CDRA on Concave Conformal GP Loaded With Conformal FSS for Biomedical Applications

IF 2.2 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Manshree Mishra;Garima Tiwari;Pramod Kumar Gupta;Atul Kumar;Biswajeet Mukherjee
{"title":"CDRA on Concave Conformal GP Loaded With Conformal FSS for Biomedical Applications","authors":"Manshree Mishra;Garima Tiwari;Pramod Kumar Gupta;Atul Kumar;Biswajeet Mukherjee","doi":"10.1109/LSENS.2024.3481258","DOIUrl":null,"url":null,"abstract":"The development of a conformal frequency selective surface (FSS) loaded on a conformal cylindrical dielectric resonator antenna (CDRA) for the improvement of radiation characteristics for \n<italic>C</i>\n band applications is presented in this letter. Sinusoidal slot aperture feeding is used for the excitation of the proposed structure. Perturbation on the CDRA is used to improve the impedance bandwidth of an antenna. For obtaining the circular polarization, CDRA is loaded with a conformal FSS at a distance of (2n ± 1) λ/4. To minimize radiation exposure to nearby human bodies, specific absorption rate (SAR) value is calculated, which is less than the 1.6 W/Kg, and the SAR value decreases as the distance between DRA and human head increases. The proposed structure is fabricated, and the measured results are in close agreement with simulated results.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"8 11","pages":"1-4"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10717433/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The development of a conformal frequency selective surface (FSS) loaded on a conformal cylindrical dielectric resonator antenna (CDRA) for the improvement of radiation characteristics for C band applications is presented in this letter. Sinusoidal slot aperture feeding is used for the excitation of the proposed structure. Perturbation on the CDRA is used to improve the impedance bandwidth of an antenna. For obtaining the circular polarization, CDRA is loaded with a conformal FSS at a distance of (2n ± 1) λ/4. To minimize radiation exposure to nearby human bodies, specific absorption rate (SAR) value is calculated, which is less than the 1.6 W/Kg, and the SAR value decreases as the distance between DRA and human head increases. The proposed structure is fabricated, and the measured results are in close agreement with simulated results.
用于生物医学应用的凹面共形 GP 加载共形 FSS 的 CDRA
本信介绍了在共形圆柱介质谐振器天线(CDRA)上加载共形频率选择表面(FSS)的开发情况,以改善 C 波段应用的辐射特性。正弦槽孔馈电用于激励所提议的结构。CDRA 上的扰动用于改善天线的阻抗带宽。为了获得圆极化,CDRA 在 (2n ± 1) λ/4 的距离上装载了共形 FSS。为了尽量减少对附近人体的辐射,计算出的比吸收率(SAR)值小于 1.6 W/Kg,且 SAR 值随着 DRA 与人体头部距离的增加而降低。对所提出的结构进行了制作,测量结果与模拟结果非常吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Sensors Letters
IEEE Sensors Letters Engineering-Electrical and Electronic Engineering
CiteScore
3.50
自引率
7.10%
发文量
194
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信