Complex shape markers can detect alterations in the spatial distribution of cell nuclei in human lung squamous cell carcinoma: a useful tool for automatic analysis?
Ana Vitoria Ferreira Dos Santos, Renan Gabriel da Silva Ferreira, Fernanda das Chagas Angelo Mendes Tenorio, Carina Scanoni Maia, Valdemiro Amaro da Silva Junior, Romildo de Albuquerque Nogueira, Bruno Mendes Tenorio
{"title":"Complex shape markers can detect alterations in the spatial distribution of cell nuclei in human lung squamous cell carcinoma: a useful tool for automatic analysis?","authors":"Ana Vitoria Ferreira Dos Santos, Renan Gabriel da Silva Ferreira, Fernanda das Chagas Angelo Mendes Tenorio, Carina Scanoni Maia, Valdemiro Amaro da Silva Junior, Romildo de Albuquerque Nogueira, Bruno Mendes Tenorio","doi":"10.1007/s00418-024-02336-3","DOIUrl":null,"url":null,"abstract":"<p><p>Lung cancer is the leading cause of cancer-related death. The use of computational methods to quantify changes that are not perceptible to the human eye is increasing in digital pathology imaging and has quickly improved detection rates at a low cost. Therefore, the present study aims to use complex computational shape markers as tools for automated analysis of the spatial distribution of cells in microscopy images of squamous cell lung carcinoma (SqCC). Photomicrographs from pathology glass slides in the LC25000 dataset were used in this study. Compared with those of the control, the fractal dimension (28%) and lacunarity (41%) of the cell nuclei changed in SqCC. The multifractal analysis revealed a significant difference in parameters Dq, α, and f(α) for all values of q (-10 to + 10), with a greater increase for more positive q values. The values at q + 10 increased by 34% for Dq, 36% for α, and 53% for f(α) in the SqCC images. The circularity, area, and perimeter also changed in the SqCC images. However, the parameters of aspect ratio, roundness, and solidity did not significantly differ between SqCC and benign tissue. The complex shape markers with the greatest changes in this study were the f(α) values for multifractality (53%) and lacunarity (41%). In conclusion, automated quantification of the spatial distribution of cell nuclei can be a fast, low-cost tool for evaluating the microscopic characteristics of SqCC; therefore, complex shape markers could be useful tools for software and artificial intelligence to detect lung carcinoma.</p>","PeriodicalId":13107,"journal":{"name":"Histochemistry and Cell Biology","volume":"163 1","pages":"1"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Histochemistry and Cell Biology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1007/s00418-024-02336-3","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CELL BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Lung cancer is the leading cause of cancer-related death. The use of computational methods to quantify changes that are not perceptible to the human eye is increasing in digital pathology imaging and has quickly improved detection rates at a low cost. Therefore, the present study aims to use complex computational shape markers as tools for automated analysis of the spatial distribution of cells in microscopy images of squamous cell lung carcinoma (SqCC). Photomicrographs from pathology glass slides in the LC25000 dataset were used in this study. Compared with those of the control, the fractal dimension (28%) and lacunarity (41%) of the cell nuclei changed in SqCC. The multifractal analysis revealed a significant difference in parameters Dq, α, and f(α) for all values of q (-10 to + 10), with a greater increase for more positive q values. The values at q + 10 increased by 34% for Dq, 36% for α, and 53% for f(α) in the SqCC images. The circularity, area, and perimeter also changed in the SqCC images. However, the parameters of aspect ratio, roundness, and solidity did not significantly differ between SqCC and benign tissue. The complex shape markers with the greatest changes in this study were the f(α) values for multifractality (53%) and lacunarity (41%). In conclusion, automated quantification of the spatial distribution of cell nuclei can be a fast, low-cost tool for evaluating the microscopic characteristics of SqCC; therefore, complex shape markers could be useful tools for software and artificial intelligence to detect lung carcinoma.
期刊介绍:
Histochemistry and Cell Biology is devoted to the field of molecular histology and cell biology, publishing original articles dealing with the localization and identification of molecular components, metabolic activities and cell biological aspects of cells and tissues. Coverage extends to the development, application, and/or evaluation of methods and probes that can be used in the entire area of histochemistry and cell biology.