Detection of a Water-Soluble Hypericin Formulation in Glioblastoma Tissue with Fluorescence Lifetime and Intensity Using a Dual-Tap CMOS Camera System.

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Mario Mischkulnig, David Reichert, Lionel Wightman, Vanessa Roth, Marijke Hölz, Lisa I Körner, Barbara Kiesel, Djenana Vejzovic, Gabriel A Giardina, Mikael T Erkkilae, Angelika Unterhuber, Marco Andreana, Beate Rinner, Andreas Kubin, Rainer Leitgeb, Georg Widhalm
{"title":"Detection of a Water-Soluble Hypericin Formulation in Glioblastoma Tissue with Fluorescence Lifetime and Intensity Using a Dual-Tap CMOS Camera System.","authors":"Mario Mischkulnig, David Reichert, Lionel Wightman, Vanessa Roth, Marijke Hölz, Lisa I Körner, Barbara Kiesel, Djenana Vejzovic, Gabriel A Giardina, Mikael T Erkkilae, Angelika Unterhuber, Marco Andreana, Beate Rinner, Andreas Kubin, Rainer Leitgeb, Georg Widhalm","doi":"10.3390/diagnostics14212423","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>High hypericin-loaded polyvinylpyrrolidone (HHL-PVP) constitutes a novel approach to utilize the promising characteristics of hypericin for photodynamic diagnosis (PDD) and therapy (PDT) of brain tumors in an orally bioavailable formulation. The aim of this study was to investigate the ability of a Complementary Metal-Oxide-Semiconductor (CMOS) camera-based fluorescence imaging system to selectively visualize HHL-PVP in glioblastoma tissue even in the presence of 5-Aminolvevulinic acid (5-ALA) induced fluorescence, which is widely utilized in brain tumor surgery.</p><p><strong>Methods: </strong>We applied a previously established system with a non-hypericin specific filter for 5-ALA fluorescence visualization and a newly introduced hypericin-specific filter at 575-615 nm that transmits the spectrum of hypericin, but not 5-ALA fluorescence. Glioblastoma specimens obtained from 12 patients (11 with preoperative 5-ALA intake) were ex vivo incubated with HHL-PVP. Subsequently, fluorescence intensity and lifetime changes using both the non-hypericin specific filter and hypericin-specific filter were measured before and after HHL-PVP incubation and after subsequent rinsing.</p><p><strong>Results: </strong>While no significant differences in fluorescence signal were observed using the non-hypericin specific filter, statistically significant increases in fluorescence intensity (<i>p</i> = 0.001) and lifetime (<i>p</i> = 0.028) after HHL-PVP incubation were demonstrated using the hypericin-specific filter. In consequence, specimens treated with HHL-PVP could be identified according to the fluorescence signal with high diagnostic sensitivity (87.5%) and specificity (100%).</p><p><strong>Conclusions: </strong>Our CMOS camera-based system with a hypericin-specific filter is capable of selectively visualizing hypericin fluorescence in glioblastoma tissue after ex vivo HHL-PVP incubation. In the future, this technique could facilitate clinical investigations of HHL-PVP for PDD and PDT while maintaining the current standard of care with 5-ALA guidance.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"14 21","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11545445/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics14212423","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: High hypericin-loaded polyvinylpyrrolidone (HHL-PVP) constitutes a novel approach to utilize the promising characteristics of hypericin for photodynamic diagnosis (PDD) and therapy (PDT) of brain tumors in an orally bioavailable formulation. The aim of this study was to investigate the ability of a Complementary Metal-Oxide-Semiconductor (CMOS) camera-based fluorescence imaging system to selectively visualize HHL-PVP in glioblastoma tissue even in the presence of 5-Aminolvevulinic acid (5-ALA) induced fluorescence, which is widely utilized in brain tumor surgery.

Methods: We applied a previously established system with a non-hypericin specific filter for 5-ALA fluorescence visualization and a newly introduced hypericin-specific filter at 575-615 nm that transmits the spectrum of hypericin, but not 5-ALA fluorescence. Glioblastoma specimens obtained from 12 patients (11 with preoperative 5-ALA intake) were ex vivo incubated with HHL-PVP. Subsequently, fluorescence intensity and lifetime changes using both the non-hypericin specific filter and hypericin-specific filter were measured before and after HHL-PVP incubation and after subsequent rinsing.

Results: While no significant differences in fluorescence signal were observed using the non-hypericin specific filter, statistically significant increases in fluorescence intensity (p = 0.001) and lifetime (p = 0.028) after HHL-PVP incubation were demonstrated using the hypericin-specific filter. In consequence, specimens treated with HHL-PVP could be identified according to the fluorescence signal with high diagnostic sensitivity (87.5%) and specificity (100%).

Conclusions: Our CMOS camera-based system with a hypericin-specific filter is capable of selectively visualizing hypericin fluorescence in glioblastoma tissue after ex vivo HHL-PVP incubation. In the future, this technique could facilitate clinical investigations of HHL-PVP for PDD and PDT while maintaining the current standard of care with 5-ALA guidance.

使用双抽头 CMOS 照相机系统利用荧光寿命和强度检测胶质母细胞瘤组织中的水溶性金丝桃素制剂
背景:高金丝霉素负载聚乙烯吡咯烷酮(HHL-PVP)是利用金丝霉素的良好特性对脑肿瘤进行光动力诊断(PDD)和治疗(PDT)的一种新型口服生物可用制剂。本研究旨在探讨基于互补金属氧化物半导体(CMOS)相机的荧光成像系统在脑肿瘤手术中广泛使用的5-氨基乙酰丙酸(5-ALA)诱导荧光存在的情况下选择性地观察胶质母细胞瘤组织中HHL-PVP的能力:方法:我们采用了一种先前建立的系统,该系统使用非金丝桃素特异性滤光片来观察 5-ALA 荧光,同时还使用了一种新引入的 575-615 nm 波长的金丝桃素特异性滤光片,该滤光片能透过金丝桃素光谱,但不能透过 5-ALA 荧光。用 HHL-PVP 对 12 名患者(其中 11 人术前摄入了 5-ALA)的胶质母细胞瘤标本进行体外培养。随后,使用非过霉素特异性滤光片和过霉素特异性滤光片测量 HHL-PVP 培养前后及随后冲洗后的荧光强度和寿命变化:虽然使用非金丝桃素特异性滤光片观察到的荧光信号无明显差异,但使用金丝桃素特异性滤光片观察到 HHL-PVP 培养后荧光强度(p = 0.001)和荧光寿命(p = 0.028)均有统计学意义的明显增加。因此,使用 HHL-PVP 处理的标本可根据荧光信号进行鉴定,诊断灵敏度(87.5%)和特异性(100%)都很高:结论:我们的基于CMOS相机的系统带有金丝桃素特异性滤光片,能够选择性地观察体内HHL-PVP培养后胶质母细胞瘤组织中的金丝桃素荧光。未来,这项技术将有助于将 HHL-PVP 用于 PDD 和 PDT 的临床研究,同时保持目前 5-ALA 引导的治疗标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信