{"title":"Detection of early renal perfusion changes by contrast-enhanced ultrasonography in dogs with preclinical myxomatous mitral valve disease.","authors":"Saho Kamata, Tomoya Morita, Masahiro Yamasaki","doi":"10.1111/vru.13459","DOIUrl":null,"url":null,"abstract":"<p><p>Since the prognosis of myxomatous mitral valve disease (MMVD) varies, its characterization is clinically relevant, and renal impairment has been identified as one of its associated factors. Intrarenal Doppler ultrasonography (IRD), an intrarenal hemodynamic assessment method, is useful for predicting cardiac- and renal-related death but cannot detect early changes in dogs with preclinical MMVD. Contrast-enhanced ultrasonography (CEUS), another intrarenal hemodynamic assessment method, may identify earlier changes; however, renal perfusion evaluations using CEUS have not yet been performed on dogs with MMVD. We hypothesized that CEUS detects changes earlier than IRD in dogs with preclinical MMVD. This prospective, cross-sectional study examined renal perfusion in dogs without cardiac disease and preclinical MMVD dogs of different American College of Veterinary Internal Medicine stages using CEUS and compared it with IRD indices. Twenty-three dogs with MMVD (ten stage B1 and thirteen stage B2) and 12 control dogs without cardiac disease were included. The rise times of the renal cortex and medulla were measured from a time-intensity curve. The rise time of the cortex was longer in dogs with stage B2 MMVD than in control dogs, while that of the medulla was shortened in the right ventricular dysfunction group in stage B2. No changes were observed in IRD indices (the resistance index and venous impedance index). In conclusion, CEUS detected changes in renal perfusion in dogs with preclinical MMVD even when IRD indices remained unchanged, suggesting the utility of CEUS in evaluations of renal perfusion in MMVD dogs.</p>","PeriodicalId":23581,"journal":{"name":"Veterinary Radiology & Ultrasound","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Radiology & Ultrasound","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vru.13459","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Since the prognosis of myxomatous mitral valve disease (MMVD) varies, its characterization is clinically relevant, and renal impairment has been identified as one of its associated factors. Intrarenal Doppler ultrasonography (IRD), an intrarenal hemodynamic assessment method, is useful for predicting cardiac- and renal-related death but cannot detect early changes in dogs with preclinical MMVD. Contrast-enhanced ultrasonography (CEUS), another intrarenal hemodynamic assessment method, may identify earlier changes; however, renal perfusion evaluations using CEUS have not yet been performed on dogs with MMVD. We hypothesized that CEUS detects changes earlier than IRD in dogs with preclinical MMVD. This prospective, cross-sectional study examined renal perfusion in dogs without cardiac disease and preclinical MMVD dogs of different American College of Veterinary Internal Medicine stages using CEUS and compared it with IRD indices. Twenty-three dogs with MMVD (ten stage B1 and thirteen stage B2) and 12 control dogs without cardiac disease were included. The rise times of the renal cortex and medulla were measured from a time-intensity curve. The rise time of the cortex was longer in dogs with stage B2 MMVD than in control dogs, while that of the medulla was shortened in the right ventricular dysfunction group in stage B2. No changes were observed in IRD indices (the resistance index and venous impedance index). In conclusion, CEUS detected changes in renal perfusion in dogs with preclinical MMVD even when IRD indices remained unchanged, suggesting the utility of CEUS in evaluations of renal perfusion in MMVD dogs.
期刊介绍:
Veterinary Radiology & Ultrasound is a bimonthly, international, peer-reviewed, research journal devoted to the fields of veterinary diagnostic imaging and radiation oncology. Established in 1958, it is owned by the American College of Veterinary Radiology and is also the official journal for six affiliate veterinary organizations. Veterinary Radiology & Ultrasound is represented on the International Committee of Medical Journal Editors, World Association of Medical Editors, and Committee on Publication Ethics.
The mission of Veterinary Radiology & Ultrasound is to serve as a leading resource for high quality articles that advance scientific knowledge and standards of clinical practice in the areas of veterinary diagnostic radiology, computed tomography, magnetic resonance imaging, ultrasonography, nuclear imaging, radiation oncology, and interventional radiology. Manuscript types include original investigations, imaging diagnosis reports, review articles, editorials and letters to the Editor. Acceptance criteria include originality, significance, quality, reader interest, composition and adherence to author guidelines.