The Role of High-Resolution Ultrasound in the Diagnosis of Nerve Trauma New Perspective: A Preliminary Systematic Review and Meta-Analysis of the Recent Evidence.
Aya Moustafa Aboutaleb, Ezzeldin Abouelatta, Talal Salem, Abdelbaki Idriss Ibrahim, Aya Sayed Serour, Nagham Bushara Abbas, Rana Ahmed Youssef, Osama Omar Ballut, Reda Ibrahim Shehta, Merna Wagih Awad, Khaled Walid Hassan, Hasnaa Ali Hassan Abdelrhem, Mona Ali, Mostafa Badr, Shady Sherif Mohamed Aref, Mohamed Abdelmohsen Bedewi, Khaled Ashraf Mohamed, Hubertus Axer, Ramy Abdelnaby
{"title":"The Role of High-Resolution Ultrasound in the Diagnosis of Nerve Trauma New Perspective: A Preliminary Systematic Review and Meta-Analysis of the Recent Evidence.","authors":"Aya Moustafa Aboutaleb, Ezzeldin Abouelatta, Talal Salem, Abdelbaki Idriss Ibrahim, Aya Sayed Serour, Nagham Bushara Abbas, Rana Ahmed Youssef, Osama Omar Ballut, Reda Ibrahim Shehta, Merna Wagih Awad, Khaled Walid Hassan, Hasnaa Ali Hassan Abdelrhem, Mona Ali, Mostafa Badr, Shady Sherif Mohamed Aref, Mohamed Abdelmohsen Bedewi, Khaled Ashraf Mohamed, Hubertus Axer, Ramy Abdelnaby","doi":"10.1097/WNP.0000000000001126","DOIUrl":null,"url":null,"abstract":"<p><strong>Summary: </strong>Precise localization of peripheral nerve injuries and evaluation of their prognosis based on clinical and electrodiagnostic examinations are particularly challenging in the acute phase. High-resolution ultrasound (HRUS) may offer a viable and cost-effective imaging option for assessing the morphology of nerve injuries. Consequently, a systematic review and meta-analysis of studies on the use of ultrasound for diagnosing traumatic nerve injuries were conducted. A total of 15 studies were included, reporting the most recent findings on using HRUS in the diagnosis of traumatic nerve injury. These studies assessed the diagnostic test accuracy of ultrasound for the detection of traumatic nerve injury in 272 participants, with the cross-sectional area at the site of traumatic nerve injury also reported in 1,249 participants. The pooled sensitivity and specificity of the included studies were 92% confidence interval (CI) (0.89-0.95) and 86% CI (0.82-0.89), respectively. The positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 13.76 CI (1.41-134.34), 0.08 CI (0.03-0.18), and 286.23 CI (21.22-3,860.40), respectively. In the summary of the receiver operating characteristic curve, the area under the curve was 0.986, and the Q* index was 0.949. Based on the current literature, HRUS has shown promising results in addition to its availability and feasibility. HRUS can serve as a valuable complement to clinical and electrodiagnostic examinations for diagnosing traumatic peripheral nerve injuries. Further research is recommended to better understand the ultrasound characteristics of these injuries.</p>","PeriodicalId":15516,"journal":{"name":"Journal of Clinical Neurophysiology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Neurophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/WNP.0000000000001126","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Summary: Precise localization of peripheral nerve injuries and evaluation of their prognosis based on clinical and electrodiagnostic examinations are particularly challenging in the acute phase. High-resolution ultrasound (HRUS) may offer a viable and cost-effective imaging option for assessing the morphology of nerve injuries. Consequently, a systematic review and meta-analysis of studies on the use of ultrasound for diagnosing traumatic nerve injuries were conducted. A total of 15 studies were included, reporting the most recent findings on using HRUS in the diagnosis of traumatic nerve injury. These studies assessed the diagnostic test accuracy of ultrasound for the detection of traumatic nerve injury in 272 participants, with the cross-sectional area at the site of traumatic nerve injury also reported in 1,249 participants. The pooled sensitivity and specificity of the included studies were 92% confidence interval (CI) (0.89-0.95) and 86% CI (0.82-0.89), respectively. The positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 13.76 CI (1.41-134.34), 0.08 CI (0.03-0.18), and 286.23 CI (21.22-3,860.40), respectively. In the summary of the receiver operating characteristic curve, the area under the curve was 0.986, and the Q* index was 0.949. Based on the current literature, HRUS has shown promising results in addition to its availability and feasibility. HRUS can serve as a valuable complement to clinical and electrodiagnostic examinations for diagnosing traumatic peripheral nerve injuries. Further research is recommended to better understand the ultrasound characteristics of these injuries.
期刊介绍:
The Journal of Clinical Neurophysiology features both topical reviews and original research in both central and peripheral neurophysiology, as related to patient evaluation and treatment.
Official Journal of the American Clinical Neurophysiology Society.