Yi Zhao, Yuyu Ge, Wenfeng Chen, Shuai Chen, Zhiqiang Wang
{"title":"Upper airway hydrodynamics changes after molar distalization with aligners in adult patients.","authors":"Yi Zhao, Yuyu Ge, Wenfeng Chen, Shuai Chen, Zhiqiang Wang","doi":"10.1007/s00784-024-06029-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this study was to evaluate the changes of upper airway ventilation function after molar distalization with aligners in adult patients by computational fluid dynamic simulation.</p><p><strong>Materials and methods: </strong>A total of 15 subjects were included (3 males and 12 females, with an average age of 20.00 ± 0.50 years) who required en masse distal movement of the whole dentition using Invisalign aligners. The software Mimics 19.0 was used to reconstruct the upper airway based on their CBCT images and measure the minimum cross-sectional area and volume before and after treatment. Then the upper airway flow during inspirations was simulated and evaluated using Ansys software. At last, the morphologic and hydrodynamic parameters before and after treatment were compared using paired T-test.</p><p><strong>Results: </strong>For morphological evaluation, the volume changes of velopharynx, glossopharynx and hypopharynx volume revealed no statistically significance after treatment compared to the data before treatment, the minimum cross section of upper airway decreased significantly. For hydrodynamics parameters, the minimum pressure, maximum shear force, velopharynx and glossopharynx pressure drop increased 50.2 Pa, 0.66 Pa, 5.78 Pa and 5.32 Pa respectively. At last, the correlation analysis between CFD data and MCA is of no statistical significance.</p><p><strong>Conclusion: </strong>Non-extraction molar distalization using invisible aligners and mini-screws may lead to adverse changes in upper airway fluid dynamics, potentially increasing the risk of pharyngeal collapse.</p><p><strong>Clinical relevance: </strong>The combination of invisible appliances with anchorage implants for the distalization of maxillary and/or mandibular teeth has emerged as a prevalent orthodontic technique. Clinicians should consider the potential impact on respiratory function when contemplating such treatment for patients with pre-existing respiratory conditions or those at a higher risk of ventilation issues.</p>","PeriodicalId":10461,"journal":{"name":"Clinical Oral Investigations","volume":"28 12","pages":"630"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Investigations","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00784-024-06029-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The aim of this study was to evaluate the changes of upper airway ventilation function after molar distalization with aligners in adult patients by computational fluid dynamic simulation.
Materials and methods: A total of 15 subjects were included (3 males and 12 females, with an average age of 20.00 ± 0.50 years) who required en masse distal movement of the whole dentition using Invisalign aligners. The software Mimics 19.0 was used to reconstruct the upper airway based on their CBCT images and measure the minimum cross-sectional area and volume before and after treatment. Then the upper airway flow during inspirations was simulated and evaluated using Ansys software. At last, the morphologic and hydrodynamic parameters before and after treatment were compared using paired T-test.
Results: For morphological evaluation, the volume changes of velopharynx, glossopharynx and hypopharynx volume revealed no statistically significance after treatment compared to the data before treatment, the minimum cross section of upper airway decreased significantly. For hydrodynamics parameters, the minimum pressure, maximum shear force, velopharynx and glossopharynx pressure drop increased 50.2 Pa, 0.66 Pa, 5.78 Pa and 5.32 Pa respectively. At last, the correlation analysis between CFD data and MCA is of no statistical significance.
Conclusion: Non-extraction molar distalization using invisible aligners and mini-screws may lead to adverse changes in upper airway fluid dynamics, potentially increasing the risk of pharyngeal collapse.
Clinical relevance: The combination of invisible appliances with anchorage implants for the distalization of maxillary and/or mandibular teeth has emerged as a prevalent orthodontic technique. Clinicians should consider the potential impact on respiratory function when contemplating such treatment for patients with pre-existing respiratory conditions or those at a higher risk of ventilation issues.
期刊介绍:
The journal Clinical Oral Investigations is a multidisciplinary, international forum for publication of research from all fields of oral medicine. The journal publishes original scientific articles and invited reviews which provide up-to-date results of basic and clinical studies in oral and maxillofacial science and medicine. The aim is to clarify the relevance of new results to modern practice, for an international readership. Coverage includes maxillofacial and oral surgery, prosthetics and restorative dentistry, operative dentistry, endodontics, periodontology, orthodontics, dental materials science, clinical trials, epidemiology, pedodontics, oral implant, preventive dentistiry, oral pathology, oral basic sciences and more.