{"title":"Practical cut-off value for radon concentration in indoor air using an activated-charcoal radon collector.","authors":"Yumi Yasuoka, June Takemoto, Yasutaka Omori, Nanaho Kawamoto, Nao Goda, Hiroyuki Nagahama, Jun Muto, Shinji Tokonami, Masahiro Hosoda, Takeshi Iimoto, Takahiro Mukai","doi":"10.1093/rpd/ncae108","DOIUrl":null,"url":null,"abstract":"<p><p>The World Health Organization (WHO) recommends that countries adopt the reference level of 100 Bq m-3 for indoor radon gas. Adopting the reference level requires a preliminary assessment of the indoor radon concentration. In the preliminary investigation, a cut-off value is useful, which is a value for selecting samples that can be reliably determined to be below the reference level (in this paper, the WHO reference level) using a straightforward method. If the true value was the WHO reference level, then the cut-off value of the PicoRad collector for selecting samples was determined as 80 Bq m-3 through the analysis of the 95% prediction interval.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":"200 16-18","pages":"1701-1705"},"PeriodicalIF":0.8000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11561575/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae108","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
The World Health Organization (WHO) recommends that countries adopt the reference level of 100 Bq m-3 for indoor radon gas. Adopting the reference level requires a preliminary assessment of the indoor radon concentration. In the preliminary investigation, a cut-off value is useful, which is a value for selecting samples that can be reliably determined to be below the reference level (in this paper, the WHO reference level) using a straightforward method. If the true value was the WHO reference level, then the cut-off value of the PicoRad collector for selecting samples was determined as 80 Bq m-3 through the analysis of the 95% prediction interval.
期刊介绍:
Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.