Analytical exploration of wave theory based highly sensitive fiber optic bio-sensor irradiated by BG beam for early diagnosis of dengue infection

IF 2 3区 物理与天体物理 Q3 OPTICS
Bijaya Saha, Nabamita Goswami, Ardhendu Saha, Krishna Kanta Kakati
{"title":"Analytical exploration of wave theory based highly sensitive fiber optic bio-sensor irradiated by BG beam for early diagnosis of dengue infection","authors":"Bijaya Saha,&nbsp;Nabamita Goswami,&nbsp;Ardhendu Saha,&nbsp;Krishna Kanta Kakati","doi":"10.1007/s00340-024-08351-5","DOIUrl":null,"url":null,"abstract":"<div><p>An analytical study of wave theory-based multilayered SPR-based fiber optic biosensor by shinning Bessel-Gauss (BG) beam is proposed here for early diagnosis of dengue infection. At first, this wave theory-based analytical model shined by Gaussian (G) beam is validated with the already reported experimental data, where the obtained results are in good accord with the experimental findings presented by Y. M. Kamil et al. in 2018. So, it affords the experimental confirmation of the validity of the proposed theory. The enhancement in sensitivity is 1.99 times ascertained by employing G beam for our proposed structure at a spectral sensitivity of 10.008 nm/nM. This theoretical investigation has then been extended utilizing the BG beam, where the observed sensitivity is increased to 59,602.00 dB/RIU and 20.016 nm/nM with a resolution of 1.68 × 10<sup>–7</sup>, which is 3.98 times higher than the referred published work. Here, the limit of detection is 0.06 pM with a minimum change in transmitted output power of 0.8658 milliwatt/RIU. When the DENV-II E protein concentration ranges from 0.08 pM to 0.6 nM, higher spectral shifts are observed. Consequently, enhancements in sensitivity and resolution can be achieved at reduced concentrations, paving the idea of diagnosis of dengue infection at an early stage.</p></div>","PeriodicalId":474,"journal":{"name":"Applied Physics B","volume":"130 12","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Physics B","FirstCategoryId":"4","ListUrlMain":"https://link.springer.com/article/10.1007/s00340-024-08351-5","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

Abstract

An analytical study of wave theory-based multilayered SPR-based fiber optic biosensor by shinning Bessel-Gauss (BG) beam is proposed here for early diagnosis of dengue infection. At first, this wave theory-based analytical model shined by Gaussian (G) beam is validated with the already reported experimental data, where the obtained results are in good accord with the experimental findings presented by Y. M. Kamil et al. in 2018. So, it affords the experimental confirmation of the validity of the proposed theory. The enhancement in sensitivity is 1.99 times ascertained by employing G beam for our proposed structure at a spectral sensitivity of 10.008 nm/nM. This theoretical investigation has then been extended utilizing the BG beam, where the observed sensitivity is increased to 59,602.00 dB/RIU and 20.016 nm/nM with a resolution of 1.68 × 10–7, which is 3.98 times higher than the referred published work. Here, the limit of detection is 0.06 pM with a minimum change in transmitted output power of 0.8658 milliwatt/RIU. When the DENV-II E protein concentration ranges from 0.08 pM to 0.6 nM, higher spectral shifts are observed. Consequently, enhancements in sensitivity and resolution can be achieved at reduced concentrations, paving the idea of diagnosis of dengue infection at an early stage.

基于波浪理论的高灵敏光纤生物传感器在 BG 光束照射下用于登革热感染早期诊断的分析探索
本文提出了一种基于波理论的多层 SPR 光纤生物传感器的分析方法,该方法采用贝塞尔-高斯(BG)光束照射,用于登革热感染的早期诊断。首先,该基于波理论的分析模型通过高斯(G)光束照射与已报道的实验数据进行了验证,得到的结果与 Y. M. Kamil 等人在 2018 年提出的实验结果十分吻合。因此,实验证实了所提理论的正确性。在光谱灵敏度为 10.008 nm/nM 时,我们提出的结构采用 G 光束,灵敏度提高了 1.99 倍。随后,利用 BG 光束扩展了这一理论研究,观察到的灵敏度提高到 59,602.00 dB/RIU 和 20.016 nm/nM,分辨率为 1.68 × 10-7,比已发表的参考文献高出 3.98 倍。此处的检测极限为 0.06 pM,传输输出功率的最小变化为 0.8658 毫瓦/RIU。当 DENV-II E 蛋白浓度在 0.08 pM 至 0.6 nM 之间时,可观察到更高的光谱偏移。因此,降低浓度可提高灵敏度和分辨率,为早期诊断登革热感染铺平道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Physics B
Applied Physics B 物理-光学
CiteScore
4.00
自引率
4.80%
发文量
202
审稿时长
3.0 months
期刊介绍: Features publication of experimental and theoretical investigations in applied physics Offers invited reviews in addition to regular papers Coverage includes laser physics, linear and nonlinear optics, ultrafast phenomena, photonic devices, optical and laser materials, quantum optics, laser spectroscopy of atoms, molecules and clusters, and more 94% of authors who answered a survey reported that they would definitely publish or probably publish in the journal again Publishing essential research results in two of the most important areas of applied physics, both Applied Physics sections figure among the top most cited journals in this field. In addition to regular papers Applied Physics B: Lasers and Optics features invited reviews. Fields of topical interest are covered by feature issues. The journal also includes a rapid communication section for the speedy publication of important and particularly interesting results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信