{"title":"Therapeutic Effect of Targeted Deployment Filling Coils in the Treatment of Intracranial Aneurysms.","authors":"Xiaoyu Ren, Bin Gao, Wangsheng Lu, Guangming Yang, Yunjie Wang, Yin Yin","doi":"10.1002/cnm.3880","DOIUrl":null,"url":null,"abstract":"<p><p>Endovascular coil embolization is the primary therapeutic modality for intracranial aneurysms. Substantial reports have been found regarding the coil packing density and inflow jet. However, the hemodynamic effect of increasing the rate of tamponade in the inflow jet area within the aneurysm remains unclear. In this study, individualized geometries of six intracranial aneurysms were recruited: all six aneurysms were located in the internal carotid artery. Two groups were created by changing the position and orientation of the microcatheter for the release of the third segment of the filling coil. The finite element method was used to simulate coil deployment. Computational fluid dynamics was used to characterize hemodynamics in post-deployment aneurysms. The parameters evaluated included velocity reduction, wall shear stress (WSS), low WSS (LWSS), relative residence time (RRT), flow kinetic energy in the neck region of the aneurysms, and residual flow volume (RFV) in the aneurysms. At the peak time (t = 0.17 s), the targeted deployment group has similar proportion of LWSS area to conventional deployment groups: targeted 78.13% ± 34.59% versus normal 74.20% ± 36.94% (mean ± SD, p = 0.583). The targeted deployment group has a higher RRT area (targeted 16.84% ± 5.58% vs. normal 6.42% ± 5.67% [mean ± SD, p = 0.009]), smaller flow kinetic energy (targeted 9.43 ± 4.33 vs. normal 16.23 ± 5.92 [mean ± SD, p = 0.047]), and a larger RFV in the aneurysms (targeted 35.97 ± 24.35 mm<sup>3</sup> vs. normal 25.80 ± 18.94 mm<sup>3</sup> [mean ± SD, p = 0.44]). Inflow jets play an important role in the treatment of aneurysms, and deploying filling coils in accordance with inflow jets may result in a better hemodynamic environment.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/cnm.3880","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Endovascular coil embolization is the primary therapeutic modality for intracranial aneurysms. Substantial reports have been found regarding the coil packing density and inflow jet. However, the hemodynamic effect of increasing the rate of tamponade in the inflow jet area within the aneurysm remains unclear. In this study, individualized geometries of six intracranial aneurysms were recruited: all six aneurysms were located in the internal carotid artery. Two groups were created by changing the position and orientation of the microcatheter for the release of the third segment of the filling coil. The finite element method was used to simulate coil deployment. Computational fluid dynamics was used to characterize hemodynamics in post-deployment aneurysms. The parameters evaluated included velocity reduction, wall shear stress (WSS), low WSS (LWSS), relative residence time (RRT), flow kinetic energy in the neck region of the aneurysms, and residual flow volume (RFV) in the aneurysms. At the peak time (t = 0.17 s), the targeted deployment group has similar proportion of LWSS area to conventional deployment groups: targeted 78.13% ± 34.59% versus normal 74.20% ± 36.94% (mean ± SD, p = 0.583). The targeted deployment group has a higher RRT area (targeted 16.84% ± 5.58% vs. normal 6.42% ± 5.67% [mean ± SD, p = 0.009]), smaller flow kinetic energy (targeted 9.43 ± 4.33 vs. normal 16.23 ± 5.92 [mean ± SD, p = 0.047]), and a larger RFV in the aneurysms (targeted 35.97 ± 24.35 mm3 vs. normal 25.80 ± 18.94 mm3 [mean ± SD, p = 0.44]). Inflow jets play an important role in the treatment of aneurysms, and deploying filling coils in accordance with inflow jets may result in a better hemodynamic environment.
期刊介绍:
All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.