Development and validation of the thyroidectomy training box: cervical simulator for training endoscopic transoral thyroidectomy.

Acta cirurgica brasileira Pub Date : 2024-11-08 eCollection Date: 2024-01-01 DOI:10.1590/acb397624
Valdenor Neves Feitosa, Taís Vasconcelos Cidrão, Ingrid Arruda Castro, Klayton Coelho de Souza Júnior, Sarah Rodrigues Chaves Martins, Francisco Everton Pereira da Silva, Luiz Gonzaga Moura Junior
{"title":"Development and validation of the thyroidectomy training box: cervical simulator for training endoscopic transoral thyroidectomy.","authors":"Valdenor Neves Feitosa, Taís Vasconcelos Cidrão, Ingrid Arruda Castro, Klayton Coelho de Souza Júnior, Sarah Rodrigues Chaves Martins, Francisco Everton Pereira da Silva, Luiz Gonzaga Moura Junior","doi":"10.1590/acb397624","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To develop and validate a trans oral endoscopic thyroidectomy vestibular approach (TOETVA) simulator.</p><p><strong>Methods: </strong>The first phase of the project consisted of designing and developing a transoral thyroid surgery simulator based on real surgeries. The product has the oral cavity for attaching the three trocars and the cervical part containing the thyroid and adjacent structures. In the second phase, the simulator was validated by specialists who performed an endoscopic thyroidectomy procedure. They all filled a questionnaire about the simulator and the simulation based on the Likert scale.</p><p><strong>Results: </strong>The simulator consists of a console similar to a human bust and a high-resolution camera system connected to a 22-inch monitor. The simulator had excellent results in the visual evaluation (face validity), with 100% of responses between good and excellent for the following characteristics: synthetic structures, design, visibility of the surgery field, resistance, resilience, fulcrum effect, ergonomics, surgical material, and practicality. The last three were rated higher, with more votes for excellent. For content validity, the items that received the best ratings were, precisely, the steps relating to the surgical procedure: opening the intermuscular midline, isthmotomy, and thyroidectomy.</p><p><strong>Conclusions: </strong>The thyroidectomy training box showed great ability to simulate a TOETVA, with satisfactory evaluations concerning its visual and content validation.</p>","PeriodicalId":93850,"journal":{"name":"Acta cirurgica brasileira","volume":"39 ","pages":"e397624"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548132/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta cirurgica brasileira","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/acb397624","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To develop and validate a trans oral endoscopic thyroidectomy vestibular approach (TOETVA) simulator.

Methods: The first phase of the project consisted of designing and developing a transoral thyroid surgery simulator based on real surgeries. The product has the oral cavity for attaching the three trocars and the cervical part containing the thyroid and adjacent structures. In the second phase, the simulator was validated by specialists who performed an endoscopic thyroidectomy procedure. They all filled a questionnaire about the simulator and the simulation based on the Likert scale.

Results: The simulator consists of a console similar to a human bust and a high-resolution camera system connected to a 22-inch monitor. The simulator had excellent results in the visual evaluation (face validity), with 100% of responses between good and excellent for the following characteristics: synthetic structures, design, visibility of the surgery field, resistance, resilience, fulcrum effect, ergonomics, surgical material, and practicality. The last three were rated higher, with more votes for excellent. For content validity, the items that received the best ratings were, precisely, the steps relating to the surgical procedure: opening the intermuscular midline, isthmotomy, and thyroidectomy.

Conclusions: The thyroidectomy training box showed great ability to simulate a TOETVA, with satisfactory evaluations concerning its visual and content validation.

甲状腺切除术训练箱的开发和验证:用于训练内窥镜经口甲状腺切除术的颈部模拟器。
目的:开发并验证经口内窥镜甲状腺切除术前庭入路(TOETVA)模拟器:项目的第一阶段包括设计和开发基于真实手术的经口甲状腺手术模拟器。该产品有用于连接三个套管的口腔和包含甲状腺及邻近结构的颈椎部分。在第二阶段,模拟器由实施过内窥镜甲状腺切除术的专家进行了验证。他们都根据李克特量表填写了一份关于模拟器和模拟的问卷:模拟器由一个类似人体半身像的控制台和一个连接到 22 英寸显示器的高分辨率摄像系统组成。模拟器在视觉评估(面效度)中取得了优异成绩,在以下特性方面,100%的回答介于 "好 "和 "优 "之间:合成结构、设计、手术区域的可视性、阻力、回弹力、支点效应、人体工程学、手术材料和实用性。后三项的评分较高,优秀票数较多。在内容有效性方面,获得最佳评分的项目恰恰是与手术过程有关的步骤:打开肌间中线、峡部切开术和甲状腺切除术:甲状腺切除术训练箱在模拟 TOETVA 方面表现出色,在视觉和内容验证方面都获得了令人满意的评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信