Model-based thermodynamic analysis of direct air capture units in repurposed power plant cooling towers

IF 10.1 1区 工程技术 Q1 ENERGY & FUELS
Robert Sager , Lukas Pehle , Nils Hendrik Petersen , Manfred Wirsum , Jens Hannes
{"title":"Model-based thermodynamic analysis of direct air capture units in repurposed power plant cooling towers","authors":"Robert Sager ,&nbsp;Lukas Pehle ,&nbsp;Nils Hendrik Petersen ,&nbsp;Manfred Wirsum ,&nbsp;Jens Hannes","doi":"10.1016/j.apenergy.2024.124668","DOIUrl":null,"url":null,"abstract":"<div><div>To achieve the climate goals, the energy supply system must be sourced by renewable energy instead of fossil fuels. Nevertheless, hard-to-abate sectors require negative emission technologies (NETs) to counteract their emissions. Thus, NETs play a significant role across all future scenarios considered. Since natural NETs, such as afforestation, exhibit lower scaling potential, technological approaches like Direct Air Capture (DAC) represent promising alternatives. However, DAC faces major drawbacks in terms of high energy demands and high required air mass flows due to the low CO<sub>2</sub> concentration in ambient air (<span><math><mo>∼</mo></math></span>400 ppm). This results in elevated costs per captured tonne of CO<sub>2</sub>. Interestingly, the infrastructure of thermal power plants shares similarities with components of DAC units, in particular the cooling tower due to its handling of high air mass flows. As countries progressively shut down their coal-fired power plants, there is an opportunity to repurpose existing power plant infrastructure into DAC units.</div><div>Thus, this work investigates the opportunities and challenges of repurposing thermal power plant cooling towers as air contactors of DAC units with a potential of several million tonnes of CO<sub>2</sub> captured per year. The investigation focuses on the integration of an absorption-based liquid DAC process into a wet cooling tower. Therefore, the influence of the repurposed geometry of the cooling tower and its internal packing on the operational behavior of the air contactor is analyzed for the cooling towers of the coal power Niederaußem in Germany using a two-film theory-based model. It can be observed that the repurposed geometry of the absorber enables higher air velocities due to lower pressure losses. At the same time, the reduced travel depth in cooling towers causes a lower capture rate than in geometries optimized for DAC, ultimately resulting in 50–150 t<span><math><msub><mrow></mrow><mrow><msub><mrow><mi>CO</mi></mrow><mrow><mn>2</mn></mrow></msub></mrow></msub></math></span>/a per cooling tower. Finally, a sensitivity analysis shows that the effect of the correlations of mass transfer and volume specific surface areas is not negligible.</div></div>","PeriodicalId":246,"journal":{"name":"Applied Energy","volume":"378 ","pages":"Article 124668"},"PeriodicalIF":10.1000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0306261924020518","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

To achieve the climate goals, the energy supply system must be sourced by renewable energy instead of fossil fuels. Nevertheless, hard-to-abate sectors require negative emission technologies (NETs) to counteract their emissions. Thus, NETs play a significant role across all future scenarios considered. Since natural NETs, such as afforestation, exhibit lower scaling potential, technological approaches like Direct Air Capture (DAC) represent promising alternatives. However, DAC faces major drawbacks in terms of high energy demands and high required air mass flows due to the low CO2 concentration in ambient air (400 ppm). This results in elevated costs per captured tonne of CO2. Interestingly, the infrastructure of thermal power plants shares similarities with components of DAC units, in particular the cooling tower due to its handling of high air mass flows. As countries progressively shut down their coal-fired power plants, there is an opportunity to repurpose existing power plant infrastructure into DAC units.
Thus, this work investigates the opportunities and challenges of repurposing thermal power plant cooling towers as air contactors of DAC units with a potential of several million tonnes of CO2 captured per year. The investigation focuses on the integration of an absorption-based liquid DAC process into a wet cooling tower. Therefore, the influence of the repurposed geometry of the cooling tower and its internal packing on the operational behavior of the air contactor is analyzed for the cooling towers of the coal power Niederaußem in Germany using a two-film theory-based model. It can be observed that the repurposed geometry of the absorber enables higher air velocities due to lower pressure losses. At the same time, the reduced travel depth in cooling towers causes a lower capture rate than in geometries optimized for DAC, ultimately resulting in 50–150 tCO2/a per cooling tower. Finally, a sensitivity analysis shows that the effect of the correlations of mass transfer and volume specific surface areas is not negligible.
基于模型的电厂冷却塔再利用直接空气捕集装置热力学分析
为了实现气候目标,能源供应系统必须使用可再生能源,而不是化石燃料。然而,难以消减的部门需要负排放技术(NET)来抵消其排放。因此,负排放技术在所有未来情景中都发挥着重要作用。由于植树造林等自然负排放技术的扩展潜力较低,直接空气捕获(DAC)等技术方法是很有前途的替代方法。然而,由于环境空气中的二氧化碳浓度较低(∼400 ppm),DAC 面临着能源需求高和所需空气流量大的主要缺点。这导致每捕获一吨二氧化碳的成本增加。有趣的是,火力发电厂的基础设施与 DAC 机组的组件有相似之处,特别是冷却塔,因为它需要处理高空气质量流量。随着各国逐步关闭燃煤电厂,有机会将现有的电厂基础设施重新利用到 DAC 装置中。因此,这项工作研究了将火力发电厂冷却塔重新利用为 DAC 装置空气接触器的机遇和挑战,该装置每年可捕获数百万吨二氧化碳。调查的重点是将基于吸收的液体 DAC 工艺集成到湿式冷却塔中。因此,我们使用基于双膜理论的模型,分析了德国 Niederaußem 煤电冷却塔的冷却塔重新使用后的几何形状及其内部填料对空气接触器运行行为的影响。结果表明,由于压力损失较低,吸收器的几何形状经过重新设计后可以获得更高的气流速度。与此同时,冷却塔中的行程深度减少,导致捕集率低于为 DAC 优化的几何形状,最终导致每个冷却塔减少 50-150 tCO2/a。最后,敏感性分析表明,传质和体积比表面积的相关性影响不容忽视。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Energy
Applied Energy 工程技术-工程:化工
CiteScore
21.20
自引率
10.70%
发文量
1830
审稿时长
41 days
期刊介绍: Applied Energy serves as a platform for sharing innovations, research, development, and demonstrations in energy conversion, conservation, and sustainable energy systems. The journal covers topics such as optimal energy resource use, environmental pollutant mitigation, and energy process analysis. It welcomes original papers, review articles, technical notes, and letters to the editor. Authors are encouraged to submit manuscripts that bridge the gap between research, development, and implementation. The journal addresses a wide spectrum of topics, including fossil and renewable energy technologies, energy economics, and environmental impacts. Applied Energy also explores modeling and forecasting, conservation strategies, and the social and economic implications of energy policies, including climate change mitigation. It is complemented by the open-access journal Advances in Applied Energy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信