Titouan P Perrin, Romane Gerey, Cédric Y M Morio, Léonard Feasson, Hugo A Kerhervé, Jeremy Rossi, Guillaume Y Millet
{"title":"Effect of Footwear Longitudinal Bending Stiffness on Energy Cost, Biomechanics, and Fatigue During a Treadmill Half-Marathon.","authors":"Titouan P Perrin, Romane Gerey, Cédric Y M Morio, Léonard Feasson, Hugo A Kerhervé, Jeremy Rossi, Guillaume Y Millet","doi":"10.1249/MSS.0000000000003599","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Introduction: Carbon plates have been used to increase running shoes' longitudinal bending stiffness (LBS), but their effect during a long duration run remains unknown. Our study aimed to identify the effect of LBS on energy cost of running (Cr), biomechanics, and fatigue during a half-marathon.Methods: Thirteen well-trained male runners (half-marathon time < 1 h40) performed two half-marathons at 95% of the running speed associated with their second ventilatory threshold on two separate visits, with either high-LBS shoes (HLBS, with carbon-plates) or standard-LBS (SLBS) shoes. Before and after the half-marathon, Cr at 12 km/h with both shoes (two 6-min bouts: Cr12) and ankle plantarflexors (PF) force were measured. During the half-marathon, running kinematics, shoe perceived comfort, and Cr were assessed.Results: During Cr12 measurements before and after the half-marathon, HLBS was 1.0 ± 2.1% more economical than SLBS (p < 0.001). During the half-marathon, Cr increased with running duration (p = 0.048) but there was no distance × condition effect. HLBS increased contact time (+3%, p = 0.01), decreased metatarsophalangeal joint dorsiflexion (-9%, p = 0.01), and was perceived less comfortable than SLBS, independently from running duration. At the end of the half-marathon, HLBS shoes led to higher PF force loss (-20.0 ± 9.8% vs -13.3 ± 11.0%, p = 0.048).Conclusions: Adding curved carbon plates in the running shoes slightly improved Cr during short running bouts at low intensity but not during a half-marathon. This discrepancy may be explained by day-to-day Cr variability and variation in shoe comfort. PF fatigue was higher with HLBS shoes but the accentuated fatigue did not further impact the biomechanical perturbations induced by the plates. Our results suggest that carbon plates alone do not provide a significant advantage for half-marathon performance.</p>","PeriodicalId":18426,"journal":{"name":"Medicine and Science in Sports and Exercise","volume":" ","pages":""},"PeriodicalIF":4.1000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine and Science in Sports and Exercise","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1249/MSS.0000000000003599","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract: Introduction: Carbon plates have been used to increase running shoes' longitudinal bending stiffness (LBS), but their effect during a long duration run remains unknown. Our study aimed to identify the effect of LBS on energy cost of running (Cr), biomechanics, and fatigue during a half-marathon.Methods: Thirteen well-trained male runners (half-marathon time < 1 h40) performed two half-marathons at 95% of the running speed associated with their second ventilatory threshold on two separate visits, with either high-LBS shoes (HLBS, with carbon-plates) or standard-LBS (SLBS) shoes. Before and after the half-marathon, Cr at 12 km/h with both shoes (two 6-min bouts: Cr12) and ankle plantarflexors (PF) force were measured. During the half-marathon, running kinematics, shoe perceived comfort, and Cr were assessed.Results: During Cr12 measurements before and after the half-marathon, HLBS was 1.0 ± 2.1% more economical than SLBS (p < 0.001). During the half-marathon, Cr increased with running duration (p = 0.048) but there was no distance × condition effect. HLBS increased contact time (+3%, p = 0.01), decreased metatarsophalangeal joint dorsiflexion (-9%, p = 0.01), and was perceived less comfortable than SLBS, independently from running duration. At the end of the half-marathon, HLBS shoes led to higher PF force loss (-20.0 ± 9.8% vs -13.3 ± 11.0%, p = 0.048).Conclusions: Adding curved carbon plates in the running shoes slightly improved Cr during short running bouts at low intensity but not during a half-marathon. This discrepancy may be explained by day-to-day Cr variability and variation in shoe comfort. PF fatigue was higher with HLBS shoes but the accentuated fatigue did not further impact the biomechanical perturbations induced by the plates. Our results suggest that carbon plates alone do not provide a significant advantage for half-marathon performance.
期刊介绍:
Medicine & Science in Sports & Exercise® features original investigations, clinical studies, and comprehensive reviews on current topics in sports medicine and exercise science. With this leading multidisciplinary journal, exercise physiologists, physiatrists, physical therapists, team physicians, and athletic trainers get a vital exchange of information from basic and applied science, medicine, education, and allied health fields.