Prosthetic Valve Fate in Patients With Continuous-Flow Left Ventricular Assist Devices.

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Daisuke Kaneyuki, Krushang Patel, Alice V Vinogradsky, Kavya Rajesh, Melissa A Hynds, Paul A Kurlansky, Melana Yuzefpolskaya, Paolo C Colombo, Gabriel T Sayer, Nir Uriel, Yoshifumi Naka, Koji Takeda
{"title":"Prosthetic Valve Fate in Patients With Continuous-Flow Left Ventricular Assist Devices.","authors":"Daisuke Kaneyuki, Krushang Patel, Alice V Vinogradsky, Kavya Rajesh, Melissa A Hynds, Paul A Kurlansky, Melana Yuzefpolskaya, Paolo C Colombo, Gabriel T Sayer, Nir Uriel, Yoshifumi Naka, Koji Takeda","doi":"10.1097/MAT.0000000000002345","DOIUrl":null,"url":null,"abstract":"<p><p>Prosthetic valve-related morbidity and mortality in patients with left ventricular assist devices (LVADs) remain unclear. We retrospectively reviewed patients who received a HeartMate II or 3 LVAD at our center between April 2004 and December 2022. Patients with a valve prosthesis in any position were included. Of the 726 LVAD recipients, 74 (10.2%) underwent valve replacement before (n = 37, 50.0%), concomitantly with (n = 32, 43.2%), or after (n = 6, 8.1%) LVAD insertion. Prosthetic valves were implanted in the aortic (n = 32), mitral (n = 23), and tricuspid (n = 26) positions. Mechanical valves were present in eight (three aortic, five mitral) patients. At a median follow-up of 1.97 years post-VAD (interquartile range [IQR]: 0.56-4.58 years), there was one valve-related death due to severe aortic bioprosthetic insufficiency. Five of 28 (17.9%) patients with an aortic bioprosthesis had evidence of dysfunction on follow-up echocardiography. Median time to first sign of aortic bioprosthetic valve dysfunction was 1 (IQR: 0.6-5.1) year from time of LVAD with the prosthesis in place and 10.8 (IQR: 9.5-12.6) years from date of initial valve insertion. Prosthetic valve-related mortality or reinterventions are uncommon in patients with LVADs; however, bioprosthetic aortic valve dysfunction can develop less than 1 year after LVAD implantation.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002345","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Prosthetic valve-related morbidity and mortality in patients with left ventricular assist devices (LVADs) remain unclear. We retrospectively reviewed patients who received a HeartMate II or 3 LVAD at our center between April 2004 and December 2022. Patients with a valve prosthesis in any position were included. Of the 726 LVAD recipients, 74 (10.2%) underwent valve replacement before (n = 37, 50.0%), concomitantly with (n = 32, 43.2%), or after (n = 6, 8.1%) LVAD insertion. Prosthetic valves were implanted in the aortic (n = 32), mitral (n = 23), and tricuspid (n = 26) positions. Mechanical valves were present in eight (three aortic, five mitral) patients. At a median follow-up of 1.97 years post-VAD (interquartile range [IQR]: 0.56-4.58 years), there was one valve-related death due to severe aortic bioprosthetic insufficiency. Five of 28 (17.9%) patients with an aortic bioprosthesis had evidence of dysfunction on follow-up echocardiography. Median time to first sign of aortic bioprosthetic valve dysfunction was 1 (IQR: 0.6-5.1) year from time of LVAD with the prosthesis in place and 10.8 (IQR: 9.5-12.6) years from date of initial valve insertion. Prosthetic valve-related mortality or reinterventions are uncommon in patients with LVADs; however, bioprosthetic aortic valve dysfunction can develop less than 1 year after LVAD implantation.

持续流左心室辅助装置患者的人工瓣膜命运。
左心室辅助装置(LVAD)患者与人工瓣膜相关的发病率和死亡率仍不清楚。我们对 2004 年 4 月至 2022 年 12 月期间在本中心接受 HeartMate II 或 3 LVAD 的患者进行了回顾性研究。我们纳入了在任何位置安装了瓣膜假体的患者。在 726 名 LVAD 接受者中,74 人(10.2%)在植入 LVAD 之前(37 人,50.0%)、同时(32 人,43.2%)或之后(6 人,8.1%)接受了瓣膜置换术。人工瓣膜分别植入主动脉(32 例)、二尖瓣(23 例)和三尖瓣(26 例)。8例患者(3例主动脉瓣,5例二尖瓣)植入了机械瓣膜。在 VAD 术后 1.97 年(四分位数间距 [IQR]:0.56-4.58 年)的中位随访中,有一名患者因严重的主动脉生物假体功能不全而死于瓣膜相关疾病。28名使用主动脉生物假体的患者中有5名(17.9%)在随访超声心动图检查中发现功能障碍。首次出现主动脉生物假体瓣膜功能障碍的中位时间为 1 年(IQR:0.6-5.1),从植入假体的 LVAD 开始算起;10.8 年(IQR:9.5-12.6),从首次植入瓣膜开始算起。在使用 LVAD 的患者中,与人工瓣膜相关的死亡或再干预并不常见;但是,在 LVAD 植入后不到 1 年的时间内,就会出现生物人工主动脉瓣功能障碍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ASAIO Journal
ASAIO Journal 医学-工程:生物医学
CiteScore
6.60
自引率
7.10%
发文量
651
审稿时长
4-8 weeks
期刊介绍: ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world. The official publication of the American Society for Artificial Internal Organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信