Minimum perceptual time (MPT). Repeatability and reproducibility of variables applied to "sports vision".

IF 2.4 3区 医学 Q2 OPHTHALMOLOGY
Antonio Ríder-Vázquez, Margarita Vega-Holm, María Carmen Sánchez-González, Estanislao Gutiérrez-Sánchez
{"title":"Minimum perceptual time (MPT). Repeatability and reproducibility of variables applied to \"sports vision\".","authors":"Antonio Ríder-Vázquez, Margarita Vega-Holm, María Carmen Sánchez-González, Estanislao Gutiérrez-Sánchez","doi":"10.1007/s00417-024-06684-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>\"Minimum Perceptual Time\" (MPT) is the ability to take the most visual information in the least time. The purpose of the study was to assess intraobserver and interobserver repeatability of a MPT measurement method by using COI-SV<sup>®</sup> software and to analyze the possible influence of age and sex.</p><p><strong>Methods: </strong>MPT was measured in 79 participants by using COI-SV<sup>®</sup> software. Visual acuity was 20/80 (2.50 m) and numbers were gradually increasing in quantity and decreasing in exposure time. The most quantity of numbers and the least time was written down. To assess intraobserver and interobserver repeatability, a protocol based on repeating the test 4 times (2 intrasession and 2 intersessions with 2 examinators) was established. Comparison of means and Spearman correlation were performed to evaluate the influence of sex and age. It was investigated inter and intraexaminer variability using repeatability indices, as well as Bland-Altman analysis to define limits of agreement.</p><p><strong>Results: </strong>A total of 79 participants were included (mean age 32.8 ± 11.95 years, range 19-64 years). Regarding sex, there were no significant differences between men and women (p = 0.080), whereas age and MPT had an inverse correlation (p = 0.01). Interexaminer and intraexaminer repeatability proved to be moderate to good in all methods. Bland-Altman showed difference between sessions was 0.259 ± 2.189 (-4.030 and + 4.549) and difference between examiners was - 0.519 ± 2.104 (-4.642 and + 3.604).</p><p><strong>Conclusion: </strong>MPT measurements with COI-SV<sup>®</sup> software evidenced moderate to good repeatability and observers` independent result, so it could be included in optometric examinations.</p><p><strong>Key messages: </strong>WHAT IS KNOWN : Sports optometry is a relatively new field, so research is scarce and of poor quality. The scarcity of literature is practically limited to studies in the field of psychology, although they do not provide us with much information since they have not been studied for the mentioned field. The in-depth study of new standardized measurement methods would be of great help for optometrists in their clinical practice.</p><p><strong>What is new: </strong>This study is the first to determine intraobserver and interobserver repeatability and reproducibility for Minimum Perceptual Time (MPT) measurements acquired by the COI-SV® software, exhibiting ICC > 0.7 and establishing limits of agreement by using Bland-Altman analysis. In a significant way, MPT and age would have an inverse correlation, whereas MPT results would be better in men than women. Our results add evidence towards validating the test included in COI-SV® software so that the optometrist can include it in their clinical protocols in order to obtain more complete information on visual examinations.</p>","PeriodicalId":12795,"journal":{"name":"Graefe’s Archive for Clinical and Experimental Ophthalmology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe’s Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-024-06684-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: "Minimum Perceptual Time" (MPT) is the ability to take the most visual information in the least time. The purpose of the study was to assess intraobserver and interobserver repeatability of a MPT measurement method by using COI-SV® software and to analyze the possible influence of age and sex.

Methods: MPT was measured in 79 participants by using COI-SV® software. Visual acuity was 20/80 (2.50 m) and numbers were gradually increasing in quantity and decreasing in exposure time. The most quantity of numbers and the least time was written down. To assess intraobserver and interobserver repeatability, a protocol based on repeating the test 4 times (2 intrasession and 2 intersessions with 2 examinators) was established. Comparison of means and Spearman correlation were performed to evaluate the influence of sex and age. It was investigated inter and intraexaminer variability using repeatability indices, as well as Bland-Altman analysis to define limits of agreement.

Results: A total of 79 participants were included (mean age 32.8 ± 11.95 years, range 19-64 years). Regarding sex, there were no significant differences between men and women (p = 0.080), whereas age and MPT had an inverse correlation (p = 0.01). Interexaminer and intraexaminer repeatability proved to be moderate to good in all methods. Bland-Altman showed difference between sessions was 0.259 ± 2.189 (-4.030 and + 4.549) and difference between examiners was - 0.519 ± 2.104 (-4.642 and + 3.604).

Conclusion: MPT measurements with COI-SV® software evidenced moderate to good repeatability and observers` independent result, so it could be included in optometric examinations.

Key messages: WHAT IS KNOWN : Sports optometry is a relatively new field, so research is scarce and of poor quality. The scarcity of literature is practically limited to studies in the field of psychology, although they do not provide us with much information since they have not been studied for the mentioned field. The in-depth study of new standardized measurement methods would be of great help for optometrists in their clinical practice.

What is new: This study is the first to determine intraobserver and interobserver repeatability and reproducibility for Minimum Perceptual Time (MPT) measurements acquired by the COI-SV® software, exhibiting ICC > 0.7 and establishing limits of agreement by using Bland-Altman analysis. In a significant way, MPT and age would have an inverse correlation, whereas MPT results would be better in men than women. Our results add evidence towards validating the test included in COI-SV® software so that the optometrist can include it in their clinical protocols in order to obtain more complete information on visual examinations.

最短感知时间(MPT)。应用于 "运动视觉 "的变量的可重复性和再现性。
目的:"最短知觉时间"(MPT)是指在最短时间内获取最多视觉信息的能力。本研究旨在使用 COI-SV® 软件评估 MPT 测量方法的观察者内和观察者间的可重复性,并分析年龄和性别可能造成的影响:使用 COI-SV® 软件测量了 79 名参与者的 MPT。视力为 20/80 (2.50 m),数字数量逐渐增加,曝光时间逐渐缩短。数量最多、时间最少的数字被记录下来。为了评估观察者内部和观察者之间的可重复性,制定了一个重复测试 4 次的方案(2 次会期内测试和 2 次会期间测试,由 2 名检查员进行)。为评估性别和年龄的影响,进行了均值比较和斯皮尔曼相关性分析。使用重复性指数对检查者之间和检查者内部的变异性进行了调查,并使用布兰-阿尔特曼分析法确定了一致性的界限:结果:共纳入 79 名参与者(平均年龄为 32.8 ± 11.95 岁,年龄范围为 19-64 岁)。性别方面,男女之间无明显差异(p = 0.080),而年龄与 MPT 呈反向相关(p = 0.01)。在所有方法中,检查者之间和检查者内部的重复性被证明为中等至良好。Bland-Altman显示,不同疗程之间的差异为0.259 ± 2.189 (-4.030 and + 4.549),不同检查者之间的差异为- 0.519 ± 2.104 (-4.642 and + 3.604):结论:使用 COI-SV® 软件进行的 MPT 测量具有中等至良好的重复性和观察者的独立结果,因此可将其纳入视力检查:已知信息:运动视光学是一个相对较新的领域,因此研究很少且质量不高。文献的匮乏实际上仅限于心理学领域的研究,但这些研究并没有为我们提供太多的信息,因为它们并没有针对上述领域进行过研究。对新的标准化测量方法的深入研究将对视光师的临床实践大有帮助。新内容:本研究首次确定了通过 COI-SV® 软件获取的最短知觉时间 (MPT) 测量的观察者内和观察者间的重复性和再现性,显示 ICC > 0.7,并使用 Bland-Altman 分析确定了一致性的界限。在很大程度上,最小感知时间与年龄呈反相关,而男性的最小感知时间结果优于女性。我们的结果为验证 COI-SV® 软件中的测试增加了证据,这样验光师就可以将其纳入临床方案,从而获得更全面的视力检查信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.40
自引率
7.40%
发文量
398
审稿时长
3 months
期刊介绍: Graefe''s Archive for Clinical and Experimental Ophthalmology is a distinguished international journal that presents original clinical reports and clini-cally relevant experimental studies. Founded in 1854 by Albrecht von Graefe to serve as a source of useful clinical information and a stimulus for discussion, the journal has published articles by leading ophthalmologists and vision research scientists for more than a century. With peer review by an international Editorial Board and prompt English-language publication, Graefe''s Archive provides rapid dissemination of clinical and clinically related experimental information.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信