝对误差分别为{24, 70, 122} μEh/e 和 {0.46, 2.00, 2.58} kJ/mol。3CC方法显著而系统地减少了误差,而且成本低于CCSDT,这表明它是后CCSD(T)热化学应用的可行候选方法,也是CCSDT的首选替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
The Journal of Physical Chemistry A
The Journal of Physical Chemistry A 化学-物理:原子、分子和化学物理
CiteScore
5.20
自引率
10.30%
发文量
922
审稿时长
1.3 months
期刊介绍: The Journal of Physical Chemistry A is devoted to reporting new and original experimental and theoretical basic research of interest to physical chemists, biophysical chemists, and chemical physicists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信